Does Lumbar Interbody Fusion Modality Affect the Occurrence of Complications in an Osteoporotic Spine Under Whole-Body Vibration? A Finite Element Study

被引:1
|
作者
Zeng, Qiuhong [1 ]
Liao, Yi [1 ]
Pou, Kuokchon [1 ]
Chen, Qian [1 ]
Li, Yixuan [1 ]
Cai, Lulu [1 ]
Huang, Zhen [1 ]
Tang, Shujie [1 ]
机构
[1] Jinan Univ, Sch Chinese Med, Guangzhou, Peoples R China
关键词
-Anterior lumbar interbody fusion (ALIF); -Osteoporosis (OP); -Posterior lumbar interbody fusion (PLIF); Transforaminal lumbar interbody fusion (TLIF); Whole-body vibration (WBV); POSTERIOR; SEGMENT; DEGENERATION; ANTERIOR; SURGERY; STRESS;
D O I
10.1016/j.wneu.2023.05.053
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: To evaluate the effects of 3 lumbar interbody fusion techniques on the occurrence of complications in an osteoporotic spine under whole-body vibration.METHODS: A previously developed and validated nonlinear finite element model of L1-S1was modified to develop anterior lumbar interbody fusion (ALIF), posterior lumbar interbody fusion (PLIF), and transforaminal lumbar interbody fusion (TLIF) models with osteoporosis. In each model, the lower surface of the sacrum was absolutely fixed, a follower load of 400N was applied through the axis of the lumbar spine, and an axial sinusoidal vertical load of & PLUSMN;40N (5 Hz) was imposed on the superior surface of L1, to perform a transient dynamic analysis. The maximal values of intradiscal pressure, shear stress on annulus substance, disc bulge, facet joint stress, and screw and rod stress, along with their dynamic response curves, were collected.RESULTS: Among these 3 models, the TLIF model generated the greatest screw and rod stress, and the PLIF model generated the greatest cageebone interface stress. At the L3-L4 level, compared with the other 2 models, the maximal values and dynamic response curves of intradiscal pressure, shear stress of annulus ground substance, and disc bulge were all lower in the ALIF model. However, the facet contact stress at the adjacent segment in the ALIF model was higher than that in the other 2 models. CONCLUSIONS: In an osteoporotic spine under whole body vibration, TLIF has the highest risk of screw and rod breakage, PLIF has the highest risk of cage subsidence, and ALIF has the lowest risk of upper adjacent disc degeneration, but the highest risk of adjacent facet joint degeneration.
引用
收藏
页码:E297 / E305
页数:9
相关论文
共 30 条
  • [21] Comparison of cage application modality in posterior lumbar interbody fusion with posterior instrumentation-A finite element study
    Tsuang, Yang-Hwei
    Chiang, Yueh-Feng
    Hung, Chih-Yi
    Wei, Hung-Wen
    Huang, Chang-Hung
    Cheng, Cheng-Kung
    MEDICAL ENGINEERING & PHYSICS, 2009, 31 (05) : 565 - 570
  • [22] Effect of Osteoporosis on Adjacent Segmental Degeneration After Posterior Lumbar Interbody Fusion Under Whole Body Vibration
    Zhang, Renwen
    Zhang, Chenchen
    Shu, Xinnong
    Yuan, Xin
    Li, Yixuan
    Chen, Qian
    Huang, Honghao
    Zeng, Qiuhong
    Bu, Guojun
    Li, Ruihui
    Li, Shuyu
    Chang, Minmin
    Tang, Shujie
    WORLD NEUROSURGERY, 2021, 152 : E700 - E707
  • [23] Stability Evaluation of Different Oblique Lumbar Interbody Fusion Constructs in Normal and Osteoporotic Condition - A Finite Element Based Study
    Bereczki, Ferenc
    Turbucz, Mate
    Kiss, Rita
    Eltes, Peter Endre
    Lazary, Aron
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [24] The effect of non-fusion dynamic stabilization on biomechanical responses of the implanted lumbar spine during whole-body vibration
    Fan, Wei
    Guo, Li-Xin
    Computer Methods and Programs in Biomedicine, 2020, 192
  • [25] Does anterior lumbar interbody fusion promote adjacent degeneration in degenerative disc disease? A finite element study
    Tang, Shujie
    Rebholz, Brandon J.
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2011, 16 (02) : 221 - 228
  • [26] Association between occupational exposure to whole-body vibration and disc-related diseases of the lumbar spine - Evaluations within the German Spine Study
    Bergmann, Annekatrin
    Seidler, Andreas
    Schumann, Barbara
    Fischer, Siegfried
    Bolm-Audorff, Ulrich
    Ditchen, Dirk
    Ellegast, Rolf
    Elsner, Gine
    Grifka, Joachim
    Hinz, Barbara
    Hofmann, Friedrich
    Jager, Matthias
    Linhardt, Oliver
    Luttmann, Alwin
    Michaelis, Martina
    Petereit-Haack, Gabriela
    Haerting, Johannes
    ZENTRALBLATT FUR ARBEITSMEDIZIN ARBEITSSCHUTZ UND ERGONOMIE, 2007, 57 (10): : 317 - 327
  • [27] Does short-term whole-body vibration training affect arterial stiffness in chronic stroke? A preliminary study
    Yule, Christie E.
    Stoner, Lee
    Hodges, Lynette D.
    Cochrane, Darryl J.
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2016, 28 (03) : 996 - 1002
  • [28] Impact of sacroiliac interosseous ligament tension and laxity on lumbar spine biomechanics under vertical vibration: a finite element study
    Yu, Shihong
    Zheng, Shifu
    Gao, Ying
    Liu, Yitang
    Zhang, Kaifeng
    Dong, Ruichun
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024,
  • [29] Measures of internal lumbar load in professional drivers - the use of a whole-body finite-element model for the evaluation of adverse health effects of multi-axis vibration
    Schust, Marianne
    Menzel, Gerhard
    Hofmann, Joerg
    Forta, Nazim Gizem
    Pinto, Iole
    Hinz, Barbara
    Bovenzi, Massimo
    ERGONOMICS, 2015, 58 (07) : 1191 - 1206
  • [30] The effect of polymethylmethacrylate augmentation on the primary stability of stand-alone implant construct versus posterior stabilization in oblique lumbar interbody fusion with osteoporotic bone quality- a finite element study
    Bereczki, Ferenc
    Turbucz, Mate
    Pokorni, Agoston Jakab
    Hajnal, Benjamin
    Ronai, Marton
    Klemencsics, Istvan
    Lazary, Aron
    Eltes, Peter Endre
    SPINE JOURNAL, 2024, 24 (07): : 1323 - 1333