Trace element analysis in lithium matrices using micro-discharge optical emission spectroscopy

被引:3
|
作者
Wiggershaus, Bastian [1 ]
Jeskanen, Miisamari [2 ]
Roos, Aappo [2 ]
Vogt, Carla [1 ]
Laurila, Toni [2 ]
机构
[1] TU Bergakad Freiberg, Inst Analyt Chem, Lessingstr 45, D-09599 Freiberg, Germany
[2] Sensmet Oy, Customer Applicat Ctr, Otakaari 7, Espoo 02150, Finland
关键词
ATMOSPHERIC-PRESSURE; VAPOR GENERATION; PLASMA; SPECTROMETRY; CATHODE; HG; SB;
D O I
10.1039/d4ja00044g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The increasing demand for high purity battery elements and the necessity to reliably determine trace concentrations of impurity metals have triggered recent development of new analytical methods. Both in battery metal production and recycling there is a growing need for new fast, precise and easy-to-use analytical methods, especially for the on-line and on-site analysis of lithium salt solutions, whose derivative products are used in the battery industry. Typically used established techniques, such as ICP-OES or ICP-MS, are usually limited to laboratory use due to high plasma gas flow rates and power consumption, making them unsuitable for real-time analysis and monitoring of industrial processes on-site. Therefore, a fast and precise on-site method which allows trace element analysis would be preferable. Here we have investigated the potential of micro-discharge optical emission spectroscopy (mu DOES) for the given challenge of on-line quantification of impurity metals in lithium matrices. The technology is based on a micro-plasma, which is directly created inside an aqueous sample without any carrier gas by using electrodes and high voltage pulses. In this study, the impurity elements Na, K, Al, Fe and Zn were simultaneously measured both in lithium carbonate and lithium hydroxide solutions. For this purpose, the lithium concentrations were varied between 0.3 and 2 mg L-1 and those of the contaminants between 0 and 50 mu g L-1. Calibration series and long-term stability measurements were carried out, whereby various parameters such as the plasma discharge energy, signal integration setting and sample electrical conductivity were optimised. Micro-discharge optical emission spectroscopy proved to be useful for the fast and precise main component and trace analysis of saline solutions. A relative standard deviation of 3% was achieved for the lithium concentration in long-term measurements over 9 h. For the trace impurity metals (Na, K, Al, Fe, and Zn) high coefficients of determination (R-2 > 0.99) and limits of detection in the low mu g L-1-region, comparable to ICP-OES, were obtained. Multi-linear regression models were used to correct for cross-element correlations that may occur at increasing lithium concentrations due to ionisation effects. Industrial process samples were measured on-site and the results were validated using laboratory ICP-OES.
引用
收藏
页码:1248 / 1259
页数:13
相关论文
共 50 条
  • [41] Shift endpoint trace selection algorithm and wavelet analysis to detect the endpoint using optical emission spectroscopy
    Sihem Ben Zakour
    Hassen Taleb
    Photonic Sensors, 2016, 6 : 158 - 168
  • [42] Using inductively-coupled plasma optical emission spectroscopy to optimise the analysis of trace elements in gasoline
    Cassap, Matthew
    Spectroscopy Europe, 2010, 22 (05): : 17 - 20
  • [43] Quantification of lithium in LIB electrodes with glow discharge optical emission spectroscopy (GD-OES)
    Takahara, Hikari
    Shikano, Masahiro
    Kobayashi, Hironori
    JOURNAL OF POWER SOURCES, 2013, 244 : 252 - 258
  • [44] Diagnostics of PDP micro-discharge plasmas using infrared laser Thomson scattering system
    Sonoda, Y.
    Akune, A.
    Tomita, K.
    Hassaballa, S.
    Uchino, K.
    Ishii, K.
    Hirano, Y.
    Murakami, Y.
    IDW '07: PROCEEDINGS OF THE 14TH INTERNATIONAL DISPLAY WORKSHOPS, VOLS 1-3, 2007, : 861 - +
  • [45] Production of hard and heat-resistant coatings on aluminium using a plasma micro-discharge
    Gnedenkov, SV
    Khrisanfova, OA
    Zavidnaya, AG
    Sinebrukhov, SL
    Kovryanov, AN
    Scorobogatova, TM
    Gordienko, PS
    SURFACE & COATINGS TECHNOLOGY, 2000, 123 (01): : 24 - 28
  • [46] Measurements of electron temperature and density of a micro-discharge plasma using laser thomson scattering
    Noguchi, Y.
    Matsuoka, A.
    Bowden, M.D.
    Uchino, K.
    Muraoka, K.
    1600, Japan Society of Applied Physics (40):
  • [47] ANALYSIS OF A REACTIVE SPUTTER ION PLATING DISCHARGE FOR TIN DEPOSITION USING OPTICAL-EMISSION SPECTROSCOPY
    RICARD, A
    MICHEL, H
    JACQUOT, P
    GANTOIS, M
    THIN SOLID FILMS, 1985, 124 (01) : 67 - 73
  • [48] Study of dc micro-discharge arrays made in silicon using CMOS compatible technology
    Kulsreshath, M. K.
    Schwaederle, L.
    Overzet, L. J.
    Lefaucheux, P.
    Ladroue, J.
    Tillocher, T.
    Aubry, O.
    Woytasik, M.
    Schelcher, G.
    Dussart, R.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2012, 45 (28)
  • [49] ANALYSIS OF ATMOSPHERIC PARTICULATES FOR TRACE-ELEMENTS BY OPTICAL EMISSION-SPECTROSCOPY
    SCOTT, DR
    LOSEKE, WA
    HOLBOKE, LE
    THOMPSON, RJ
    APPLIED SPECTROSCOPY, 1976, 30 (04) : 392 - 405
  • [50] TRACE-ELEMENT ANALYSIS BY ION INDUCED X-RAY-EMISSION SPECTROSCOPY
    RAITH, B
    ROTH, M
    GOLLNER, K
    GONSIOR, B
    OSTERMANN, H
    UHLHORN, CD
    NUCLEAR INSTRUMENTS & METHODS, 1977, 142 (1-2): : 39 - 44