Platelet Bacterial Detection Experience with BACT/ALERT VIRTUO versus BACT/ALERT 3D

被引:0
|
作者
Vassallo, R. [1 ]
Castro, K. [1 ]
James, J. [1 ]
Sanchez, J. [1 ]
Tysarczyk, M. [1 ]
机构
[1] Vitalant, Denver, CO USA
关键词
D O I
10.1111/trf.283_17554
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
P-IS-6
引用
收藏
页码:216A / 217A
页数:2
相关论文
共 50 条
  • [21] Large Volume Delayed Sampling Using the Bact/ALERT Virtuo Microbial Detection System
    Requena, Horacio
    Langford, Melissa
    Prichard, Alicia Bellido
    Gammon, Richard R.
    TRANSFUSION, 2022, 62 : 61A - 61A
  • [22] In vitro Evaluation of BACT/ALERT® VIRTUO®, BACT/ALERT 3D®, and BACTEC™ FX Automated Blood Culture Systems for Detection of Microbial Pathogens Using Simulated Human Blood Samples (vol 10, 221, 2019)
    Menchinelli, Giulia
    Liotti, Flora Marzia
    Fiori, Barbara
    De Angelis, Giulia
    D'Inzeo, Tiziana
    Giordano, Liliana
    Posteraro, Brunella
    Sabbatucci, Michela
    Sanguinetti, Maurizio
    Spanu, Teresa
    FRONTIERS IN MICROBIOLOGY, 2019, 10
  • [23] Multicenter Clinical Evaluation of BacT/Alert Virtuo Blood Culture System
    Jacobs, Michael R.
    Mazzulli, Tony
    Hazen, Kevin C.
    Good, Caryn E.
    Abdelhamed, Ayman M.
    Lo, Pauline
    Shum, Bianche
    Roman, Katharine P.
    Robinson, Danielle C.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2017, 55 (08) : 2413 - 2421
  • [24] Accuracy of BacT/Alert Virtuo for Measuring Blood Volume for Blood Culture
    Lee, Seungjun
    Kim, Sunjoo
    ANNALS OF LABORATORY MEDICINE, 2019, 39 (06) : 590 - 592
  • [25] Time to Detection with BacT/Alert FA Plus Compared to BacT/Alert FA Blood Culture Media
    Nutman, A.
    Even-Tsur, S. Fisher
    Shapiro, G.
    Braun, T.
    Schwartz, D.
    Carmeli, Y.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2016, 35 (09) : 1469 - 1473
  • [26] Time to Detection with BacT/Alert FA Plus Compared to BacT/Alert FA Blood Culture Media
    A. Nutman
    S. Fisher Even-Tsur
    G. Shapiro
    T. Braun
    D. Schwartz
    Y. Carmeli
    European Journal of Clinical Microbiology & Infectious Diseases, 2016, 35 : 1469 - 1473
  • [27] Time-to-detection of bacteria and yeast with the BACTEC FX versus BacT/Alert Virtuo blood culture systems
    Somily, Ali Mohammed
    Babay, Hanan Ahmed Habib
    Torchyan, Armen Albert
    Sayyed, Samina B.
    Absar, Muhammed
    Al-Aqeel, Rima
    Binkhamis, Khalifa
    ANNALS OF SAUDI MEDICINE, 2018, 38 (03) : 194 - 199
  • [28] Brucella detection in blood:: comparison of the BacT/Alert standard aerobic bottle, BacT/Alert FAN aerobic bottle and BacT/Alert enhanced FAN aerobic bottle in simulated blood culture
    Sümerkan, B
    Gökahmetoglu, S
    Esel, D
    CLINICAL MICROBIOLOGY AND INFECTION, 2001, 7 (07) : 369 - 372
  • [29] VALIDATION AND COMPARISON OF AEROBIC AND ANAEROBIC BACTERIA, YEAST AND MOULD DETECTION USING THE BACT/ALERT® 3D™ AND VIRTUO™ SYSTEMS FOR HAEMATOPOIETIC PROGENITOR CELLS (HPC)
    Wright, C.
    Allerton, J.
    Kabani, K.
    Zarkos, K.
    CYTOTHERAPY, 2021, 23 (05) : S83 - S84
  • [30] Controlled Evaluation of the New BacT/Alert Virtuo Blood Culture System for Detection and Time to Detection of Bacteria and Yeasts
    Altun, Osman
    Almuhayawi, Mohammed
    Luthje, Petra
    Taha, Rubina
    Ullberg, Mans
    Ozenci, Volkan
    JOURNAL OF CLINICAL MICROBIOLOGY, 2016, 54 (04) : 1148 - 1151