Heartbeat detection from single-lead ECG contaminated with simulated EMG at different intensity levels: A comparative study

被引:7
|
作者
Beni, Nargess Heydari [1 ]
Jiang, Ning [2 ]
机构
[1] Univ Waterloo, Dept Syst Design Engn, Waterloo, ON, Canada
[2] West China Hosp Sichuan Univ, Sichuan Univ, Natl Clin Res Ctr Geriatr, China & Medx Ctr Mfg, Chengdu, Sichuan, Peoples R China
关键词
Heartbeat detection; EMG; ECG; SWT; CEEMDAN; SNR; EMPIRICAL-MODE DECOMPOSITION; FEATURE-EXTRACTION;
D O I
10.1016/j.bspc.2023.104612
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Electrocardiogram (ECG) signals quality can be seriously affected by artifacts such as electromyogram (EMG), negatively impacting its clinical value. Various denoising methods have been proposed to address this issue in the literature. We examined how simulated EMG artifacts affect the heartbeat detection performance of different ECG denoising pipelines at four EMG intensity levels (N1,...,N4), by adding simulated EMG to ECG signals from two different datasets: MIT-BIH arrhythmia dataset (dataset 1) and data we collected from 20 healthy partici-pants (dataset 2). Five different pipelines were investigated: CEEMDAN (Cd), CEEMDAN-ICA (Cd-I), SWT(WT), CEEMDAN-SWT (Cd-W), and CEEMDAN-ICA-SWT (Cd-I-W). For dataset 1, Cd and WT provided the best heart-beat detection performance at noise levels N1-N2 and N3-N4, respectively. For dataset 2, WT and Cd_I performed best at N1, while WT performed best at N2-N4. We further investigated the robustness of the pipelines against varying EMG intensity. We observed that the pipelines involving SWT (WT, Cd-W, Cd-I-W) considerably out-performed others in robustness against noise. Cd-I-W and WT were the most robust pipelines for dataset 1 and 2, respectively. As such, the potential artifact level in the environment of ECG should be assessed for selecting an appropriate denoising method.
引用
收藏
页数:12
相关论文
共 39 条
  • [31] Automatic detection of sleep apnea from single-lead ECG signal using enhanced-deep belief network model
    Tyagi, Praveen Kumar
    Agrawal, Dheeraj
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 80
  • [32] Multiscale Deep Neural Network for Obstructive Sleep Apnea Detection Using RR Interval From Single-Lead ECG Signal
    Shen, Qi
    Qin, Hengji
    Wei, Keming
    Liu, Guanzheng
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [33] Automatic Detection of Obstructive Sleep Apnea Using Wavelet Transform and Entropy-Based Features From Single-Lead ECG Signal
    Zarei, Asghar
    Asl, Babak Mohammadzadeh
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2019, 23 (03) : 1011 - 1021
  • [34] PRIMARY CARE PHYSICIAN EXPERIENCE WITH SINGLE-LEAD ECG SCREENING FOR UNDIAGNOSED AF: RESULTS FROM THE VITAL-AF STUDY
    Ashburner, Jeffrey M.
    Lin, Aimee K.
    Rivet, ColinM.
    Lee, Priscilla R.
    Leonard, Courtney E.
    Bussineau, Margaret
    Lipsanopoulos, Ana T. Trisini
    Borowsky, Leila H.
    Guan, Wyliena
    Li, Xinye
    Chang, Yuchiao
    Khurshid, Shaan
    Ellinor, Patrick T.
    Singer, Daniel E.
    McManus, David D.
    Lubitz, Steven A.
    Atlas, Steven J.
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2020, 35 (SUPPL 1) : S238 - S239
  • [35] Detection of Fetal ECG R Wave From Single-Lead Abdominal ECG Using a Combination of RR Time-Series Smoothing and Template-Matching Approach
    Liu, He
    Chen, Deyun
    Sun, Guanghao
    IEEE ACCESS, 2019, 7 : 66633 - 66643
  • [36] Sleep apnea detection from a single-lead ECG signal with automatic feature-extraction through a modified LeNet-5 convolutional neural network
    Wang, Tao
    Lu, Changhua
    Shen, Guohao
    Hong, Feng
    PEERJ, 2019, 7
  • [37] Arrhythmia detection based on multi-scale fusion of hybrid deep models from single lead ECG recordings: A multicenter dataset study
    Ma, Chenbin
    Lan, Ke
    Wang, Jing
    Yang, Zhicheng
    Zhang, Zhengbo
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 77
  • [38] A comparative study of manganese and lead levels in human umbilical cords and maternal blood from two urban centers exposed to different gasoline additives
    Audrey, S
    Takser, L
    André, M
    Martin, S
    Donna, M
    Geneviève, SA
    Philippe, B
    Georgette, H
    Guy, H
    SCIENCE OF THE TOTAL ENVIRONMENT, 2002, 290 (1-3) : 157 - 164
  • [39] A comparative study of manganese and lead levels in human umbilical cords and maternal blood from two urban centers exposed to different gasoline additives (vol 290, pg 157, 2002)
    Smargiassi, AE
    Takser, L
    Masse, A
    Sergerie, M
    Mergler, D
    St-Amour, G
    Blot, P
    Hellier, G
    Huel, G
    SCIENCE OF THE TOTAL ENVIRONMENT, 2002, 300 (1-3) : 247 - 247