Noninvasive fluid bubble detection based on capacitive micromachined ultrasonic transducers

被引:3
|
作者
Yuan, Jiawei [1 ,2 ]
Li, Zhikang [1 ,2 ,3 ]
Ma, Qi [1 ,2 ]
Li, Jie [1 ,2 ,4 ]
Li, Zixuan [1 ,2 ]
Zhao, Yihe [1 ,2 ]
Qin, Shaohui [1 ,2 ]
Shi, Xuan [1 ,2 ]
Zhao, Libo [1 ,2 ,3 ]
Yang, Ping [1 ,2 ,3 ]
Luo, Guoxi [1 ,2 ,3 ]
Wang, Xiaozhang [1 ,2 ]
Teh, Kwok Siong [5 ]
Jiang, Zhuangde [1 ,2 ,3 ]
机构
[1] Xi An Jiao Tong Univ, Yantai Res Inst Intelligent Sensing Technol & Syst, State Key Lab Mfg Syst Engn, Int Joint Lab Micro Nano Mfg & Measurement Technol, Xian 710049, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Mech Engn, Xian 710049, Peoples R China
[3] Shandong Lab Yantai Adv Mat & Green Mfg, Yantai 265503, Peoples R China
[4] Shaanxi Univ Sci & Technol, Sch Mech & Elect Engn, Xian 710049, Peoples R China
[5] San Francisco State Univ, Sch Engn, San Francisco, CA 94132 USA
基金
中国国家自然科学基金;
关键词
FLOW; SENSOR; FABRICATION; TOMOGRAPHY; VELOCITY; SYSTEM;
D O I
10.1038/s41378-023-00491-6
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Ultrasonic fluid bubble detection is important in industrial controls, aerospace systems and clinical medicine because it can prevent fatal mechanical failures and threats to life. However, current ultrasonic technologies for bubble detection are based on conventional bulk PZT-based transducers, which suffer from large size, high power consumption and poor integration with ICs and thus are unable to implement real-time and long-term monitoring in tight physical spaces, such as in extracorporeal membrane oxygenation (ECMO) systems and dialysis machines or hydraulic systems in aircraft. This work highlights the prospect of capacitive micromachined ultrasonic transducers (CMUTs) in the aforementioned application situations based on the mechanism of received voltage variation caused by bubble-induced acoustic energy attenuation. The corresponding theories are established and well validated using finite element simulations. The fluid bubbles inside a pipe with a diameter as small as 8 mm are successfully measured using our fabricated CMUT chips with a resonant frequency of 1.1 MHz. The received voltage variation increases significantly with increasing bubble radii in the range of 0.5-2.5 mm. Further studies show that other factors, such as bubble positions, flow velocities, fluid medium types, pipe thicknesses and diameters, have negligible effects on fluid bubble measurement, demonstrating the feasibility and robustness of the CMUT-based ultrasonic bubble detection technique.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Lamb wave devices based on Capacitive Micromachined Ultrasonic Transducers
    Badi, MH
    Yaralioglu, GG
    Ergun, AS
    Hansen, ST
    Khuri-Yakub, BT
    2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 1031 - 1034
  • [22] Capacitive micromachined ultrasonic transducers leak detection by dye penetrant test
    Nowodzinski, A.
    Ndjoye-Kogou, O.
    Mourier, V.
    Nonglaton, G.
    Bouchu, D.
    Fain, B.
    Giroud, S.
    MICROELECTRONICS RELIABILITY, 2020, 114
  • [23] CAPACITIVE MICROMACHINED ULTRASONIC TRANSDUCERS FOR BIOCHEMICAL DETECTION WITH FLEXIBLE HIGH SENSITIVITY
    Zhao, Yihe
    Lu, Dejiang
    Zhao, Libo
    Xia, Yong
    Li, Zhikang
    Li, Jie
    Zhang, Jiawang
    Jia, Chen
    Wang, Jiuhong
    Jiang, Zhuangde
    2018 IEEE MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2018, : 924 - 927
  • [24] Capacitive micromachined ultrasonic transducers: Theory and technology
    Ergun, A.S. (sanli@stanford.edu), 1600, American Society of Civil Engineers (16):
  • [25] Dynamic analysis of capacitive micromachined ultrasonic transducers
    Bayram, B
    Yaralioglu, GG
    Kupnik, M
    Ergun, AS
    Oralkan, Ö
    Nikoozadeh, A
    Khuri-Yakub, BT
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (12) : 2270 - 2275
  • [26] Noninvasive Stress Detection Based on Piezoelectric Micromachined Ultrasonic Transducers for Bolt Loosening Warning
    Li, Zhikang
    Li, Jiazhu
    Zhao, Yihe
    Li, Zixuan
    Shi, Xuan
    Qin, Shaohui
    Li, Jie
    Yuan, Jiawei
    Ma, Qi
    Zhao, Zilong
    Zhang, Shiwang
    Yuan, Zheng
    Wang, Xiaozhang
    Zhao, Libo
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 16
  • [27] Capacitive Micromachined Ultrasonic Transducers: Technology and Application
    Salim, Muhammed Sabri
    Malek, M. F. Abd
    Heng, R. B. W.
    Juni, K. M.
    Sabri, Naseer
    JOURNAL OF MEDICAL ULTRASOUND, 2012, 20 (01) : 8 - 31
  • [28] Capacitive micromachined ultrasonic transducers: Theory and technology
    Ergun, AS
    Yaralioglu, GG
    Khuri-Yakub, BT
    JOURNAL OF AEROSPACE ENGINEERING, 2003, 16 (02) : 76 - 84
  • [29] Surface micromachined capacitive ultrasonic immersion transducers
    Jin, XC
    Ladabaum, I
    Khuri-Yakub, BT
    MICRO ELECTRO MECHANICAL SYSTEMS - IEEE ELEVENTH ANNUAL INTERNATIONAL WORKSHOP PROCEEDINGS, 1998, : 649 - 654
  • [30] Experimental characterization of capacitive micromachined ultrasonic transducers
    Olcum, Selim
    Atalar, Abdullah
    Koymen, Hayerttin
    Oguz, Kagan
    Senlik, Muhammed N.
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 2131 - 2134