An experimental framework for assessing the detective quantum efficiency of spectroscopic x-ray detectors

被引:3
|
作者
Zarif Yussefian, Nikta [1 ,2 ]
Tanguay, Jesse [1 ]
机构
[1] Toronto Metropolitan Univ, Dept Phys, Toronto, ON, Canada
[2] Toronto Metropolitan Univ, Dept Phys, Toronto, ON M5B 2K3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
detective quantum efficiency; modulation transfer function; noise power spectrum; photon-counting; spectral imaging; COMPUTED-TOMOGRAPHY; MODEL;
D O I
10.1002/mp.16114
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundAssessing the performance of spectroscopic x-ray detectors (SXDs) requires measurement of the frequency-dependent detective quantum efficiency (DQE). Analytical expressions of the task-based DQE and task-independent DQE of SXDs have been presented in the literature, but standardizable experimental methods for measuring them have not. The task-based DQE quantifies the efficiency with which an SXD uses the x-ray quanta incident upon it to either quantify or detect a basis material (e.g., soft tissue or bone) of interest. The task-independent DQE is akin to the conventional DQE in that it is independent of the basis material to be detected or quantified. PurposeThe purpose of this paper is to develop an experimental framework to present a method for experimental analysis of the DQE of SXDs, including the task-based DQE and task-independent DQE. MethodsWe develop methods to measure the frequency-dependent DQE for task of quantifying or detecting a perturbation in a known basis material. We also develop methods for measuring a task-independent DQE. We show that the task-based DQEs and the task-independent DQE can be measured using a modest extension of the methods prescribed by International Electrotechnical Commission (IEC). Specifically, measuring the task-independent DQE requires measuring the modulation transfer function (MTF) and noise power spectrum (NPS) of each energy-bin image, in addition to the cross NPS between energy-bin images. Measuring the task-based DQEs requires an additional measurement of the transmission fraction through a thin basis-material absorber. We implemented the developed methods using standardized IEC x-ray spectra, aluminum (Al) and polymethyl methacrylyte (PMMA) basis materials, and a cadmium telluride (CdTe) SXD equipped with two energy bins and analog charge summing (ACS) for charge-sharing suppression. We also performed a regression analysis to determine whether or not the task-independent DQE is predictive of the task-based DQEs. ResultsExperimental results of the task-based DQEs were consistent with simulation results presented in the literature. In general, and as expected, ACS increased the task-based DQEs and task-independent DQE. This effect was most pronounced for quantification tasks, in some instances yielding a five-fold increase in the DQE. For both spectra, with and without ACS for charge sharing correction, the task-based DQEs were linearly related to the task-independent DQE, as demonstrated by R-2-values ranging from 0.89 to 1.00. ConclusionsWe have extended experimental DQE analysis to SXDs that count photons in multiple energy bins in a single x-ray exposure. The developed framework is an extension of existing IEC methods, and provides a standardized approach to assessing the performance of SXDs.
引用
收藏
页码:1318 / 1335
页数:18
相关论文
共 50 条
  • [31] Measurement of the detective quantum efficiency (DQE) of digital X-ray detectors according to the novel standard IEC 62220-1
    Illers, H
    Buhr, E
    Hoeschen, C
    RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 39 - 44
  • [32] Monte-Carlo Simulation of the Detective Quantum Efficiency of Cadmium Telluride X-Ray Detectors for Photon-Counting Mammography
    Day, J.
    Tanguay, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [33] Dependence of the detective quantum efficiency of photoconductive x-ray image detectors on charge transport parameters and exposure:: Application to a-Se
    Kasap, SO
    Kabir, MZ
    Rowlands, JA
    Tousignant, O
    Leboeuf, J
    Laperrière, L
    Demers, Y
    APPLIED PHYSICS LETTERS, 2002, 81 (18) : 3482 - 3484
  • [34] The X-ray response of CdZnTe detectors to be used as future spectroscopic detectors for X-ray astronomy
    Kraft, S
    Bavdaz, M
    Castelletto, B
    Peacock, A
    Scholze, F
    Ulm, G
    Gagliardi, MA
    Nenonen, S
    Tuomi, T
    Juvonen, M
    Rantamaki, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 418 (2-3): : 337 - 347
  • [35] Detective quantum efficiency model of single-X-ray-photon counting hybrid pixel detectors
    Marchal, Julien
    Medjoubi, Kadda
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [36] Soft x-ray quantum efficiency of Silicon hybrid CMOS detectors
    Prieskorn, Zachary R.
    Bongiorno, Stephen D.
    Burrows, David N.
    Falcone, Abraham D.
    Griffith, Christopher V.
    Nikoleyczik, Jonathan
    HIGH ENERGY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY VI, 2014, 9154
  • [37] Spectroscopic model for SiC X-ray detectors
    Lees, J. E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 613 (01): : 98 - 105
  • [38] Analysis of factors affecting the estimation of detective quantum efficiency of digital X-ray detectors within high and low spatial frequency ranges
    Zelikman M.I.
    Kabanov S.P.
    Kruchinin S.A.
    Lobov D.P.
    Biomedical Engineering, 2007, 41 (5) : 210 - 213
  • [39] Modelling of detective quantum efficiency of direct conversion x-ray imaging detectors incorporating charge carrier trapping and K-fluorescence
    Kabir, M. Z.
    Rahman, M. W.
    Shen, W. Y.
    IET CIRCUITS DEVICES & SYSTEMS, 2011, 5 (03) : 222 - 231
  • [40] Monitoring of quantum efficiency of digital x-ray detectors based on photostimulated luminophores
    Zelikman M.I.
    Kabanov S.P.
    Kruchinin S.A.
    Lobov D.P.
    Biomedical Engineering, 2008, 42 (5) : 249 - 252