Accuracy of integration of dental cast and cephalograms compared with cone-beam computed tomography: a comparative study

被引:1
|
作者
Dai, Fanfan [1 ,3 ,4 ,5 ]
Chen, Si [2 ,3 ,4 ,5 ]
Feng, Tingting [6 ]
Lu, Wenhsuan [2 ,3 ,4 ,5 ]
Chen, Gui [2 ,3 ,4 ,5 ]
Jiang, Jiuhui [2 ,3 ,4 ,5 ]
Jiang, Ruoping [2 ,3 ,4 ,5 ]
Lin, Jiuxiang [2 ,3 ,4 ,5 ,7 ]
Han, Bing [2 ,3 ,4 ,5 ,7 ]
Xu, Tianmin [2 ,3 ,4 ,5 ]
机构
[1] Peking Univ, Clin Div 2, Sch & Hosp Stomatol, Beijing, Peoples R China
[2] Peking Univ, Dept Orthodont, Sch & Hosp Stomatol, Beijing, Peoples R China
[3] Natl Clin Res Ctr Oral Dis, Beijing, Peoples R China
[4] Natl Engn Lab Digital & Mat Technol Stomatol, Beijing, Peoples R China
[5] Beijing Key Lab Digital Stomatol Beijing China, Beijing, Peoples R China
[6] Tongji Univ, Dept Orthodont, Affiliated Stomatol Hosp, Shanghai, Peoples R China
[7] Peking Univ, Craniofacial Growth & Dev Ctr, Beijing, Peoples R China
基金
对外科技合作项目(国际科技项目); 北京市自然科学基金;
关键词
Orthodontic; Dental cast; Cephalograms; Cone-beam computed tomography; Registration; Three dimensional; PALATAL RUGAE; SUPERIMPOSITION; IMPLANT; CHILDREN; SKELETAL; ERUPTION; GROWTH; MOLARS; MODEL;
D O I
10.1007/s10266-022-00732-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study proposes a method that integrates maxillary dental cast and cephalograms and evaluates its accuracy compared with cone-beam computed tomography (CBCT) scans. The study sample comprised 20 adult patients with records of dental casts, cephalograms, and craniofacial CBCT scans. The maxillary dental cast was integrated with lateral and frontal cephalograms based on best-fit registration of palatal and dental outline curves from dental cast with cephalogram tracings. Linear measurement was conducted to assess the intra- and inter-examiner reproducibility of the proposed integration method using intraclass correlation coefficients; linear and angular measurements were conducted to assess its accuracy with CBCT scans as a standard reference. Paired t test, one sample t test, and mean +/- standard deviation of the absolute value of difference were used to compare the integrated images and CBCT. The integration method showed good intra- and inter-examiner reproducibility (intraclass correlation coefficients > 0.98). The differences in linear and angular measurements between the integrated images and CBCT were not statistically significant but with a large deviation. When absolute value of difference was computed, the linear distance error was 0.51 +/- 0.34 mm, the tooth point coordinate errors in X, Y and Z axes were 0.22 +/- 0.22, 0.38 +/- 0.32 and 0.21 +/- 0.21 mm, respectively; the angular error in pitch, roll and yaw of the dental cast was 0.82 +/- 0.51, 0.92 +/- 0.59 and 0.80 +/- 0.41 degree, respectively. The proposed method for integration of dental cast and cephalograms showed good reproducibility and acceptable accuracy compared with CBCT. It could be helpful for researchers to study three-dimensional tooth growth changes using the existing craniofacial growth data especially cephalograms.
引用
收藏
页码:238 / 247
页数:10
相关论文
共 50 条
  • [1] Reliability and accuracy of cone-beam computed tomography dental measurements
    Baumgaertel, Sebastian
    Palomo, J. Martin
    Palomo, Leena
    Hans, Mark G.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) : 19 - 25
  • [2] Comparative analysis of upper airway volume with lateral cephalograms and cone-beam computed tomography
    Feng, Xin
    Li, Gang
    Qu, Zhenyu
    Liu, Lin
    Nasstrom, Karin
    Shi, Xie-Qi
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2015, 147 (02) : 197 - 204
  • [3] Accuracy and Landmark Error Calculation Using Cone-Beam Computed Tomography-Generated Cephalograms
    Grauer, Dan
    Cevidanes, Lucia S. H.
    Styner, Martin A.
    Heulfe, Inam
    Harmon, Eric T.
    Zhu, Hongtu
    Proffit, William R.
    ANGLE ORTHODONTIST, 2010, 80 (02) : 286 - 294
  • [4] Diagnostic accuracy of lateral cephalograms and cone-beam computed tomography for the assessment of sella turcica bridging
    Acevedo, Ashley Marie
    Lagravere-Vich, Manuel
    Al-Jewair, Thikriat
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2021, 160 (02) : 231 - 239
  • [6] Accuracy of cone-beam computed tomography for syndesmosis injury diagnosis compared to conventional computed tomography
    Hamard, Marion
    Neroladaki, Angeliki
    Bagetakos, Ilias
    Dubois-Ferriere, Victor
    Montet, Xavier
    Boudabbous, Sana
    FOOT AND ANKLE SURGERY, 2020, 26 (04) : 265 - 272
  • [7] Comparative study of jaws with multislice computed tomography and cone-beam computed tomography
    Carrafiello, G.
    Dizonno, M.
    Colli, V.
    Strocchi, S.
    Taubert, S. Pozzi
    Leonardi, A.
    Giorgianni, A.
    Barresi, M.
    Macchi, A.
    Bracchi, E.
    Conte, L.
    Fugazzola, C.
    RADIOLOGIA MEDICA, 2010, 115 (04): : 600 - 611
  • [8] Comparison between conventional and cone-beam computed tomography-generated cephalograms
    Cattaneo, Paolo M.
    Bloch, Christian Borgkvist
    Calmar, Dorte
    Hjortshoj, Mette
    Melsen, Birte
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (06) : 798 - 802
  • [9] Landmark identification errors on cone-beam computed tomography-derived cephalograms and conventional digital cephalograms
    Chang, Zwei-Chieng
    Hu, Fu-Chang
    Lai, Eddie
    Yao, Chung-Chen
    Chen, Mu-Hsiung
    Chen, Yi-Jane
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (06) : E289 - E297
  • [10] Dental long axes using digital dental models compared to cone-beam computed tomography
    Cong, Amalia
    Massaro, Camila
    de Oliveira Ruellas, Antonio Carlos
    Barkley, Mary
    Yatabe, Marilia
    Bianchi, Jonas
    Ioshida, Marcos
    Alvarez, Maria Antonia
    Fernando Aristizabal, Juan
    Rey, Diego
    Cevidanes, Lucia
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2022, 25 (01) : 64 - 72