Agreement between invasive and noninvasive measurement of tear film breakup time

被引:0
|
作者
Szczesna-Iskander, Dorota H. [1 ]
Llorens-Quintana, Clara [2 ]
机构
[1] Wroclaw Univ Sci & Technol, Fac Fundamental Problems Technol, Dept Opt & Photon, Wybrzeze Wyspianskiego 27, PL-50370 Wroclaw, Poland
[2] Univ Complutense Madrid, Fac Opt & Optometry, Dept Optometry & Vis, Madrid, Spain
关键词
DRY EYE; REPEATABILITY; STABILITY; TBUT;
D O I
10.1038/s41598-024-54219-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The agreement between fluorescein breakup time (FBUT) estimates and noninvasive breakup time (NIBUT) estimates automatically acquired using two videokeratoscopes was assessed. Small-cone (E300, Medmont) and large-bowl (K5M, OCULUS) Placido-ring-based videokeratoscopes were utilized for automated NIBUT estimation and fluorescein strip method was used for FBUT estimation. 33 subjects completed the study. Clear instructions were given regarding the blink before measurements. Bland-Altman analysis was used to test the agreement between tear film breakup time estimates and repeated measure analysis of variance was used to test the differences between measurement types. In comparison to FBUT, E300 NIBUT estimate was shorter (- 0.6 +/- 2.6 s), whereas K5M NIBUT estimate was longer (3.3 +/- 2.4 s). Limits of agreement for FBUT vs. E300 was 29.8 s, for FBUT vs. K5M 26.4 s, and 31.4 s for E300 vs. K5M. There were significant differences between tear film breakup times (F = 3.59, df = 2, P = 0.032). E300 and K5M NIBUT measurements have poor agreement with FBUT, even when blinking is precisely clarified. Agreement was better for shorted break up times than that for longer ones but in general NIBUT measurements are not interchangeable.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Clinical observation of tear film breakup time with a novel smartphone-attachable technology
    Xiaoran Zhang
    Jiawei Shen
    Zhen Kang
    Andrew Chen
    Qian Cao
    Chunyan Xue
    BMC Ophthalmology, 23
  • [42] NONINVASIVE MEASUREMENT OF TEAR OXYGEN IN RABBITS
    HARVITT, DM
    BONANNO, JA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 980 - 980
  • [43] Artificial intelligence to estimate the tear film breakup time and diagnose dry eye disease
    Shimizu, Eisuke
    Ishikawa, Toshiki
    Tanji, Makoto
    Agata, Naomichi
    Nakayama, Shintaro
    Nakahara, Yo
    Yokoiwa, Ryota
    Sato, Shinri
    Hanyuda, Akiko
    Ogawa, Yoko
    Hirayama, Masatoshi
    Tsubota, Kazuo
    Sato, Yasunori
    Shimazaki, Jun
    Negishi, Kazuno
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [44] Clinical observation of tear film breakup time with a novel smartphone-attachable technology
    Zhang, Xiaoran
    Shen, Jiawei
    Kang, Zhen
    Chen, Andrew
    Cao, Qian
    Xue, Chunyan
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [45] Artificial intelligence to estimate the tear film breakup time and diagnose dry eye disease
    Eisuke Shimizu
    Toshiki Ishikawa
    Makoto Tanji
    Naomichi Agata
    Shintaro Nakayama
    Yo Nakahara
    Ryota Yokoiwa
    Shinri Sato
    Akiko Hanyuda
    Yoko Ogawa
    Masatoshi Hirayama
    Kazuo Tsubota
    Yasunori Sato
    Jun Shimazaki
    Kazuno Negishi
    Scientific Reports, 13
  • [46] The comparison of 3 different methods used for the evaluation of precorneal tear film breakup time
    Niu, Mengxi
    Yokoi, Norihiko
    Kato, Hiroaki
    Sakai, Rieko
    Komuro, Aoi
    Sonomura, Yukiko
    Koizumi, Noriko
    Kinoshita, Shigeru
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [47] Impact of Soft Contact Lens Wear on Tear Film Breakup Patterns, Meniscus Tear Volume, and Tear Film Stability
    Yokoi, Norihiko
    Sakai, Rieko
    Georgiev, Georgi As
    Kato, Hiroaki
    Sotozono, Chie
    Kinoshita, Shigeru
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [48] Automated Tear Film Surface Quality Breakup Time as a Novel Clinical Marker for Tear Hyperosmolarity in Dry Eye Disease
    Downie, Laura Elizabeth
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (12) : 7260 - 7268
  • [49] FACTORS AFFECTING TEAR FILM BREAKUP IN NORMAL EYES
    LEMP, MA
    HAMILL, JR
    ARCHIVES OF OPHTHALMOLOGY, 1973, 89 (02) : 103 - 105
  • [50] Analysis of tear film breakup on Etafilcon A hydrogel lenses
    Bruce, AS
    Mainstone, JC
    Golding, TR
    BIOMATERIALS, 2001, 22 (24) : 3249 - 3256