Optimal Placement and Active Control Methods for Integrating Smart Material in Dynamic Suppression Structures

被引:0
|
作者
Moutsopoulou, Amalia [1 ]
Stavroulakis, Georgios E. [2 ]
Petousis, Markos [1 ]
Pouliezos, Anastasios [2 ]
Vidakis, Nectarios [1 ]
机构
[1] Hellen Mediterranean Univ, Dept Mech Engn, Iraklion 71410, Greece
[2] Tech Univ Crete, Dept Prod Engn & Management, Kounoupidianna 73100, Chania, Greece
来源
VIBRATION | 2023年 / 6卷 / 04期
关键词
optimal placement; robust control; smart materials; H-infinity control; VIBRATION CONTROL; ROBUST-CONTROL; FEEDBACK; SENSOR/ACTUATOR; OPTIMIZATION; PERFORMANCE; SENSORS; BEAMS;
D O I
10.3390/vibration6040058
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
To simulate a lightweight structure with integrated actuators and sensors, two-dimensional finite elements are utilized. The study looks at the optimal location and active vibration control for a piezoelectric smart flexible structure. Intelligent applications are commonly used in engineering applications. In computational mechanics, selecting the ideal position for actuators to suppress oscillations is crucial. The structure oscillates due to dynamic disturbance, and active control is used to try to reduce the oscillation. Utilizing an LQR and H-infinity controller, optimization is carried out to determine the best controller weights, which will dampen the oscillation. Challenging issues arise in the design of control techniques for piezoelectric smart structures. Piezoelectric materials have been investigated for use in distributed parameter systems (for example airplane wings, intelligent bridges, etc.) to provide active control efficiently and affordably. Still, no full suppression of the oscillation with this approach has been achieved so far. The controller's order is then decreased using optimization techniques. Piezoelectric actuators are positioned optimally according to an enhanced optimization method. The outcomes demonstrate that the actuator optimization strategies used in the piezoelectric smart single flexible manipulator system have increased observability in addition to good vibration suppression results.
引用
收藏
页码:975 / 1003
页数:29
相关论文
共 50 条
  • [31] Optimal control of adaptive/smart bridge structures
    Adeli, H
    Saleh, A
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1997, 123 (02): : 218 - 226
  • [32] Optimal control problems in the theory of smart structures
    Golubin, AY
    Kalamkarov, AL
    SMART MATERIALS & STRUCTURES, 2000, 9 (02): : 226 - 234
  • [33] Optimal sizing and placement of piezo-actuators for active flutter suppression
    Nam, C
    Kim, Y
    Weisshaar, TA
    SMART MATERIALS & STRUCTURES, 1996, 5 (02): : 216 - 224
  • [34] Active vibration control and suppression for integrated structures
    Zhongdong W.
    Suhuan C.
    Xiaodong Y.
    Applied Mathematics and Mechanics, 1999, 20 (2) : 171 - 178
  • [35] Active vibration control and suppression for integrated structures
    Wang, ZD
    Chen, SH
    Yang, XD
    APPLIED MATHEMATICS AND MECHANICS-ENGLISH EDITION, 1999, 20 (02) : 171 - 178
  • [36] ACTIVE VIBRATION CONTROL AND SUPPRESSION FOR INTEGRATED STRUCTURES
    王忠东
    陈塑寰
    杨晓东
    AppliedMathematicsandMechanics(EnglishEdition), 1999, (02) : 171 - 178
  • [37] Active vibration control and suppression for intelligent structures
    Chen, SH
    Wang, ZD
    Liu, XH
    JOURNAL OF SOUND AND VIBRATION, 1997, 200 (02) : 167 - 177
  • [38] Active vibration control of buildings with smart structures
    Fujita, T
    INTERNATIONAL JOURNAL OF THE JAPAN SOCIETY FOR PRECISION ENGINEERING, 1998, 32 (03): : 160 - 165
  • [39] Optimal placement of actuators in active control of cylindrical shells
    Hu Z.-C.
    He L.
    Li Y.
    Chuan Bo Li Xue/Journal of Ship Mechanics, 2019, 23 (11): : 1376 - 1386
  • [40] OPTIMAL PLACEMENT OF SOURCES FOR ACTIVE NOISE-CONTROL
    SERGENT, P
    ACTA ACUSTICA, 1995, 3 (01): : 47 - 57