Transient flow analysis on opening process of pneumatic gas proportional valve with two-solenoid valve

被引:7
|
作者
Liu, Fengguo [1 ,2 ]
Cao, Shihua [1 ]
Zhou, Wenlei [1 ]
Zhao, Dongfang [1 ]
Zheng, Longfeng [1 ]
Shao, Meng [1 ]
机构
[1] Tianjin Chengjian Univ, Sch Energy & Safety Engn, Tianjin 300384, Peoples R China
[2] Tianjin Engn Ctr Nat Gas High Efficiency Utilizat, Tianjin 300384, Peoples R China
关键词
Gas proportional valve; Spool opening; Flow; Outlet flow rate; CFD; CFD ANALYSIS; SIMULATION; DYNAMICS; FORCES; SPOOL; MODEL;
D O I
10.1016/j.flowmeasinst.2022.102291
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The gas proportional valve (GPV) is a pneumatic pressure regulator, and the change in operating pressure will directly affect the opening and closing condition of the spool. In this study, the procedure for opening the spool is studied. The process of regulating the pressure of the GPV is revealed by the dynamical simulation method. The characteristics of displacement, total pressure and velocity of the spool during opening are analyzed. As time increases, it is found that the turbulence in the downstream of GPV becomes more obvious. In the process of spool movement, the influence of different inlet working pressures on spool displacement is analyzed. With a full open time of less than 1.5 x 10(boolean AND) (-2) s, the spool reaches the stable state of full opening. In addition, the transient process of outlet flow is also studied. The simulated outlet flow is stable at 152 m(3)/h for the maximum opening. In order to verify the simulation results, the test of valve flow is carried out on the test bench. The results show that these methods can reduce the design difficulty and provide a reference for further optimization and engineering application of GPV.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] ANALYSIS OF THE TRANSIENT ELECTROMAGNETIC FIELD OF DIRECT ACTION SOLENOID VALVE
    Liu, Qianfeng
    Bo, Hanliang
    Qin, Benke
    PROCEEDINGS OF THE 20TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING AND THE ASME 2012 POWER CONFERENCE - 2012, VOL 1, 2012, : 475 - 479
  • [22] Transient flow characteristic of cut-off valve in opening-closing process
    Song, Zhi-Wei
    Cui, Bao-Ling
    Shang, Zhao-Hui
    Lin, Zhe
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2012, 33 (06): : 957 - 960
  • [23] The simulation analysis for cartridge proportional flow valve
    Dong, Peng
    Zhao, Shengdun
    Dong, Yuanzhe
    Fan, Shuqin
    2016 3RD INTERNATIONAL CONFERENCE ON MECHANICS AND MECHATRONICS RESEARCH (ICMMR 2016), 2016, 77
  • [24] Dynamic analysis of a pilot-operated two-stage solenoid valve used in pneumatic system
    Ye Qifang
    Chen Jiangping
    SIMULATION MODELLING PRACTICE AND THEORY, 2009, 17 (05) : 794 - 816
  • [25] Study on measuring flow rate characteristic of pneumatic solenoid valve by isothermal chamber discharge
    Liu, CL
    Yang, LH
    Ye, Q
    Proceedings of the Sixth International Conference on Fluid Power Transmission and Control, 2005, : 877 - 881
  • [26] Research on Pre- and Post-Processor for Analysis of Proportional Solenoid Valve
    Yun, Dongwon
    Ham, Sangyong
    Park, Jungho
    Yun, Sonam
    Kim, Chilsung
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS A, 2012, 36 (08) : 865 - 871
  • [27] Research on a pneumatic proportional pressure control valve using the CFD analysis
    Renn, J.-C.
    Lin, T.-I.
    Journal of the Chinese Society of Mechanical Engineers, Transactions of the Chinese Institute of Engineers, Series C/Chung-Kuo Chi Hsueh Kung Ch'eng Hsuebo Pao, 2001, 22 (05): : 443 - 450
  • [28] Design and characteristics analysis of a high precision pneumatic proportional pressure valve
    State Key Laboratory of Fluid Power Transmission and Control, Zhejiang University, Hangzhou 310027, China
    不详
    Nongye Jixie Xuebao, 2009, 10 (181-187):
  • [29] A GAS CONTROL VALVE FOR FLOW PROPORTIONAL COUNTERS WITH FACILITIES FOR FLUSHING
    HOLTON, P
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1952, 29 (09): : 300 - 300
  • [30] Research on the relationship between drive current pulsating quantity of proportional solenoid valve and flow hysteresis
    Cai Sheng-nian
    Zhou Ying
    Pang Bao-lin
    Xu Cheng-tao
    Qin Ran
    PROCEEDINGS OF THE 2012 SECOND INTERNATIONAL CONFERENCE ON INSTRUMENTATION & MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC 2012), 2012, : 594 - 597