Capacity analysis of reinforced concrete and composite column on a 7 floor building

被引:0
|
作者
Widayanto, E. [1 ]
Nurtjahjaningtyas, I. [1 ]
Faizeh, S. [1 ]
机构
[1] Univ Jember, Dept Civil Engn, Jember, Indonesia
来源
REVISTA INGENIERIA DE CONSTRUCCION | 2023年 / 38卷 / 01期
关键词
Nominal capacity; reinforced concrete column; composite column; BEHAVIOR;
D O I
10.7764/RIC.00048.21
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To design columns with reinforced concrete material is often used in building construction so that reinforced concrete has several advantages, it is the availability of material, but require a large dimension in holding high capacity. To reduce the dimensions of the column structure can be designed with a composite structure. In this study, an analysis will be carried out to determine the difference in dimensions that can be provided by reinforced concrete columns and composite columns holding an equivalent nominal capacity. This analysis was carried out in a case study of the planning of a 7-story lecture building. The initial design of the column applied is a reinforced concrete column which will then be redesigned with a composite structure using a WF steel profile. Based on the results of the research analysis shows that in holding the nominal capacity equivalent, the dimensions of the composite column used are smaller than the reinforced concrete column. In addition, the volume requirement of the material is also lower, this indicates that the composite column is good enough to be applied in building planning.
引用
收藏
页码:11 / 20
页数:10
相关论文
共 50 条
  • [41] Finite Element Analysis on Circular Steel Tube Composite Column Filled with Steel Reinforced Concrete
    Xu, Yafeng
    Yang, Xu
    Wang, Xin
    Bai, Shouyan
    PROGRESS IN STRUCTURE, PTS 1-4, 2012, 166-169 : 318 - +
  • [42] Experimental Study on Thermal Conductivity of Concrete for Building Reinforced Concrete Composite Wall
    Lu, Meijun
    Yang, Su
    Feng, Xuezhen
    Zhao, Shunbo
    CIVIL ENGINEERING, ARCHITECTURE AND SUSTAINABLE INFRASTRUCTURE II, PTS 1 AND 2, 2013, 438-439 : 329 - 332
  • [43] The shear bearing capacity analysis of circular steel tube composite column filled with steel reinforced concrete under different shear span ratios
    School of Civil Engineering, Shenyang Jianzhu University, Shenyang, Liaoning 110168, China
    Yang, X. (syjzdxyx@yahoo.com.cn), 1600, Tsinghua University (30):
  • [44] Load Testing of Floor Slabs in a Full-scale Reinforced Concrete Building
    Scott, R. H.
    Gilbert, S. G.
    Moss, R. M.
    STRAIN, 2002, 38 (02) : 47 - 54
  • [45] Seismic performance of reinforced concrete eccentric beam-column connections with floor slabs
    Shin, MS
    LaFave, JM
    ACI STRUCTURAL JOURNAL, 2004, 101 (03) : 403 - 412
  • [46] Hysteretic behavior of composite beam-reinforced concrete column frame
    Lu, Xiaofeng
    Zhu, Zhiyu
    Wang, Kun
    Yang, Dongdong
    Zhu, Yanzhu
    Dai, Changming
    RESULTS IN ENGINEERING, 2024, 23
  • [47] BOND CAPACITY OF STEEL REINFORCED CONCRETE COMPOSITE SHORT COLUMNS
    Zhao, Gen-Tian
    PROCEEDINGS OF THE ELEVENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOL I AND II, 2010, : 408 - 413
  • [48] Flexural Capacity of UHPC Reinforced Ordinary Concrete Composite Beam
    Luo M.
    Lin P.
    Yang Z.
    Zhongguo Tiedao Kexue/China Railway Science, 2021, 42 (05): : 21 - 29
  • [49] CYCLIC BEHAVIOR OF COMPOSITE COLUMN-REINFORCED CONCRETE BEAM JOINTS
    Sermet, Fethi
    Ercan, Emre
    Hokelekli, Emin
    Arisoy, Bengi
    SIGMA JOURNAL OF ENGINEERING AND NATURAL SCIENCES-SIGMA MUHENDISLIK VE FEN BILIMLERI DERGISI, 2020, 38 (03): : 1427 - 1445