Performance of Computed Tomographic Angiography-Based Aortic Valve Area for Assessment of Aortic Stenosis

被引:4
|
作者
Ash, Jerry [1 ]
Sandhu, Gurmandeep S. [1 ,2 ]
Arriola-Montenegro, Jose [2 ]
Agakishiev, Dzhalal [2 ]
Clavel, Marie-Annick [3 ]
Pibarot, Philippe [3 ]
Duval, Sue [1 ]
Nijjar, Prabhjot S. [1 ,4 ]
机构
[1] Univ Minnesota, Med Sch, Dept Med, Cardiovasc Div, Minneapolis, MN USA
[2] Univ Minnesota, Med Sch, Dept Med, Minneapolis, MN USA
[3] Laval Univ, Quebec Heart & Lung Inst, Inst Univ Cardiol & Pneumol Quebec, Quebec City, PQ, Canada
[4] Univ Minnesota, Med Ctr, 420 Delaware St SE,MMC 508, Minneapolis, MN 55455 USA
来源
关键词
aortic stenosis; computed tomography; echocardiography;
D O I
10.1161/JAHA.123.029973
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundA total of 40% of patients with severe aortic stenosis (AS) have low-gradient AS, raising uncertainty about AS severity. Aortic valve calcification, measured by computed tomography (CT), is guideline-endorsed to aid in such cases. The performance of different CT-derived aortic valve areas (AVAs) is less well studied. Methods and ResultsConsecutive adult patients with presumed moderate and severe AS based on echocardiography (AVA measured by continuity equation on echocardiography <1.5 cm(2)) who underwent cardiac CT were identified retrospectively. AVAs, measured by direct planimetry on CT (AVA(CT)) and by a hybrid approach (AVA measured in a hybrid manner with echocardiography and CT [AVA(Hybrid)]), were measured. Sex-specific aortic valve calcification thresholds (& GE;1200 Agatston units in women and & GE;2000 Agatston units in men) were applied to adjudicate severe or nonsevere AS. A total of 215 patients (38.0% women; mean & PLUSMN;SD age, 78 & PLUSMN;8 years) were included: normal flow, 59.5%; and low flow, 40.5%. Among the different thresholds for AVA(CT) and AVA(Hybrid), diagnostic performance was the best for AVA(CT) <1.2 cm(2) (sensitivity, 85%; specificity, 26%; and accuracy, 72%), with no significant difference by flow status. The percentage of patients with correctly classified AS severity (correctly classified severe AS+correctly classified moderate AS) was as follows; AVA measured by continuity equation on echocardiography <1.0 cm(2), 77%; AVA(CT) <1.2 cm(2), 73%; AVA(CT) <1.0 cm(2), 58%; AVA(Hybrid) <1.2 cm(2), 59%; and AVA(Hybrid) <1.0 cm(2), 45%. AVA(CT) cut points of 1.52 cm(2) for normal flow and 1.56 cm(2) for low flow, provided 95% specificity for excluding severe AS. ConclusionsCT-derived AVAs have poor discrimination for AS severity. Using an AVA(CT) <1.2-cm(2) threshold to define severe AS can produce significant error. Larger AVA(CT) thresholds improve specificity.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] REPLY: Comparison of Echocardiography and CT for the Assessment of Aortic Stenosis Valve Area
    Clavel, Marie-Annick
    Malouf, Joseph
    Messika-Zeitoun, David
    Araoz, Phillip A.
    Michelena, Hector I.
    Enriquez-Sarano, Maurice
    JACC-CARDIOVASCULAR IMAGING, 2015, 8 (09) : 1116 - 1116
  • [42] Incremental prognostic value of cardiac computed tomography angiography in asymptomatic aortic stenosis: Significance of aortic valve calcium score
    Utsunomiya, Hiroto
    Yamamoto, Hideya
    Kitagawa, Toshiro
    Kunita, Eiji
    Urabe, Yoji
    Tsushima, Hiroshi
    Hidaka, Takayuki
    Awai, Kazuo
    Kihara, Yasuki
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (06) : 5205 - 5211
  • [43] The Buddy Balloon for Transcatheter Aortic Valve Replacement: Insights From Computed Tomographic Assessment of the Aortic Valvular Complex
    Okuyama, Kazuaki
    Jilaihawi, Hasan
    Makkar, Raj R.
    JOURNAL OF INVASIVE CARDIOLOGY, 2013, 25 (09): : 468 - 470
  • [44] SEX-SPECIFIC DIFFERENCES IN AORTIC VALVE COMPOSITION QUANTIFIED FROM COMPUTED TOMOGRAPHY ANGIOGRAPHY IN SEVERE AORTIC STENOSIS
    Grodecki, Kajetan
    Huczek, Zenon
    Lin, Andrew
    Protasiewicz, Marcin
    Walczak, Andrzej
    Dariusz, Jagielak
    Grygier, Marek
    Kochman, Janusz
    Wojakowski, Wojciech
    Dey, Damini
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 1240 - 1240
  • [45] ASSESSMENT OF THE SEVERITY OF AORTIC-STENOSIS - COMPARISON OF GRADIENT AND VALVE AREA
    ENDRYS, J
    YOUSOF, AM
    STRANSKY, P
    PEDIATRIC CARDIOLOGY, 1986, 6 (05) : 263 - 267
  • [46] Assessment of Aortic Pathology and Peripheral Arterial Disease Using Multidetector Computed Tomographic Angiography
    Lin, Peter H.
    Bechara, Carlos
    Kougias, Panagiotis
    Huynh, Tam T.
    LeMaire, Scott A.
    Coselli, Joseph S.
    VASCULAR AND ENDOVASCULAR SURGERY, 2008, 42 (06) : 583 - 598
  • [47] Aortic valve area on 64-slice computed tomography strongly correlates with transesophageal echocardiography in aortic stenosis
    LaBounty, Troy
    Sundaram, Baskaran
    Agarwal, Prachi
    Armstrong, William
    Kazerooni, Ella A.
    Yamada, Elma
    CIRCULATION, 2007, 116 (16) : 611 - 611
  • [48] Clinical application of aortic valve calcification score for assessment of aortic valve stenosis
    Kim, Y. N.
    Song, J. K.
    Lim, S. Y.
    Choi, H. N.
    Heo, R.
    Kim, D. H.
    Song, J. M.
    Kang, D. H.
    EUROPEAN HEART JOURNAL, 2016, 37 : 1353 - 1353
  • [49] Valve area and the risk of overestimating aortic stenosis
    Gonzalez-Mansilla, Ana
    Martinez-Legazpi, Pablo
    Prieto, Andrea
    Goma, Elena
    Haurigot, Pilar
    Perez del Villar, Candelas
    Cuadrado, Victor
    Delgado-Montero, Antonia
    Prieto, Raquel
    Mombiela, Teresa
    Perez-David, Esther
    Rodriguez Gonzalez, Elena
    Benito, Yolanda
    Yotti, Raquel
    Perez-Vallina, Manuel
    Fernandez-Aviles, Francisco
    Bermejo, Javier
    HEART, 2019, 105 (12) : 911 - +
  • [50] A computed tomography angiography-based radiomics model for prognostic prediction of endovascular abdominal aortic repair
    Huang, Shanya
    Liu, Dingxiao
    Deng, Kai
    Shu, Chang
    Wu, Yan
    Zhou, Zhiguang
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2025, 429