A flexible carbon nanofiber and conjugated polymer-based electrode for glucose sensing

被引:12
|
作者
Bulut, Umut [1 ]
Sayin, Vuslat Oyku [1 ]
Altin, Yasin [2 ]
Cevher, Sevki Can [3 ]
Cirpan, Ali [4 ,5 ,6 ,7 ]
Bedeloglu, Ayse Celik [2 ]
Soylemez, Saniye [8 ]
机构
[1] Acibadem Mehmet Ali Aydinlar Univ, Dept Analyt Chem, Fac Pharm, Istanbul, Turkiye
[2] Bursa Tech Univ, Dept Polymer Mat Engn, Bursa, Turkiye
[3] Sivas Univ Sci & Technol, Dept Engn Fundamental Sci, Sivas, Turkiye
[4] Middle East Tech Univ, Dept Chem, Fac Sci, Ankara, Turkiye
[5] Middle East Tech Univ, Dept Polymer Sci & Technol, TR-06800 Ankara, Turkiye
[6] Middle East Tech Univ, Ctr Solar Energy Res & Applicat GUNAM, Ankara, Turkiye
[7] Middle East Tech Univ, Dept Micro & Nanotechnol, TR-06800 Ankara, Turkiye
[8] Necmettin Erbakan Univ, Dept Biomed Engn, Fac Engn, Konya, Turkiye
关键词
Glucose detection; Carbon nanofiber; Conjugated random polymer; Enzyme immobilization; Glucose oxidase; CONDUCTING POLYMER; SIDE-CHAINS; PERFORMANCE; NANOTUBES; NANOTECHNOLOGY; STABILIZATION; TRANSISTORS; REDUCTION; BIOSENSOR; PLATFORM;
D O I
10.1016/j.microc.2022.108148
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Herein, a specific and stable biosensor for glucose using a flexible, modified electrode with a carbon nanofiber (CNF) and a novel conjugated polymer including three moieties of benzotriazole, benzodithiophene, and benzenediamine (P-BDT-BTz:BDA) as a platform was designed. For this purpose, polyacrylonitrile (PAN) nanofiber mats were obtained by a solution-based electrospinning method. PAN nanofiber mats were stabilized and carbonized to turn into carbon nanofibers and the sensing platform was formed by combining the nanofibers on a defined area of a flexible polyethylene terephthalate (PET) substrate. In addition, a random conjugated polymer, P-BDT-BTz:BDA, was synthesized, characterized, and used as a modifier of a CNF-coated transducer surface for glucose detection. The effect of each parameter on biosensor response was evaluated. Under optimized conditions, the electrode responded to glucose in a linear concentration range of 20 mu M to 500 mu M with a detection limit of 8.5 mu M. In addition, it was observed that the designed biosensor has a good sensing ability for glucose in beverages. The results of our study show that the proposed amperometric glucose oxidase (GOx)-based biosensor has high specificity, a low limit of detection, and an extended range of linear detection for glucose.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] A review on conjugated polymer-based electronic tongues
    Vahdatiyekta, Parastoo
    Zniber, Mohammed
    Bobacka, Johan
    Huynh, Tan-Phat
    ANALYTICA CHIMICA ACTA, 2022, 1221
  • [22] Light Management or Conjugated Polymer-Based Photovoltaics
    O'Carroll, Deirdre M.
    2013 IEEE 39TH PHOTOVOLTAIC SPECIALISTS CONFERENCE (PVSC), 2013, : 2742 - 2745
  • [23] Conjugated polymer-based light emitting diodes
    Towns, C. R.
    Grizzi, I.
    Roberts, M.
    Wehrum, A.
    JOURNAL OF LUMINESCENCE, 2007, 122 : 976 - 979
  • [24] Electrospun polymer-based nanofiber scaffolds for skin regeneration
    Arida, Islam A.
    Ali, Isra H.
    Nasr, Maha
    El-Sherbiny, Ibrahim M.
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2021, 64
  • [25] Conjugated schiff base polymer foam/macroporous carbon integrated electrode for electrochemical sensing
    Wang, Linyu
    Gong, Coucong
    Shen, Yuan
    Xu, Mengli
    He, Guanghua
    Wang, Li
    Song, Yonghai
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 265 : 227 - 233
  • [26] Conjugated Polymer-Based Nanocomposites for Pressure Sensors
    Lai, Qin-Teng
    Sun, Qi-Jun
    Tang, Zhenhua
    Tang, Xin-Gui
    Zhao, Xin-Hua
    MOLECULES, 2023, 28 (04):
  • [27] Conjugated polymer-based organic solar cells
    Guenes, Serap
    Neugebauer, Helmut
    Sariciftci, Niyazi Serdar
    CHEMICAL REVIEWS, 2007, 107 (04) : 1324 - 1338
  • [28] Polymer-Based Technologies for Sensing Applications
    Carvalho, Wildemar S. P.
    Wei, Menglian
    Ikpo, Nduka
    Gao, Yongfeng
    Serpe, Michael J.
    ANALYTICAL CHEMISTRY, 2018, 90 (01) : 459 - 479
  • [29] Increased Energy Density with Conjugated Polymer-Based Composite Electrode without Power Density Sacrifice
    He, Shanshan
    Muslim, Arzugul
    Adili, Guliqire
    Rahmat, Salima
    He, Tingting
    Yao, Rui
    ACS APPLIED POLYMER MATERIALS, 2024, 6 (17): : 10178 - 10192
  • [30] Fabrication of polymer-based flexible tactile sensing module with metal strain gauges and interconnecter
    Lee, Kang Ryeol
    Kim, Kunnyun
    Kim, Yong-Kook
    Lee, Dae-Sung
    Kim, Won Hyo
    Cho, Nam-Kyu
    Park, Kwang-Bum
    Shin, Kyu-Sik
    Park, Hyo-Derk
    2006 IEEE SENSORS, VOLS 1-3, 2006, : 742 - +