摘要
Background: Ultrafiltration (UF) is an extracorporeal technique for treating fluid overload and is monitored with noninvasive blood volume monitors.Hypothesis/Objectives: The primary objective was to determine the accuracy of Crit-Line (R) III and IV noninvasive blood volume monitors to estimate canine packed cell volume (PCV) and changes in blood volume during UF. A secondary aim was to determine accuracy of targeted ultrafiltration rates (UFR) compared to calculated delivered UFR.Methods: An ex vivo study with a single Phoenix (R) X36 platform and canine packed red blood cells (pRBC) was performed. Through dilution and UF, clinically applicable PCV values were obtained and compared to Crit-Line (R) hematocrit (Hct). Blood volume was constantly measured and compared to targeted UFR. Systematic and proportional bias were calculated using a Bayes method.Results: Crit-Line (R) III and IV reported Hct was significantly lower than PCV (n = 140, median 26%, range, 8%-50%) when PCV was >25% and >30%, respectively. Crit-Line (R) III and IV calculated change in blood volume (Delta BV%) was significantly different from measured blood volume changes at Delta BV%+/- 20% and >-20%, respectively. Comparing targeted and delivered UFR (mL/h), less than targeted UFR was removed at UFR100 through UFR400 and UFR0 adding volume.Conclusions and Clinical Importance: Crit-Line (R) III and IV monitors provide accurate estimates of canine PCV and UF volume change within specific ranges and are useful in monitoring canine UF and hemodialysis. Veterinary hemodialysis services should evaluate individual machines for UFR inaccuracies, which can meaningfully affect small animals.
引用
收藏
页码:2137 / 2144
页数:8
相关论文
共 23 条
  • [1] CRIT-LINE BLOOD VOLUME MONITORING IN A COMMUNITY HEMODIALYSIS UNIT
    Dukes, Carl
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2020, 75 (04) : 564 - 564
  • [2] Assessment of dry weight by monitoring changes in blood volume during hemodialysis using Crit-Line
    Rodriguez, HJ
    Domenici, R
    Diroll, A
    Goykhman, I
    KIDNEY INTERNATIONAL, 2005, 68 (02) : 854 - 861
  • [3] Blood volume (BV) change monitored by Crit-line IIR (In-Line Diagnostics, USA) during various sodium ramping in hemodialysis D(HD).
    Ma, KA
    Kim, HS
    Kim, SJ
    Kim, SD
    Jee, SB
    Shin, GT
    Kim, DH
    KIDNEY INTERNATIONAL, 1999, 55 (04) : 1615 - 1615
  • [4] Evaluation of BRAT 2 CRIT-LINE hematocrit measurement system for quality control of perioperatively salvaged blood
    Santrach, PJ
    Willis, EA
    McMartin, DR
    Mathison, BA
    TRANSFUSION, 2001, 41 (09) : 100S - 101S
  • [5] Crit-Line Monitoring Effect on Blood Pressure Control in ESRD Patients Undergoing In-Center Hemodialysis
    Meier, Maggie
    Iftikhar, Hassaan
    Li, Alexandria Y.
    Brien, Frank J. O.
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2021, 32 (10): : 552 - 552
  • [6] Monitoring of body water composition by the simultaneous use of bioelectrical impedance analysis and Crit-Line® during hemodialysis
    Naoki Sugano
    Keitaro Yokoyama
    Naohiko Kato
    Yoichiro Hara
    Satoshi Endo
    Jun Mitome
    Taisei Kin
    Goro Tokudome
    Satoru Kuriyama
    Tatsuo Hosoya
    Takashi Yokoo
    Clinical and Experimental Nephrology, 2014, 18 : 944 - 951
  • [7] Continuous noninvasive in vivo monitoring of intravascular plasma volume and hematocrit changes during hemodialysis in humans: direct comparison with the CRIT-LINE.
    Deng, Bin
    Kastner, Evan
    Narsipur, Sriram S.
    Goodisman, Jerry
    Chaiken, J.
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC AND SURGICAL GUIDANCE SYSTEMS XII, 2014, 8935
  • [8] On-line dynamic measurement of blood viscosity, hematocrit and change of blood volume
    尹志勇
    周继红
    蔡绍皙
    王正国
    ChineseJournalofTraumatology, 2000, (02)
  • [9] On-line dynamic measurement of blood viscosity, hematocrit and change of blood volume
    尹志勇
    周继红
    蔡绍皙
    王正国
    中华创伤杂志(英文版), 2000, (02) : 38 - 42
  • [10] Diagnosis of Obstructive Sleep Apnea (OSA) Using NightOne (Nite1) and Crit-Line (CLD) Devices During In-Center Hemodialysis
    Iftikhar, Hassaan
    Newberry, Katherine P.
    Brien, Frank J. O.
    Coyne, Daniel W.
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2022, 33 (11): : 698 - 699