Effect of Electrode Spacing on the Detection of Coating Defects in Buried Pipelines Using Direct Current Voltage Gradient Method

被引:2
|
作者
Choi, Seung-Heon [1 ]
Yoo, Young-Ran [2 ]
Kim, Young-Sik [1 ,2 ]
机构
[1] Andong Natl Univ, Dept Mat Sci & Engn, 1375 Gyeongdong Ro, Andong 36729, Gyeongbuk, South Korea
[2] Andong Natl Univ, Mat Res Ctr Energy & Clean Technol, 1375 Gyeongdong Ro, Andong 36729, Gyeongbuk, South Korea
关键词
buried pipe; DCVG; real-time coating defect detection system; FEM simulation; electrode spacing; CATHODIC-PROTECTION; CORRODED PIPELINES; FLAW DETECTION; CORROSION; RELIABILITY; PIPES;
D O I
10.3390/coatings13081471
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Buried piping is subject to soil corrosion, which can be prevented by combining coatings and cathodic protection to maximize corrosion control. However, even with both methods, coatings are subject to damage from external factors and various causes. Buried piping may expose the metal and alter the current flow, which in turn causes corrosion. Therefore, this study analyzed the effect of detection electrode spacing on the direct current voltage gradient (DCVG) magnitude formed for coated pipelines buried in the soil. The DCVG was measured using a real-time coating defect detection system. FEM model simulations were carried out, and then the result was compared to the measured DCVG magnitude. When the spacing of the detection electrodes increased, the detected signal and signal location changed. The detection reliability increased as the noise signal is eliminated at the optimum detection electrode spacing. However, the detection reliability decreased at higher selection electrode spacing as the noise signal and detected signals together were eliminated. The location of the detected signal shifted as the spacing of the detection electrodes increased due to the change in the detection reference point and signal magnitude.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] A DC Series Arc Fault Detection Method Using Line Current and Supply Voltage
    Lu, Qiwei
    Ye, Zeyu
    Su, Mengmeng
    Li, Yasong
    Sun, Yuce
    Huang, Hanqing
    IEEE ACCESS, 2020, 8 (08): : 10134 - 10146
  • [22] Forward modeling and inversion of direct current method for the damaged site detection on the anticorrosion coating of Underground metal pipeline
    Meng Xiangjun
    Liu Huaishan
    Zhang Xunhua
    INFORMATION TECHNOLOGY APPLICATIONS IN INDUSTRY II, PTS 1-4, 2013, 411-414 : 1619 - +
  • [23] Detection of Extracochlear Electrodes Using Stimulation-Current- Induced Non-Stimulating Electrode Voltage Recordings With Different Electrode Designs
    de Rijk, Simone R.
    Hammond-Kenny, Amy
    Tam, Yu C.
    Eitutis, Susan T.
    Garcia, Charlotte
    Carlyon, Robert P.
    Bance, Manohar
    OTOLOGY & NEUROTOLOGY, 2022, 43 (05) : E548 - E557
  • [24] Fault location method for high-voltage direct current transmission line using incident current travelling waves
    Wang, Bin
    Yang, Lin
    Dong, Xinzhou
    JOURNAL OF ENGINEERING-JOE, 2018, (15): : 1165 - 1168
  • [25] A method for using Josephson voltage standards for direct characterization of high performance digitizers to establish AC voltage and current traceability to SI
    Ireland, J.
    Reuvekamp, P.G.
    Williams, J.M.
    Peral, D.
    Díaz de Aguilar, J.
    Sanmamed, Y.A.
    Šíra, M.
    Mašláň, S.
    Rzodkiewicz, W.
    Bruszewski, P.
    Sadkowski, G.
    Sosso, A.
    Cabral, V.
    Malmbekk, H.
    Pokatilov, A.
    Herick, J.
    Behr, R.
    Coşkun Öztürk, T.
    Arifoviç, M.
    Ilić, D.
    Measurement Science and Technology, 2022, 34 (01):
  • [26] A method for using Josephson voltage standards for direct characterization of high performance digitizers to establish AC voltage and current traceability to SI
    Ireland, J.
    Reuvekamp, P. G.
    Williams, J. M.
    Peral, D.
    Diaz de Aguilar, J.
    Sanmamed, Y. A.
    Sira, M.
    Maslan, S.
    Rzodkiewicz, W.
    Bruszewski, P.
    Sadkowski, G.
    Sosso, A.
    Cabral, V
    Malmbekk, H.
    Pokatilov, A.
    Herick, J.
    Behr, R.
    Ozturk, T. Coskun
    Arifovic, M.
    Ilic, D.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2023, 34 (01)
  • [27] Specifics of Using Two-Electrode Method of Intensive Measurements for Determining the State of Corrosion-Resistant Coating of Main Pipelines of the Western Siberia
    Pyalchenkov, D. V.
    Tryascin, R. N.
    Gostev, V. V.
    INTERNATIONAL SCIENTIFIC-PRACTICAL CONFERENCE OF STUDENTS, GRADUATE STUDENTS AND YOUNG SCIENTISTS TRANSPORT AND STORAGE OF HYDROCARBONS, 2016, 154
  • [28] Partial Discharge Detection and Induced Surface Current Analysis Using Transient Earth Voltage Method for High Voltage Equipment
    Itose, Akihiko
    Kozako, Masahiro
    Hikita, Masayuki
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 456 - 460
  • [29] An islanding detection method for distributed generations using voltage unbalance and total harmonic distortion of current
    Jang, SI
    Kim, KH
    IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (02) : 745 - 752
  • [30] Evaluation of skin barrier function using direct current I: Effects of conductivity, voltage, distance between electrodes and electrode area
    Kanebako, M
    Inagi, T
    Takayama, K