摘要
Purpose: To determine whether a subacromial spacer decreases the recurrent rotator cuff tear rate in arthroscopically managed massive rotator cuff tears (MRCTs) with 1 year of follow-up. Methods: We selected all patients who met the following criteria: (1) an MRCT excluding Collin type A, (2) Goutallier stage equal or less than 2, and (3) complete arthroscopic repair of the MRCT. Patients were allocated into 2 groups: A (without subacromial spacer) or B (with subacromial spacer) for a prospective evaluation 1 year after surgery. The primary outcome was the retear rate, determined with magnetic resonance imaging (MRI) according to the classification of Sugaya. Secondary outcome measures were the functional outcomes using visual analog score, Shoulder Subjective Value, and ConstanteMurley Score. Preoperative rotator cuff characteristics such as number of tendons involved and the tear retraction also were evaluated. Patient-related data such as sex, age, laterality, history of smoking, and diabetes mellitus were analyzed. Results: In total, 31 patients were included in group A and 33 in group B. Preoperatively, only 2 differences were found between both groups: a significant (but not clinical) greater Constant score in group A (P = .034) and a slightly greater retraction of the supraspinatus in group B (P = .0025). The overall retear rate between the 2 groups was similar regarding the number of patients (P = .746) and the total number of tendons involved in the recurrent tear (P = .112). At 1-year follow-up, no differences were found in VAS (P = .397), SSV (P = .309), and Constant score (P = .105). Conclusions: In reparable massive rotator cuff tears (excluding Collin type A), the augmentation of repair with a subacromial spacer did not significantly reduce the number of patients with recurrent rotator cuff tears identified by MRI. It was also ineffective in reducing the number of reruptured tendons in these patients. No patient-reported or clinically significant findings were noted in Constant, SSV, and VAS scores at 1-year postoperative follow-up. Patients with MRI findings of a healed rotator cuff (Sugaya 1-3) had better clinical outcomes compared with those without. Level of Evidence: Level III, retrospective comparative study.
引用
收藏
页码:242 / 248
页数:7
相关论文
共 50 条
  • [1] Subacromial Balloon Spacer for Massive Irreparable Rotator Cuff Tears
    Srikumaran, Uma
    Russo, Raffaella
    Familiari, Filippo
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2023, 39 (03): : 576 - 577
  • [2] Subacromial balloon spacer for irreparable rotator cuff tears
    Beard, David
    Chokotho, Linda
    LANCET, 2022, 399 (10339): : 1920 - 1921
  • [3] Outcomes of Subacromial Balloon Spacer Implantation for Massive and Irreparable Rotator Cuff Tears: A Systematic Review
    Stewart, Russell K.
    Kaplin, Lisa
    Parada, Stephen A.
    Graves, Benjamin R.
    Verma, Nikhil N.
    Waterman, Brian R.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2019, 7 (10)
  • [4] Comparative cost-effectiveness analysis of the subacromial spacer for irreparable and massive rotator cuff tears
    Castagna, Alessandro
    Garofalo, Raffaele
    Maman, Eran
    Gray, Alisha C.
    Brooks, Elizabeth A.
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (02) : 395 - 403
  • [5] Comparative cost-effectiveness analysis of the subacromial spacer for irreparable and massive rotator cuff tears
    Alessandro Castagna
    Raffaele Garofalo
    Eran Maman
    Alisha C. Gray
    Elizabeth A. Brooks
    International Orthopaedics, 2019, 43 : 395 - 403
  • [6] Subacromial Spacer for Irreparable Rotator Cuff Tears
    Riff, Andrew J.
    Verma, Nikhil N.
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2018, 26 (01) : 44 - 47
  • [7] Irreparable Massive Rotator Cuff Tears: Subacromial Balloon Surgical Technique
    Rondon, Alexander J.
    Farronato, Dominic M.
    Pezzulo, Joshua D.
    Abboud, Joseph A.
    ARTHROSCOPY TECHNIQUES, 2023, 12 (03): : E421 - E432
  • [8] Biomechanics of Biodegradable Subacromial Balloon Spacer for Irreparable Superior Rotator Cuff Tears
    Lobao, Mario H.
    Canham, R. Bruce
    Melvani, Roshan T.
    Abboud, Joseph A.
    Parks, Brent G.
    Murthi, Anand M.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (11):
  • [9] New Solution for Massive, Irreparable Rotator Cuff Tears: The Subacromial "Biodegradable Spacer"
    Savarese, Eugenio
    Romeo, Rocco
    ARTHROSCOPY TECHNIQUES, 2012, 1 (01): : E69 - E74
  • [10] Subacromial Balloon Spacer Implantation Is a Promising Alternative for Patients With Massive Irreparable Rotator Cuff Tears: A Systematic Review
    Levy, Kenneth H.
    White, Christopher A.
    Pujari, Amit
    Patel, Akshar, V
    Kator, Jamie L.
    Parsons, Bradford O.
    Galatz, Leesa M.
    Cagle, Paul J.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2024, 40 (01): : 162 - 173.e2