Laser Induced Breakdown Spectroscopy (LIBS) for whole rock geochemistry

被引:7
|
作者
Fontana, Fernando F. [1 ,6 ]
van der Hoek, Ben [1 ,2 ]
Tassios, Steven [2 ,3 ]
Tiddy, Caroline [1 ,2 ]
Stromberg, Jessica [2 ,4 ]
Francis, Neil [2 ,4 ]
Uvarova, Yulia A. [2 ,4 ]
Lancaster, David G. [5 ]
机构
[1] Univ South Australia, Future Ind Inst, UniSA STEM, Mawson Lakes, SA 5000, Australia
[2] Mineral Explorat Cooperat Res Ctr MinEx CRC, Mawson Lakes, SA 5000, Australia
[3] CSIRO, Mineral Resources, Gate 1,Normanby Rd, Clayton, Vic 3169, Australia
[4] CSIRO, ARRC Australia Resources Res Ctr, Mineral Resources, POB 1130, Bentley, WA 6102, Australia
[5] Univ South Australia, Laser Phys & Photon Devices Lab, UniSA STEM, Mawson Lakes, SA 5000, Australia
[6] Univ South Australia, Future Ind Inst, Bldg X, Mawson Lakes, SA 5095, Australia
关键词
Laser-Induced Breakdown Spectroscopy; Geochemistry; Downhole analysis; Mineral exploration; MINERALS; LIMITS;
D O I
10.1016/j.gexplo.2023.107160
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
To meet the ever-increasing global demand for metals, new mineral deposits need to be discovered. However, as the exploration frontier progressively moves towards deeper buried prospective areas, sampling is becoming costlier and deposit discovery rates are in decline. New technologies and analytical procedures able to deliver fast, reliable, and cheaper samples, analysis, and data, compared to current procedures are therefore, crucial in decreasing the risk of exploration targeting and can represent a step change in mineral exploration. In this study we demonstrate how to emulate laboratory whole-rock geochemical data for major elements (Al, Ca, Fe, K, Mg, Na, Si, and Ti) by averaging LIBS spot analyses performed over single, 1-mm spaced transects, that imitate downhole trajectories, along similar to 1-meter length drill core intervals for chemically, texturally, and mineralogically diverse rocks. Data was collected using a benchtop prototype LIBS instrument that could be reconfigured to fit within a >= 75 mm diameter drill hole. The prototype comprises a customised 8 ns pulsed 532 nm Nd:YAG laser with maximum pulse energy of 40 mJ at 5 Hz; two high-resolution spectrometers that together cover a spectral range from 190 to 830 nm, hence allowing all elements to be analysed; a motorised stage; and optics. Estimated LIBS geochemistry shows strong correlations with laboratory whole rock geochemistry for the selected major elements, particularly for Si, Al, and Na, and to a lesser extent K, although the LIBS estimation can breakdown for elements found in low concentrations (e.g., 0.06 wt%). Factors including the variability in mineralogy and element deportment, or roughness of the analysed surface can result in under- or over-estimation in LIBS whole rock geochemistry. In addition, for more efficient data collection processes, investigations of the optimal number of LIBs spot analysis showed that optimal similar to 30 to similar to 560 spot analyses per meter are required to emulate whole rock geochemistry (e.g., 1 % error and 95 % confidence). The strongest influence on the optimal number of LIBS analysis required for estimation of whole rock geochemistry is the range of element concentration and to a lesser extent the number of minerals that host an element as well as grain size. The results of this study show promise in development of strategies for rapid whole rock geochemical analysis down a drill hole.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Composition analysis of medieval ceramics by laser-induced breakdown spectroscopy (LIBS)
    B. Genc Oztoprak
    M. A. Sinmaz
    F. Tülek
    Applied Physics A, 2016, 122
  • [42] A Method for Resolving Overlapped Peaks in Laser-Induced Breakdown Spectroscopy (LIBS)
    Zhang, Bo
    Yu, Haibin
    Sun, Lanxiang
    Xin, Yong
    Cong, Zhibo
    APPLIED SPECTROSCOPY, 2013, 67 (09) : 1087 - 1097
  • [43] Soil Metals Analysis Using Laser-Induced Breakdown Spectroscopy (LIBS)
    Essington, Michael E.
    Melnichenko, Galina V.
    Stewart, Melanie A.
    Hull, Robert A.
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2009, 73 (05) : 1469 - 1478
  • [44] Laser-induced plasma and laser-induced breakdown spectroscopy (LIBS) in China: The challenge and the opportunity
    Yu, Jin
    Zheng, Ronger
    FRONTIERS OF PHYSICS, 2012, 7 (06) : 647 - 648
  • [45] Application of Handheld Laser-Induced Breakdown Spectroscopy (LIBS) to Geochemical Analysis
    Connors, Brendan
    Somers, Andrew
    Day, David
    APPLIED SPECTROSCOPY, 2016, 70 (05) : 810 - 815
  • [46] Rapid analysis of coal properties by laser-induced breakdown spectroscopy (LIBS)
    Gaelli, Markus
    Robinsky, Robert
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248
  • [47] Composition analysis of medieval ceramics by laser-induced breakdown spectroscopy (LIBS)
    Oztoprak, B. Genc
    Sinmaz, M. A.
    Tulek, F.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2016, 122 (05):
  • [48] Measuring total soil carbon with laser-induced breakdown spectroscopy (LIBS)
    Cremers, DA
    Ebinger, MH
    Breshears, DD
    Unkefer, PJ
    Kammerdiener, SA
    Ferris, MJ
    Catlett, KM
    Brown, JR
    JOURNAL OF ENVIRONMENTAL QUALITY, 2001, 30 (06) : 2202 - 2206
  • [49] Laser-Induced Breakdown Spectroscopy (LIBS) for Trace Element Detection: A Review
    Khan, Z. H.
    Ullah, M. Hedayet
    Rahman, Bulu
    Talukder, Aminul I.
    Wahadoszamen, Md.
    Abedin, K. M.
    Haider, A. F. M. Y.
    JOURNAL OF SPECTROSCOPY, 2022, 2022
  • [50] Laser-Induced Breakdown Spectroscopy (LIBS) on Geological Samples: Compositional Differentiation
    S. N. Panya panya
    A. H. Galmed
    M. Maaza
    B. M. Mothudi
    M. A. Harith
    J. Kennedy
    MRS Advances, 2018, 3 (34-35) : 1969 - 1983