Correction of ring artifacts with Swin-Conv-U-Net for x-ray computed tomography

被引:1
|
作者
Fu, Tianyu [1 ,2 ]
Qiu, Sen [1 ,2 ]
Wang, Yan [1 ,2 ]
Zhang, Kai [1 ,2 ]
Zhang, Jin [1 ]
Wang, Shanfeng [1 ]
Huang, Wanxia [1 ]
Zhou, Chenpeng [1 ,2 ]
Zhao, XinYu [1 ,2 ]
Tao, Ye [1 ]
Yuan, Qingxi [1 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, Xray Opt & Technol Lab, Beijing Synchrotron Radiat Facil, Yuquan Rd, Beijing 100049, Peoples R China
[2] Univ Chinese Acad Sci, Yuquan Rd, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
WAVELET; STRIPE;
D O I
10.1063/5.0136961
中图分类号
O59 [应用物理学];
学科分类号
摘要
X-ray tomography is widely used in diverse research domains owing to its capacity for observing high-resolution three-dimensional structures nondestructively. However, ring artifacts appear in the tomographic reconstruction because of the inconsistent response of detector pixels, seriously affecting the image quality and causing nonuniform bias. To solve this problem, a method for correction of ring artifacts based on Swin-Conv-U-Net is proposed for x-ray tomography. When applied to simulation and experimental data, the proposed method achieves high accuracy and strong robustness and shows advantages over several classical methods in quantitative and qualitative evaluation.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] U-Net-based image segmentation of the whole heart and four chambers on pediatric X-ray computed tomography
    Yoshida, Akifumi
    Kondo, Yohan
    Yoshimura, Norihiko
    Kuramoto, Tatsuya
    Hasegawa, Akira
    Kanazawa, Tsutomu
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2022, 15 (02) : 156 - 169
  • [42] Cupping artifacts correction for polychromatic X-ray cone-beam computed tomography based on projection compensation and hardening behavior
    Yang, Fuqiang
    Zhang, Dinghua
    Zhang, Hua
    Huang, Kuidong
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 57
  • [43] ASSESSMENT OF THE CONFIGURATION OF ATRIOVENTRICULAR VALVULAR RING BY X-RAY COMPUTED-TOMOGRAPHY
    NAITO, H
    OHTA, M
    KIMURA, K
    TAKAMIYA, M
    KOZUKA, T
    FUJITA, T
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1984, 48 (08): : 764 - 764
  • [44] X-ray computed tomography using projection X-ray microscope
    Yoshimura, F
    Miyata, C
    Kuzuryu, C
    Hori, A
    Obi, T
    Ohyama, N
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 166 - 171
  • [45] Application of Segmentation for Correction of Intensity Bias in X-Ray Computed Tomography Images
    Iassonov, Pavel
    Tuller, Markus
    VADOSE ZONE JOURNAL, 2010, 9 (01) : 187 - 191
  • [46] Beam hardening correction for X-ray computed tomography of heterogeneous natural materials
    Ketcham, Richard A.
    Hanna, Romy D.
    COMPUTERS & GEOSCIENCES, 2014, 67 : 49 - 61
  • [47] Fast Correction of Analytical Reconstructions in Sparse View X-ray Computed Tomography
    Trinca, D.
    Zhong, Y.
    Royuela-del-Val, J.
    2017 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM - SPRING (PIERS), 2017, : 1109 - 1115
  • [48] Correction of center of rotation and projection angle in synchrotron X-ray computed tomography
    Chang-Chieh Cheng
    Yu-Tai Ching
    Pai-Hung Ko
    Yeukuang Hwu
    Scientific Reports, 8
  • [49] Statistical X-ray computed tomography image reconstruction with beam hardening correction
    Elbakri, IA
    Fessler, JA
    MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 1 - 12
  • [50] Correction of center of rotation and projection angle in synchrotron X-ray computed tomography
    Cheng, Chang-Chieh
    Ching, Yu-Tai
    Ko, Pai-Hung
    Hwu, Yeukuang
    SCIENTIFIC REPORTS, 2018, 8