Study of different types of copper electrodes for anodic stripping voltammetric detection of trace metal ions

被引:7
|
作者
Obrez, Domen [1 ,2 ]
Kolar, Mitja [2 ]
Tasic, Nikola [1 ]
Hocevar, Samo B. [1 ]
机构
[1] Natl Inst Chem, Dept Analyt Chem, Hajdrihova 19, Ljubljana, Slovenia
[2] Univ Ljubljana, Fac Chem & Chem Technol, Vecna Pot 113, Ljubljana, Slovenia
关键词
Copper film electrode; Copper bulk electrode; Copper wire electrode; Lead and cadmium; Anodic stripping voltammetry; FILM ELECTRODES; MERCURY; SILVER;
D O I
10.1016/j.electacta.2023.142480
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Copper electrodes exhibit interesting characteristics for application in electrochemical stripping analysis and represent another alternative to their mercury counterparts. In this work, we studied different types of copperbased electrodes for anodic stripping voltammetric detection of trace metal ions. We investigated copper film (CuFE), and bulk copper electrodes, such as in-situ and ex-situ prepared CuFEs using glassy carbon and screenprinted carbon supporting electrodes, a bulk copper disk and screen-printed copper electrode, and a copper wire as the simplest, inexpensive, and readily available analog. For studying their electroanalytical performances, low concentrations (mu g L-1) of Cd(II) and Pb(II) were used as model ions. We examined and optimized several key parameters affecting the preparation and functioning of copper electrodes, such as the composition of the measurement solution, copper concentration for in-situ and ex-situ preparation of CuFE, deposition potential, deposition time, etc. Most of the tested copper electrodes showed favorable stripping voltammetric performances, particularly the CuFE ex-situ prepared on a glassy carbon electrode and the CuFE in-situ prepared on a screen-printed carbon substrate. Notably, a copper wire revealed an excellent electroanalytical operation with a limit of detection of 0.6 mu g L-1 for Pb(II) and 1.8 mu g L-1 for Cd(II). The practical applicability of a copper electrode was tested by measuring a real tap water sample.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] 3D-printed Metal Electrodes for Heavy Metals Detection by Anodic Stripping Voltammetry
    Lee, Ke Yau
    Ambrosi, Adriano
    Pumera, Martin
    ELECTROANALYSIS, 2017, 29 (11) : 2444 - 2453
  • [42] In-situ prepared copper film electrode for adsorptive stripping voltammetric detection of trace Ni(II)
    Hrastnik, Nana I.
    Jovanovski, Vasko
    Hocevar, Samo B.
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 307 (307):
  • [43] Catalytic adsorptive stripping voltammetric measurements of trace vanadium at bismuth film electrodes
    Wang, Joseph
    Lu, Donglai
    Thongngamdee, Sompong
    Lin, Yuehe
    Sadik, Omowunmi A.
    TALANTA, 2006, 69 (04) : 914 - 917
  • [44] Tellurium Film Electrodes Deposited on Carbon and Mesoporous Carbon Screen-printed Substrates for Anodic Stripping Voltammetric Determination of Copper
    Bobrowski, Andrzej
    Krolicka, Agnieszka
    Sliwa, Julia
    Zarebski, Jerzy
    Economou, Anastasios
    Kalcher, Kurt
    ELECTROANALYSIS, 2018, 30 (09) : 2004 - 2010
  • [45] Differential pulse anodic stripping voltammetric determination of copper(II) with N-phenylcinnamohydroxamic acid modified carbon paste electrodes
    Alemu, H
    Chandravanshi, BS
    ANALYTICA CHIMICA ACTA, 1998, 368 (1-2) : 165 - 173
  • [46] Simultaneous stripping voltammetric determination of zinc, cadmium, thallium and copper ions in different buffer medium as electrolyte
    Yarmohammadi, Mohammad
    Zolata, Hamid Reza
    Aboudzadeh, Mohammad Reza
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2014, 91 (07) : 1283 - 1287
  • [48] A Comparison between Different Machine Learning Approaches Combined with Anodic Stripping Voltammetry for Copper Ions and pH Detection in Cell Culture Media
    Biscaglia, Francesco
    Caroppo, Andrea
    Prontera, Carmela Tania
    Sciurti, Elisa
    Signore, Maria Assunta
    Kuznetsova, Iren
    Leone, Alessandro
    Siciliano, Pietro
    Francioso, Luca
    CHEMOSENSORS, 2023, 11 (01)
  • [49] Introduce of Minoxidil as a Very Selective ligand for Ultra Trace Detection of Copper Ion by Adsorptive Stripping Voltammetric Method
    Ahmadi, Farhad
    Gholivand, Mohammad Bagher
    Yawari, Eilnaz
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2012, 4 (04): : 431 - 446
  • [50] Selenium-coated carbon electrode for anodic stripping voltammetric determination of copper(II)
    Nagaosa, Yukio
    Zong, Ping
    Kamio, Akihiro
    MICROCHIMICA ACTA, 2009, 167 (3-4) : 241 - 246