Mixed reality holograms for percutaneous lead extraction of cardiac implantable electronic devices

被引:1
|
作者
Valverde, Israel [1 ,2 ,3 ,8 ]
Gomez, Gorka [1 ]
Gonzalez, Aristides de Alarcon [4 ]
Sierra, Antonio [5 ]
Perez, Adriano [5 ]
Hussain, Tarique [6 ]
Pushparajah, Kuberan [3 ]
Ordonez, Antonio [1 ]
Carretero, Encarnacion Gutierrez [1 ,7 ]
机构
[1] Univ Seville, Inst Biomed Seville IBiS, Fabricat Lab, Cardiovasc Pathophysiol Grp,HUVR,CSIC, Seville, Spain
[2] Hosp Infantil Virgen del Rocio, Pediat Cardiol Unit, Seville 41013, Spain
[3] Kings Coll London, Sch Biomed Engn & Imaging Sci, London, England
[4] Univ Seville, Hosp Univ Virgen del Rocio, CSIC,Grp Resistencias Bacterianas & Antimicrobiano, Inst Biomed Sevilla IBIS,Dept Hematol,Unidad Clin, Seville 41013, Spain
[5] VR AR MR & Adv Interfaces Team, Seville, Spain
[6] UT Southwestern Med Ctr, Dept Pediat, Dallas, TX USA
[7] Hosp Univ Virgen del Rocio, Dept Cardiovasc Surg, Seville, Spain
[8] Hosp Sick Children, Labatt Family Heart Ctr, Div Cardiol, Toronto, ON, Canada
关键词
Mixed reality; Holograms; Augmented reality; Percutaneous lead extraction; RISK STRATIFICATION; DEFIBRILLATOR; COMPLICATIONS; SURGERY; MODELS;
D O I
10.1007/s10055-023-00929-2
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
To assess the potential of mixed reality holograms (MixR) based on CT images to improve percutaneous lead extraction (PLE) planning and intraoperative assistance. This was a prospective, controlled, single-centre study. Five patients with CIED infection for PLE were included in the study. Conventional imaging (chest radiograph and CT) and MixR holograms were evaluated for preoperative planning to identify common complications such as vascular thrombosis, broken leads, loops, kinking, fibrosis along the wires, and perforation of cardiovascular structures. The degree of difficulty of the procedure was estimated based on potential complications. After the PLE procedure, the level of concordance between conventional imaging and MixR holograms with intraoperative findings was evaluated. The utility of MixR intraoperative guidance was also assessed. MixR holograms demonstrated a very high correlation in predicting the presence of loops, kinking, and fibrosis compared to conventional imaging, which showed a low-to-high correlation. MixR also showed a high correlation in estimating the degree of difficulty of the procedure compared to conventional imaging, which tended to underestimate it. The surgeon who performed the PLE agreed that MixR was helpful during intraoperative assistance. MixR holograms based on CT images are an effective tool for understanding cardiovascular anatomy and detecting potential areas of complications. MixR may be used as a complementary tool for both preoperative planning and intraoperative assistance in PLE procedures.Graphical abstractMixed reality holograms for intraprocedural intervention assistance.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] EFFICACY AND FEASIBILITY OF CARDIOVASCULAR IMPLANTABLE ELECTRONIC DEVICES LEAD EXTRACTION IN ELDERLY PATIENTS
    Nagashima, M.
    Goya, M.
    Soga, Y.
    Hiroshima, K.
    Hayashi, K.
    Ohe, M.
    Makihara, Y.
    Niu, H.
    Ando, K.
    Iwabuchi, M.
    Nobuyoshi, M.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 : S137 - S138
  • [22] Costs and complications associated with transvenous lead reoperation in cardiac implantable electronic devices
    Griffiths, Robert, I
    Amorosi, Stacey L.
    Jacobsen, Caroline M.
    McBee, Patrick J.
    Menzin, Joseph
    Reynolds, Matthew R.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (02) : 503 - 511
  • [23] Cardiac implantable electronic devices: Leads can lead to tricuspid regurgitation and death!
    Dreyfus, Julien
    Messika-Zeitoun, David
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2023, 372 : 91 - 92
  • [24] Comprehensive strategy to reduce the incidence of lead dislodgement for cardiac implantable electronic devices
    Afzal, Muhammad R.
    Horner, Sarah
    Matre, Nancy B.
    Blake, Patricia
    Dunham, Kari
    Pinkhas, Daniel
    Okabe, Toshimasa
    Tyler, Jaret
    Houmsse, Mahmoud
    Kalbfleisch, Steven J.
    Weiss, Raul
    Hummel, John D.
    Daoud, Emile G.
    Augostini, Ralph S.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (01): : 58 - 62
  • [25] COMPREHENSIVE STRATEGY TO REDUCE THE INCIDENCE OF LEAD DISLODGMENT FOR CARDIAC IMPLANTABLE ELECTRONIC DEVICES
    Afzal, Muhammad Rizwan
    Matre, Nancy
    Horner, Sarah
    Patel, Dilesh
    Houmsse, Mahmoud
    Daoud, Emile
    Kalbfleisch, Steven
    Tyler, Jaret
    Okabe, Toshimasa
    Hummel, John
    Weiss, Raul
    Augostini, Ralph
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 391 - 391
  • [26] Cybersecurity and cardiac implantable electronic devices
    Alexander, Bryce
    Baranchuk, Adrian
    NATURE REVIEWS CARDIOLOGY, 2020, 17 (06) : 315 - 317
  • [27] Innovations in Cardiac Implantable Electronic Devices
    Khan, Khurrum
    Kim, Jitae A.
    Gurgu, Andra
    Khawaja, Muzamil
    Cozma, Dragos
    Chelu, Mihail G.
    CARDIOVASCULAR DRUGS AND THERAPY, 2022, 36 (04) : 763 - 775
  • [28] Cybersecurity and cardiac implantable electronic devices
    Bryce Alexander
    Adrian Baranchuk
    Nature Reviews Cardiology, 2020, 17 : 315 - 317
  • [29] Cardiac implantable electronic devices and cybersecurity
    Patel, Bhakti
    Makaryus, Amgad N.
    EXPERT REVIEW OF MEDICAL DEVICES, 2021, 18 (18) : 69 - 77
  • [30] Innovations in Cardiac Implantable Electronic Devices
    Khurrum Khan
    Jitae A. Kim
    Andra Gurgu
    Muzamil Khawaja
    Dragos Cozma
    Mihail G. Chelu
    Cardiovascular Drugs and Therapy, 2022, 36 : 763 - 775