Accuracy of integration of dental cast and cephalograms compared with cone-beam computed tomography: a comparative study

被引:1
|
作者
Dai, Fanfan [1 ,3 ,4 ,5 ]
Chen, Si [2 ,3 ,4 ,5 ]
Feng, Tingting [6 ]
Lu, Wenhsuan [2 ,3 ,4 ,5 ]
Chen, Gui [2 ,3 ,4 ,5 ]
Jiang, Jiuhui [2 ,3 ,4 ,5 ]
Jiang, Ruoping [2 ,3 ,4 ,5 ]
Lin, Jiuxiang [2 ,3 ,4 ,5 ,7 ]
Han, Bing [2 ,3 ,4 ,5 ,7 ]
Xu, Tianmin [2 ,3 ,4 ,5 ]
机构
[1] Peking Univ, Clin Div 2, Sch & Hosp Stomatol, Beijing, Peoples R China
[2] Peking Univ, Dept Orthodont, Sch & Hosp Stomatol, Beijing, Peoples R China
[3] Natl Clin Res Ctr Oral Dis, Beijing, Peoples R China
[4] Natl Engn Lab Digital & Mat Technol Stomatol, Beijing, Peoples R China
[5] Beijing Key Lab Digital Stomatol Beijing China, Beijing, Peoples R China
[6] Tongji Univ, Dept Orthodont, Affiliated Stomatol Hosp, Shanghai, Peoples R China
[7] Peking Univ, Craniofacial Growth & Dev Ctr, Beijing, Peoples R China
基金
对外科技合作项目(国际科技项目); 北京市自然科学基金;
关键词
Orthodontic; Dental cast; Cephalograms; Cone-beam computed tomography; Registration; Three dimensional; PALATAL RUGAE; SUPERIMPOSITION; IMPLANT; CHILDREN; SKELETAL; ERUPTION; GROWTH; MOLARS; MODEL;
D O I
10.1007/s10266-022-00732-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study proposes a method that integrates maxillary dental cast and cephalograms and evaluates its accuracy compared with cone-beam computed tomography (CBCT) scans. The study sample comprised 20 adult patients with records of dental casts, cephalograms, and craniofacial CBCT scans. The maxillary dental cast was integrated with lateral and frontal cephalograms based on best-fit registration of palatal and dental outline curves from dental cast with cephalogram tracings. Linear measurement was conducted to assess the intra- and inter-examiner reproducibility of the proposed integration method using intraclass correlation coefficients; linear and angular measurements were conducted to assess its accuracy with CBCT scans as a standard reference. Paired t test, one sample t test, and mean +/- standard deviation of the absolute value of difference were used to compare the integrated images and CBCT. The integration method showed good intra- and inter-examiner reproducibility (intraclass correlation coefficients > 0.98). The differences in linear and angular measurements between the integrated images and CBCT were not statistically significant but with a large deviation. When absolute value of difference was computed, the linear distance error was 0.51 +/- 0.34 mm, the tooth point coordinate errors in X, Y and Z axes were 0.22 +/- 0.22, 0.38 +/- 0.32 and 0.21 +/- 0.21 mm, respectively; the angular error in pitch, roll and yaw of the dental cast was 0.82 +/- 0.51, 0.92 +/- 0.59 and 0.80 +/- 0.41 degree, respectively. The proposed method for integration of dental cast and cephalograms showed good reproducibility and acceptable accuracy compared with CBCT. It could be helpful for researchers to study three-dimensional tooth growth changes using the existing craniofacial growth data especially cephalograms.
引用
收藏
页码:238 / 247
页数:10
相关论文
共 50 条
  • [41] MONTE CARLO DOSE ASSESSMENT IN DENTAL CONE-BEAM COMPUTED TOMOGRAPHY
    Kim, Jinwoo
    Jeon, Hosang
    Kim, Ho Kyung
    RADIATION PROTECTION DOSIMETRY, 2021, 193 (3-4) : 190 - 199
  • [42] Accuracy of cone-beam computed tomography in imaging the components of the periodontal phenotype
    Schulze, Ralf
    Couso-Queiruga, Emilio
    Katsaros, Christos
    PERIODONTOLOGY 2000, 2024,
  • [43] Zygomaticofacial foramen location accuracy and reliability in cone-beam computed tomography
    del Neri, Nathalia Bigelli
    Araujo-Pires, Ana Claudia
    Andreo, Jesus Carlos
    Fisher Rubira-Bullen, Izabel Regina
    Ferreira Junior, Osny
    ACTA ODONTOLOGICA SCANDINAVICA, 2014, 72 (02) : 157 - 160
  • [44] Cone-Beam Computed Tomography in Orthodontics
    Abdelkarim, Ahmad
    DENTISTRY JOURNAL, 2019, 7 (03)
  • [45] ACCURACY AND DOSE OF A CONE-BEAM COMPUTED TOMOGRAPHY FOR STEREOTACTIC RADIOSURGERY SETUP
    Sancho, I.
    Modolell, I.
    Ferrer, F.
    Lizuain, M. C.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S422 - S422
  • [46] Automated landmark identification on cone-beam computed tomography: Accuracy and reliability
    Ghowsi, Ali
    Hatcher, David
    Suh, Heeyeon
    Wile, David
    Castro, Wesley
    Krueger, Jan
    Park, Joorok
    Oh, Heesoo
    ANGLE ORTHODONTIST, 2022, 92 (05) : 642 - 654
  • [47] Method of visualisation influences accuracy of measurements in cone-beam computed tomography
    Patcas, Raphael
    Angst, Christine
    Kellenberger, Christian J.
    Schaetzle, Marc A.
    Ullrich, Oliver
    Markic, Goran
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2015, 43 (07) : 1277 - 1283
  • [48] Accuracy and reliability of cone-beam computed tomography for airway volume analysis
    Ghoneima, Ahmed
    Kula, Katherine
    EUROPEAN JOURNAL OF ORTHODONTICS, 2013, 35 (02) : 256 - 261
  • [49] Accuracy of cone-beam computed tomography in predicting the diameter of unerupted teeth
    Nguyen, Emerald
    Boychuk, Darrell
    Orellana, Maria
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (02) : e59 - e66
  • [50] Accuracy and feasibility of cone-beam computed tomography for stereotactic radiosurgery setup
    Chang, Jenghwa
    Yenice, Kamil M.
    Narayana, Ashwatha
    Gutin, Philip H.
    MEDICAL PHYSICS, 2007, 34 (06) : 2077 - 2084