Clinical Utility of CT-based Attenuation-correction in Myocardial Perfusion SPECT Imaging

被引:0
|
作者
Hatipoglu, Filiz [1 ]
Cetin, Neslihan [2 ]
机构
[1] Ataturk Training & Res Hosp, Clin Nucl Med, Izmir, Turkiye
[2] Umraniye Training & Res Hosp, Clin Nucl Med, Istanbul, Turkiye
关键词
Myocardial perfusion; scintigraphy; attenuation correction; COMPUTED-TOMOGRAPHY; DIAGNOSTIC PERFORMANCE; TASK-FORCE; ARTIFACTS; SCATTER; GUIDELINES; COMMITTEE; ACCURACY; HEART; TRIAL;
D O I
10.4274/mirt.galenos.2022.68094
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: We aimed to investigate and compare the role of computed tomography (CT)-based attenuation-corrected images (AC) with non -attenuation-corrected images (NAC) obtained by single-photon emission computed tomography/computed tomography (SPECT/CT) myocardial perfusion imaging (MPI).Methods: The data of 124 patients who were applied one-day stress-rest Tc-99m sestamibi SPECT/CT MPI and who had coronary angiography (CAG) results within & PLUSMN;3 months were retrospectively reviewed. AC and NAC images were visually evaluated by two nuclear medicine specialists in a consensus. CAG results were used as the reference standard.Results: Specificity, sensitivity, and accuracy were calculated as 66%, 61%, 71%, 79% and 69%, 70% for AC and NAC imaging in the whole group, respectively. There was no statistically significant difference between AC and NAC images for specificity, sensitivity, and accuracy in the male and female subgroups. In the diagnosis of right coronary artery (RCA) disease, CT AC significantly increased the specificity from 87% to 96%. However, in the left anterior descending artery (LAD) region, the specificity was significantly reduced from 95% to 77%. Conclusion: CT-based AC did not significantly contribute to diagnostic performance for increased specificity for the RCA and reduced specificity in the LAD region. Therefore, AC images should always be evaluated side by side with NAC images to benefit from the different advantages of both techniques.
引用
收藏
页码:138 / 145
页数:8
相关论文
共 50 条
  • [11] Impact of attenuation correction in G-SPECT myocardial perfusion imaging interpretation: results of the multicenter SPAG (SPect Attenuation-correction vs Gated) study
    Genovesi, D.
    Giorgetti, A.
    Gimelli, A.
    Cannizzaro, G.
    Bertagna, F.
    Rossi, M.
    Romeo, A.
    Bonini, R.
    Marzullo, P.
    EUROPEAN HEART JOURNAL, 2010, 31 : 578 - 578
  • [12] Usefulness of attenuation correction in G-SPECT myocardial perfusion imaging interpretation: results of the multicenter SPAG (SPect Attenuation-correction vs Gated) study
    Genovesi, D.
    Giorgetti, A.
    Gimelli, A.
    Cannizzaro, G.
    Giubbini, R.
    Bertagna, F.
    Fagioli, G.
    Rossi, M.
    Bonini, R.
    Marzullo, P.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A93 - A94
  • [13] What is the benefit of CT-based attenuation correction in myocardial perfusion SPET?
    Apostolopoulos, Dimitrios J.
    Savvopoulos, Christos
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2016, 19 (02): : 89 - 92
  • [14] The effect of CT-based attenuation correction on the automatic perfusion score of myocardial perfusion imaging using a dedicated cardiac solid-state CZT SPECT/CT
    Kennedy, John A.
    Brodov, Yafim
    Weinstein, Adam L.
    Israel, Ora
    Frenkel, Alex
    JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (01) : 236 - 245
  • [15] The effect of CT-based attenuation correction on the automatic perfusion score of myocardial perfusion imaging using a dedicated cardiac solid-state CZT SPECT/CT
    John A. Kennedy
    Yafim Brodov
    Adam L. Weinstein
    Ora Israel
    Alex Frenkel
    Journal of Nuclear Cardiology, 2019, 26 : 236 - 245
  • [16] Attenuation-correction does not improve quantitative diagnostic performance of myocardial perfusion SPECT in women
    Wolak, Arik
    Slomka, Piotr J.
    Fish, Mathews B.
    Gerlach, James
    Lorenzo, Santiago
    Berman, Daniel S.
    Germano, Guido
    CIRCULATION, 2007, 116 (16) : 344 - 344
  • [17] Dose reduction of CT-based attenuation correction in myocardial perfusion CZT-SPECT using iterative CT reconstruction
    van Dalen, J.
    van Osch, J.
    Mouden, M.
    Timmer, J.
    Ottervanger, J.
    Reiffers, S.
    Knollema, S.
    Jager, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S222 - S222
  • [18] Would SPECT/CT be a must for attenuation correction in gated-SPECT myocardial perfusion imaging?
    Ali, L.
    Al-Saffar, A.
    Loutfi, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S533 - S533
  • [19] Clinical utility of attenuation correction with X-rays in myocardial perfusion SPECT studies
    Bajen, M. T.
    Ricart, Y.
    Rodriguez-Gasen, A.
    Mora, J.
    Quintana, M. E.
    Benitez, A.
    Domenech, A.
    Ruiz-Mayoral, A.
    Puchala, R.
    Pallares, C.
    Martin-Comin, J.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR, 2007, 26 (06): : 359 - 366
  • [20] Sources of attenuation-correction artefacts in cardiac PET/CT and SPECT/CT
    McQuaid, Sarah J.
    Hutton, Brian F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (06) : 1117 - 1123