Analysis of Pesticide Residues on Fruit Using Swab Spray Ionization Mass Spectrometry

被引:6
|
作者
Muggli, Thomas Michael [1 ]
Schurch, Stefan [1 ]
机构
[1] Univ Bern, Dept Chem Biochem & Pharmaceut Sci, CH-3012 Bern, Switzerland
来源
MOLECULES | 2023年 / 28卷 / 18期
关键词
pesticide analysis; quantitation; ambient ionization; swab spray ionization; mass spectrometry; METABOLITES;
D O I
10.3390/molecules28186611
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The vast quantity and high variety of pesticides globally used in agriculture entails considerable risks for the environment and requires ensuring the safety of food products. Therefore, powerful analytical tools are needed to acquire qualitative and quantitative data for monitoring pesticide residues. The development of ambient ionization mass spectrometry methods in the past two decades has demonstrated numerous ways to generate ions under atmospheric conditions and simultaneously to reduce the need for extended sample preparation and circumvent chromatographic separation prior to mass analysis. Swab spray ionization enables the generation of ions directly from swabs via the application of high voltage and solvent flow. In this study, swab sampling of fruit surfaces and subsequent ionization directly from the swab in a modified electrospray ion source was employed for the screening and quantitation of pesticide residues. Aspects regarding sample collection, sampling efficacy on different surfaces, and swab background are discussed. The effect of solvent composition on pesticide-sodium adduct formation and the suppression of ionization by the background matrix have been investigated. Furthermore, a novel approach for the quantitation of pesticide residues based on depletion curve areas is presented. It is demonstrated that swab spray ionization is an effective and quick method for spectral library-based identification and the quantitative analysis of polar contact pesticide residues on food.
引用
收藏
页数:14
相关论文
共 50 条
  • [11] Direct coupling of semi-micro liquid chromatography and sonic spray ionization mass spectrometry for pesticide analysis
    Hirabayashi, Y
    Takada, Y
    Hirabayashi, A
    Sakairi, M
    Koizumi, H
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1996, 10 (15) : 1891 - 1893
  • [12] Direct Coupling of Semi-micro Liquid Chromatography and Sonic Spray Ionization Mass Spectrometry for Pesticide Analysis
    Hirabayashi, Y.
    Takada, Y.
    Hirabayashi, A.
    Sakairi, M.
    Rapid Communications in Mass Spectrometry, 10 (15):
  • [13] Direct drug analysis from oral fluid using medical swab touch spray mass spectrometry
    Pirro, Valentina
    Jarmusch, Alan K.
    Vincenti, Marco
    Cooks, R. Graham
    ANALYTICA CHIMICA ACTA, 2015, 861 : 47 - 54
  • [14] Determination of 215 pesticide residues in ginger using liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Cao Jing
    Pang Guofang
    Wang Minglin
    Fan Chunlin
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2010, 28 (06) : 579 - 589
  • [15] Teflon Spray Ionization Mass Spectrometry
    Narayanan, Rahul
    Song, Xiaowei
    Chen, Hao
    Zare, Richard N.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2020, 31 (02) : 234 - 239
  • [16] In situ analysis of agrochemical residues on fruit using ambient ionization on a handheld mass spectrometer
    Soparawalla, Santosh
    Tadjimukhamedov, Fatkhulla K.
    Wiley, Joshua S.
    Ouyang, Zheng
    Cooks, R. Graham
    ANALYST, 2011, 136 (21) : 4392 - 4396
  • [17] Pesticide residues in fruit samples: comparison of different QuEChERS methods using liquid chromatography–tandem mass spectrometry
    C. Christia
    E. Bizani
    C. Christophoridis
    K. Fytianos
    Environmental Science and Pollution Research, 2015, 22 : 13167 - 13178
  • [18] Medical Swab Analysis Using Desorption Electrospray Ionization Mass Spectrometry: A Noninvasive Approach for Mucosal Diagnostics
    Pruski, Pamela
    MacIntyre, David A.
    Lewis, Holly V.
    Inglese, Paolo
    Correia, Goncalo D. S.
    Hansel, Trevor T.
    Bennett, Phillip R.
    Holmes, Elaine
    Takats, Zoltan
    ANALYTICAL CHEMISTRY, 2017, 89 (03) : 1540 - 1550
  • [19] Conductive Polymer Spray Ionization Mass Spectrometry for Biofluid Analysis
    Song, Xiaowei
    Chen, Hao
    Zare, Richard N.
    ANALYTICAL CHEMISTRY, 2018, 90 (21) : 12878 - 12885
  • [20] Direct analysis of herbicides by paper spray ionization mass spectrometry
    Reeber, Steven L.
    Gadi, Sneha
    Huang, Sung-Ben
    Glish, Gary L.
    ANALYTICAL METHODS, 2015, 7 (23) : 9808 - 9816