Subacromial Balloon Spacer Does Not Reduce the Retear Rate for Massive Rotator Cuff Tears: A Comparative Study

被引:5
|
作者
Minarro, Jose Carlos [1 ,2 ]
Bassi, Cristina [1 ]
Boltuch, Andrew [1 ]
Urbano-Luque, Maite [3 ]
Buijze, Geert Alexander [1 ]
Lafosse, Laurent [1 ]
Lafosse, Thibault [1 ]
机构
[1] Alps Surg Inst, Upper Limb Dept, Annecy, France
[2] Hosp Univ Reina Sofia, Cordoba, Spain
[3] Univ Cordoba, Cordoba, Spain
关键词
SUGAYA CLASSIFICATION; REPAIR; INTEGRITY; MULTICENTER; OUTCOMES;
D O I
10.1016/j.arthro.2023.06.032
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To determine whether a subacromial spacer decreases the recurrent rotator cuff tear rate in arthroscopically managed massive rotator cuff tears (MRCTs) with 1 year of follow-up. Methods: We selected all patients who met the following criteria: (1) an MRCT excluding Collin type A, (2) Goutallier stage equal or less than 2, and (3) complete arthroscopic repair of the MRCT. Patients were allocated into 2 groups: A (without subacromial spacer) or B (with subacromial spacer) for a prospective evaluation 1 year after surgery. The primary outcome was the retear rate, determined with magnetic resonance imaging (MRI) according to the classification of Sugaya. Secondary outcome measures were the functional outcomes using visual analog score, Shoulder Subjective Value, and ConstanteMurley Score. Preoperative rotator cuff characteristics such as number of tendons involved and the tear retraction also were evaluated. Patient-related data such as sex, age, laterality, history of smoking, and diabetes mellitus were analyzed. Results: In total, 31 patients were included in group A and 33 in group B. Preoperatively, only 2 differences were found between both groups: a significant (but not clinical) greater Constant score in group A (P = .034) and a slightly greater retraction of the supraspinatus in group B (P = .0025). The overall retear rate between the 2 groups was similar regarding the number of patients (P = .746) and the total number of tendons involved in the recurrent tear (P = .112). At 1-year follow-up, no differences were found in VAS (P = .397), SSV (P = .309), and Constant score (P = .105). Conclusions: In reparable massive rotator cuff tears (excluding Collin type A), the augmentation of repair with a subacromial spacer did not significantly reduce the number of patients with recurrent rotator cuff tears identified by MRI. It was also ineffective in reducing the number of reruptured tendons in these patients. No patient-reported or clinically significant findings were noted in Constant, SSV, and VAS scores at 1-year postoperative follow-up. Patients with MRI findings of a healed rotator cuff (Sugaya 1-3) had better clinical outcomes compared with those without. Level of Evidence: Level III, retrospective comparative study.
引用
收藏
页码:242 / 248
页数:7
相关论文
共 50 条
  • [41] Editorial Commentary: Subacromial Balloon Spacer for Irreparable Rotator Cuff Tears Produces Clinical Improvement, Yet the Mechanism of Action Is Unclear
    Balazs, George C.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2024, 40 (02): : 551 - 552
  • [42] Outcomes of superior capsule reconstruction for massive rotator cuff tears and risk factors for postoperative retear
    Satoru Ohta
    Osamu Komai
    Yuuki Onochi
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 1319 - 1325
  • [43] Latissimus Dorsi Transfer Combined with Subacromial Balloon Spacer for Bidirectional Rotator Cuff Deficiency
    Velasquez Garcia, Ausberto
    Osorio Valdivia, Pedro
    Brito, Cristian
    Mendez, Magdalena
    ARTHROSCOPY TECHNIQUES, 2022, 11 (12): : E2327 - E2335
  • [44] Arthroscopic Subacromial Spacer Implantation in Patients With Massive Irreparable Rotator Cuff Tears: Clinical and Radiographic Results of 39 Retrospectives Cases
    Deranlot, Julien
    Herisson, Olivier
    Nourissat, Geoffroy
    Zbili, David
    Werthel, Jean David
    Vigan, Marie
    Bruchou, Francois
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2017, 33 (09): : 1639 - 1644
  • [45] Repair of Massive Rotator Cuff Tear With Medialization and Balloon Spacer Insertion
    Ho, Sean Wei Loong
    ARTHROSCOPY TECHNIQUES, 2024, 13 (01):
  • [46] Outcomes of superior capsule reconstruction for massive rotator cuff tears and risk factors for postoperative retear
    Ohta, Satoru
    Komai, Osamu
    Onochi, Yuuki
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (10) : 1319 - 1325
  • [47] Editorial Commentary: Subacromial Balloon Spacer for Management of Massive Irreparable Posterosuperior Rotator Cuff Tears Improves Shoulder Range of Motion and Patient-Reported Outcome Measures
    Cotter, Eric J.
    Verma, Nikhil N.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2024, 40 (01): : 174 - 175
  • [48] Augmented Fixation With Biodegradable Subacromial Spacer After Repair of Massive Rotator Cuff Tear
    Bozkurt, Murat
    Akkaya, Mustafa
    Gursoy, Safa
    Isik, Cetin
    ARTHROSCOPY TECHNIQUES, 2015, 4 (05): : E471 - E474
  • [49] In Symptomatic Irreparable Rotator Cuff Tears, Adding a Subacromial Balloon Spacer to Debridement Resulted in Worse Shoulder Pain and Function at 12 Months
    Frankle, Mark A.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2022, 104 (22): : 2037 - 2037
  • [50] The use of a subacromial spacer-inspace balloon in managing patients with irreparable rotator cuff tears (vol 15, pg 862, 2018)
    Yallapragada, Rahi Kiran
    Apostolopoulos, Alex
    Katsougrakis, I.
    Selvan, T. P.
    JOURNAL OF ORTHOPAEDICS, 2021, 23 : 275 - 275