Biomechanical comparison of different screw-included angles in crossing screw fixation for transverse patellar fracture in level walking: a quasi-dynamic finite element study

被引:6
|
作者
Chang, Chih-Wei [1 ,2 ]
Chen, Yen-Nien [3 ]
Chang, Hung-Chih [4 ]
Li, Chun-Ting [5 ]
机构
[1] Natl Cheng Kung Univ, Coll Med, Dept Orthoped, Tainan, Taiwan
[2] Natl Cheng Kung Univ, Natl Cheng Kung Univ Hosp, Coll Med, Dept Orthoped, Tainan, Taiwan
[3] Asia Univ, Dept Phys Therapy, 500 Lioufeng Rd, Taichung 413305, Taiwan
[4] Hungkuang Univ, Dept Biomed Engn, Taichung, Taiwan
[5] MacKay Med Coll, Inst Geriatr Welf Technol & Sci, 46,Sec 3,Zhongzheng Rd, New Taipei 25245, Taiwan
关键词
Patellar fracture; Crossing screw fixation; Parallel screw fixation; Quasi-dynamic simulation; Level walking; ELASTIC-MODULUS; COMPLICATIONS; FEMUR;
D O I
10.1186/s13018-022-03482-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: A minimally invasive technique with various screw configurations without open surgery is currently used for the fixation of transverse patellar fractures. Percutaneous crossing screw configuration has been reported to have a good bone union rate in patellar fractures. However, the difference in mechanical stability of the fractured patella between different screw-included angles has not been fully investigated. Hence, this study aims to compare the mechanical stability of parallel and crossing screw fixations with different screw-included angles for the fixation of transverse patellar fractures during level walking. Methods: A finite element knee model containing a patella with a transverse fracture is created. Two headless compression screws with different angles (0 degrees, 30 degrees, 60 degrees, and 90 degrees) are used to fix the fracture. The loading conditions of the knee joint during level walking are used to compare the stability of the fractured patella with different fixation screw configurations. Results: The results indicate that the maximum fracture gap opening distance increased with an increase in the included angle. Two parallel screws yield the smallest gap distance among all screw configurations. The maximum gap opening distances at the anterior leading edge of the fractured patella with two parallel screws and two screws having an included angle of 90 degrees are 0.73 mm and 1.31 mm, respectively, at 15% walking cycle. Conclusions: Based on these results, the superior performance of two parallel screws over crossing screw fixations in the fixation of transverse patellar fractures is established. Furthermore, the smaller the angle between the crossing screws, the better is the stability of the fractured patella.
引用
收藏
页数:10
相关论文
共 15 条
  • [1] Biomechanical comparison of different screw-included angles in crossing screw fixation for transverse patellar fracture in level walking: a quasi-dynamic finite element study
    Chih-Wei Chang
    Yen-Nien Chen
    Hung-Chih Chang
    Chun-Ting Li
    Journal of Orthopaedic Surgery and Research, 18
  • [2] Biomechanical comparison using finite element analysis of different screw configurations in the fixation of femoral neck fractures
    Gok, K.
    Inal, S.
    MECHANICAL SCIENCES, 2015, 6 (02) : 173 - 179
  • [3] BIOMECHANICAL EFFECT OF DIFFERENT LAG SCREW LENGTHS WITH DIFFERENT BARREL LENGTHS IN DYNAMIC HIP SCREW SYSTEM: A FINITE ELEMENT ANALYSIS STUDY
    Tzeng, Chung-Yuh
    Huang, Kui-Chuo
    Wu, Yun-Che
    Chang, Chu-Ling
    Lee, Kuan-Rong
    Su, Kuo-Chih
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2017, 17 (01)
  • [4] Comparison of Pedicle Screw Fixation Strength Among Different Transpedicular Trajectories A Finite Element Study
    Matsukawa, Keitaro
    Yato, Yoshiyuki
    Hynes, Richard A.
    Imabayashi, Hideaki
    Hosogane, Naobumi
    Yoshihara, Yasuo
    Asazuma, Takashi
    Nemoto, Koichi
    CLINICAL SPINE SURGERY, 2017, 30 (07): : 301 - 307
  • [5] A comparative Study of Novel Extramedullary Fixation and Dynamic Hip Screw in the Fixation of Intertrochanteric Fracture: A Finite-Element Analysis
    Ding, Kai
    Zhu, Yanbin
    Wang, Haicheng
    Li, Yonglong
    Yang, Weijie
    Cheng, Xiaodong
    Zhang, Yingze
    Chen, Wei
    Zhang, Qi
    FRONTIERS IN SURGERY, 2022, 9
  • [6] Comparison of the biomechanical effects of pertrochanteric fixator and dynamic hip screw on an intertrochanteric femoral fracture using the finite element method
    Inal, Sermet
    Taspinar, Ferruh
    Gulbandilar, Eyyup
    Gok, Kadir
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2015, 11 (01): : 95 - 103
  • [7] Comparative biomechanical study of different screw fixation methods for minimally invasive hallux valgus surgery: A finite element analysis
    Lewis, T. L.
    Mansur, H.
    Ferreira, G. F.
    Filho, M. V. P.
    Battaglion, L. R.
    Zambelli, R.
    Ray, R.
    Nunes, G. A.
    FOOT AND ANKLE SURGERY, 2025, 31 (02) : 160 - 169
  • [8] Biomechanical comparison of dynamic hip screw and Gamma nail for the treatment of unstable trochanteric fractures: a finite element study
    Huang, Xiaowei
    Yu, Baoqing
    Gu, Yong
    Li, Zexiang
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (05): : 7867 - 7874
  • [9] Biomechanical comparison of posterior intermediate screw fixation techniques with hybrid monoaxial and polyaxial pedicle screws in the treatment of thoracolumbar burst fracture: a finite element study
    Liu, Huan
    Wang, Hongwei
    Liu, Jun
    Li, Changqing
    Zhou, Yue
    Xiang, Liangbi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14
  • [10] Biomechanical comparison of posterior intermediate screw fixation techniques with hybrid monoaxial and polyaxial pedicle screws in the treatment of thoracolumbar burst fracture: a finite element study
    Huan Liu
    Hongwei Wang
    Jun Liu
    Changqing Li
    Yue Zhou
    Liangbi Xiang
    Journal of Orthopaedic Surgery and Research, 14