FDG PET/CT and Endoscopic Ultrasound for Preoperative T-Staging of Esophageal Squamous Cell Carcinoma

被引:0
|
作者
Huang, Yung-Cheng [1 ]
Chiu, Nan-Tsing [2 ]
Lu, Hung-, I [3 ]
Chiu, Yi-Chun [4 ]
Hsu, Chien-Chin [1 ]
Wang, Yu-Ming [5 ]
Li, Shau-Hsuan [6 ]
机构
[1] Chang Gung Univ, Coll Med, Dept Nucl Med, Kaohsiung Chang Gung Mem Hosp, Kaohsiung 83301, Taiwan
[2] Natl Cheng Kung Univ, Coll Med, Natl Cheng Kung Univ Hosp, Dept Nucl Med, Tainan 704, Taiwan
[3] Chang Gung Univ, Kaohsiung Chang Gung Mem Hosp, Coll Med, Dept Thorac & Cardiovasc Surg, Kaohsiung 83301, Taiwan
[4] Chang Gung Univ, Kaohsiung Chang Gung Mem Hosp, Dept Hepatogastroenterol, Coll Med, Kaohsiung 83301, Taiwan
[5] Chang Gung Univ, Kaohsiung Chang Gung Mem Hosp, Dept Radiat Oncol, Coll Med, Kaohsiung 83301, Taiwan
[6] Chang Gung Univ, Coll Med, Kaohsiung Chang Gung Mem Hosp, Dept Hematol Oncol, Kaohsiung 83301, Taiwan
关键词
esophageal squamous cell carcinoma; PET/CT; endoscopic ultrasound; staging; POSITRON-EMISSION-TOMOGRAPHY; STANDARDIZED UPTAKE VALUE; NEOADJUVANT CHEMOTHERAPY; COMPUTED-TOMOGRAPHY; TREATMENT OUTCOMES; CANCER; CHEMORADIOTHERAPY; SURGERY; TUMOR; CHEMORADIATION;
D O I
10.3390/diagnostics13193083
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study aimed to compare the diagnostic performances of endoscopic ultrasound (EUS) and FDG PET/CT in the preoperative T-staging of esophageal squamous cell carcinoma (ESCC) and determine whether their innovative coordination achieves better prediction. In total, 100 patients diagnosed with ESCC, 57 without (CRT[-]sub) and 43 with (CRT[+]sub) neoadjuvant chemoradiotherapy, undergoing EUS and FDG PET/CT, followed by surgical resection of the tumor, were included in this analysis. EUS classified T-stages based on the depth of primary tumor invasion, and FDG PET/CT used thresholded maximal standardized uptake value (SUVmax) classifications. By employing pathology results as the reference standard, we assessed the accuracy of EUS and FDG PET/CT, evaluated their concordance using the kappa statistic, and conducted a comparative analysis between the two modalities through McNemar's chi-square test. FDG PET/CT had higher overall accuracy than EUS (for CRT[-]sub: 71.9%, kappa = 0.56 vs. 56.1%, kappa = 0.31, p = 0.06; for CRT[+]sub: 65.1%, kappa = 0.50 vs. 18.6%, kappa = 0.05, p < 0.01) in predicting pT- and ypT-stage. Our proposed method of incorporating both FDG PET/CT and EUS information could achieve higher accuracies in differentiating between early and locally advanced disease in the CRT[-]sub group (82.5%) and determining residual viable tumor in the CRT[+]sub group (83.7%) than FDG PET/CT or EUS alone. FDG PET/CT had a better diagnostic ability than EUS to predict the (y)pT-stage of ESCC. Our complementary method, which combines the advantages of both imaging modalities, can deliver higher accuracy for clinical applications of ESCC.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Endoscopic ultrasonography in the preoperative staging of esophageal carcinoma.
    Giacoia, A
    Thomas, P
    Giovannini, M
    Hannoun-Levy, JM
    Garbe, L
    Thirion, X
    Lecuyer, J
    Giudicelli, R
    Seitz, JF
    Fuentes, P
    [J]. ANNALES DE CHIRURGIE, 1997, 51 (10): : 1077 - 1083
  • [42] INFLUENCE OF TUMOR STENOSIS ON THE ACCURACY OF ENDOSONOGRAPHY IN PREOPERATIVE T-STAGING OF ESOPHAGEAL CANCER
    HORDIJK, ML
    ZANDER, H
    VANBLANKENSTEIN, M
    TILANUS, HW
    [J]. ENDOSCOPY, 1993, 25 (02) : 171 - 175
  • [43] T-staging of ampullary tumor by endoscopic ultrasound before endoscopic ampullectomy: How reliable is it?
    Nguyen, Nam Q.
    Binmoeller, Kenneth F.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2008, 67 (05) : AB210 - AB210
  • [44] T-staging of ampullary tumor by endoscopic ultrasound before endoscopic ampullectomy: how reliable is it?
    Nguyen, N. Q.
    Binmoeller, K. F.
    [J]. JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2008, 23 : A229 - A229
  • [45] Accuracy of endoscopic ultrasound over time in T-Staging of esophageal cancers: A meta-analysis and systematic review
    Puli, Srinivas R.
    Reddy, Jyotsna Batapati Krishna
    Bechtold, Matthew L.
    Antillon, Mainor R.
    Ibdah, Jamal A.
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2007, 102 : S133 - S133
  • [46] Staging accuracy of endoscopic ultrasound performed by nonexpert endosonographers in patients with resectable esophageal squamous cell carcinoma: is it possible?
    Lee, W. C.
    Lee, T. H.
    Jang, J. Y.
    Lee, J. -S.
    Cho, J. Y.
    Lee, J. S.
    Jeon, S. R.
    Kim, H. G.
    Kim, J. -O.
    Cho, Y. K.
    [J]. DISEASES OF THE ESOPHAGUS, 2015, 28 (06) : 574 - 578
  • [47] Is 18F-FDG PET and PET/CT imaging used appropriately for staging of esophageal carcinoma?
    Dam, Hung
    Grady, Erin
    Bais, Tina
    Decena-Shepherd, Leilani
    Manzone, Timothy
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [48] Is less more in 18F-FDG PET/CT staging of squamous cell carcinoma of the head and neck?
    Pinho, Daniella
    Bulman, Julie
    Wachsmann, Jason
    Moore, William
    Peng, Fangyu
    Oz, Orhan
    Mathews, Dana
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [49] Role of FDG-PET/CT in staging and follow-up of head and neck squamous cell carcinoma
    Mak, D.
    Corry, J.
    Lau, E.
    Rischin, D.
    Hicks, R. J.
    [J]. QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 55 (05): : 487 - 499
  • [50] Impact of FDG-PET/CT imaging on nodal staging for head-and-neck squamous cell carcinoma
    Murakami, Ryuji
    Uozumi, Hideaki
    Hirai, Toshinori
    Nishimura, Ryuichi
    Tomiguchi, Seiji
    Oya, Natsuo
    Katsuragawa, Shigehiko
    Yamashita, Yasuyuki
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (02): : 377 - 382