A microfluidic chip-based multiplex PCR-reverse dot blot hybridization technique for rapid detection of enteropathogenic bacteria

被引:3
|
作者
Hu, Xinyi [1 ,2 ]
Lin, Chunhui [1 ,2 ]
Li, Ge [1 ,2 ]
Jiang, Tong [1 ,2 ]
Shen, Jilu [1 ,2 ]
机构
[1] Anhui Med Univ, Affiliated Hosp 1, Hefei 230022, Anhui, Peoples R China
[2] Anhui Publ Hlth Clin Ctr, Hefei 230012, Anhui, Peoples R China
关键词
Enteropathogenic bacteria; Infectious diarrhea; Micro-fluidic chip; Reverse dot blot hybridization; SALMONELLA; CAMPYLOBACTER; DIAGNOSTICS; MORBIDITY; DISEASES;
D O I
10.1016/j.mimet.2023.106785
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Diarrhea caused by enteropathogenic bacteria is a major public health issue worldwide, especially in developing countries. In this study, a microfluidic chip-based multiplex polymerase chain reaction (PCR)-reverse dot blot hybridization technology for the rapid and simultaneous detection of 11 enteropathogenic bacteria was developed and the entire process was completed within 3-4 h. The specificity of this method was analyzed using 11 types of pure target bacterial colonies and another 7 types of pure bacterial colonies, and its sensitivity was evaluated with the serial 10-fold dilution of 11 types of pure target bacterial colonies. The detection limit of this method was as low as 103-102 CFU/mL, and it exhibited high specificity for enteropathogenic bacteria. A total of 60 clinical diarrheal fecal samples were detected using this method, the results of which were compared with those of the conventional reference method, which resulted in a positive coincident rate of 100% and a negative coincident rate of 93.75%. Based on the findings, it could be concluded that multiplex PCR-reverse dot blot hybridization based on the microfluidic chip is a rapid, economical, sensitive, specific, and high-throughput method for detecting enteropathogenic bacteria.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Rapid Detection of Rifampin-resistant Clinical Isolates of Mycobacterium tuberculosis by Reverse Dot Blot Hybridization
    GUO Qian
    YU Yan
    ZHU Yan Ling
    ZHAO Xiu Qin
    LIU Zhi Guang
    ZHANG Yuan Yuan
    LI Gui Lian
    WEI Jian Hao
    WU Yi Mou
    WAN Kang Lin
    Biomedical and Environmental Sciences, 2015, 28 (01) : 25 - 35
  • [22] Ultrafast PCR Detection of COVID-19 by Using a Microfluidic Chip-Based System
    Chen, Xiaojing
    Liu, Yiteng
    Zhan, Xuan
    Gao, Yibo
    Sun, Zhongyi
    Wen, Weijia
    Zheng, Weidong
    BIOENGINEERING-BASEL, 2022, 9 (10):
  • [23] Validation of PCR-reverse line blot, a method for rapid detection and identification of nine dermatophyte species in nail, skin and hair samples
    Bergmans, A. M. C.
    Schoulis, L. M.
    van der Ent, M.
    Klaassen, A.
    Bohm, N.
    Wintermans, R. G. F.
    CLINICAL MICROBIOLOGY AND INFECTION, 2008, 14 (08) : 778 - 788
  • [24] PCR-reverse dot blot human papillomavirus genotyping as a primary screening test for cervical cancer in a hospital-based cohort
    Kang, Yafang
    Sun, Pengming
    Mao, Xiaodan
    Dong, Binhua
    Ruan, Guanyu
    Chen, Lihua
    JOURNAL OF GYNECOLOGIC ONCOLOGY, 2019, 30 (03)
  • [25] Rapid detection and typing of human papillomavirus in tumor tissue by reverse dot blot technique.
    Qi, FJ
    Xu, QA
    Huang, YZ
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 1998, 25 (01) : 75 - 78
  • [26] Detection of unknown deletions in beta-globin gene cluster using PCR-reverse dot-blot method in prenatal diagnosis
    Liao, Can
    Li, Dong-Zhi
    EUROPEAN JOURNAL OF HAEMATOLOGY, 2009, 83 (04) : 385 - 386
  • [27] A multiplex PCR-based reverse line blot hybridization (mPCR/RLB) assay for detection of bacterial respiratory pathogens in children with pneumonia
    Wang, Yajuan
    Kong, Fanrong
    Yang, Yonghong
    Gilbert, Gwendolyn L.
    PEDIATRIC PULMONOLOGY, 2008, 43 (02) : 150 - 159
  • [28] A disposable and cost efficient microfluidic device for the rapid chip-based electrical detection of DNA
    Schueler, Thomas
    Kretschmer, Robert
    Jessing, Sven
    Urban, Matthias
    Fritzsche, Wolfgang
    Moeller, Robert
    Popp, Juergen
    BIOSENSORS & BIOELECTRONICS, 2009, 25 (01): : 15 - 21
  • [29] Multiplex and on-site PCR detection of swine diseases based on the microfluidic chip system
    Yan Jiang
    Shan Jiang
    Yue Wu
    Bin Zhou
    Kaimin Wang
    Luyan Jiang
    Yunfeng Long
    Gan Chen
    Dexin Zeng
    BMC Veterinary Research, 17
  • [30] Multiplex and on-site PCR detection of swine diseases based on the microfluidic chip system
    Jiang, Yan
    Jiang, Shan
    Wu, Yue
    Zhou, Bin
    Wang, Kaimin
    Jiang, Luyan
    Long, Yunfeng
    Chen, Gan
    Zeng, Dexin
    BMC VETERINARY RESEARCH, 2021, 17 (01)