The Light-Dosimeter: A new device to help advance research on the non-visual responses to light

被引:15
|
作者
Stampfli, J. R. [1 ]
Schrader, B. [1 ,9 ]
di Battista, C. [1 ]
Haefliger, R. [1 ]
Schalli, O. [1 ]
Wichmann, G. [1 ]
Zumbuhl, C. [1 ]
Blattner, P. [2 ]
Cajochen, C. [3 ,4 ]
Lazar, R. [3 ,4 ]
Spitschan, M. [4 ,5 ,6 ,7 ,8 ]
机构
[1] Lucerne Sch Engn & Architecture, Horw, Switzerland
[2] Fed Inst Metrol METAS, Bern, Switzerland
[3] Psychiat Hosp Univ Basel UPK, Ctr Chronobiol, Basel, Switzerland
[4] Univ Basel, Res Platform Mol & Cognit Neurosci, Basel, Switzerland
[5] Univ Oxford, Dept Expt Psychol, Oxford, England
[6] Max Planck Inst Biol Cybernet, Translat Sensory & Circadian Neurosci, Tubingen, Germany
[7] Tech Univ Munich, TUM Dept Sport & Hlth Sci TUM SG, Munich, Germany
[8] Tech Univ Munich, TUM Inst Adv Study TUM IAS, Garching, Germany
[9] Lucerne Sch Engn & Architecture, Technikumstr 21, CH-6048 Horw, Switzerland
基金
英国惠康基金; 欧盟地平线“2020”;
关键词
RETINAL GANGLION-CELLS; EXPOSURE; PERFORMANCE; MELANOPSIN; SLEEP;
D O I
10.1177/14771535221147140
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This article describes the development of a device to investigate the non-visual responses to light: The Light-Dosimeter (lido). Its multidisciplinary team followed a user-centred approach throughout the project, that is, their design decisions focused on researchers' and participants' needs. Together with custom-made mountings and the software Lido Studio, the lidos provide researchers with a holistic solution to record participants' light exposure in the near-corneal plane in laboratory settings and under real-world conditions. Validation measurements with commercial equipment were deemed satisfying, as was the combining with data from other devices. The handling of the lidos and mountings and the use of the software Lido Studio during the trial period by various researchers and participants were successful. Despite some limitations, the lidos can help advance research on the non-visual responses to light over the coming years.
引用
收藏
页码:474 / 486
页数:13
相关论文
共 50 条
  • [21] CIE Statement on Non-Visual Effects of Light RECOMMENDING PROPER LIGHT AT THE PROPER TIME
    Zwick, Peter
    LIGHT & ENGINEERING, 2015, 23 (04): : 4 - 5
  • [22] MODELLING NON-VISUAL RESPONSES TO LIGHT: UNIFYING SPECTRAL AND TEMPORAL CHARACTERISTICS IN A SINGLE MODEL STRUCTURE
    Amundadottir, M. L.
    St Hilaire, M. A.
    Lockley, S. W.
    Andersen, M.
    PROCEEDINGS OF THE CIE CENTENARY CONFERENCE TOWARDS A NEW CENTURY OF LIGHT, 2013, : 101 - 110
  • [23] Correlated color temperature and light intensity: Complementary features in non-visual light field
    Arguelles-Prieto, Raquel
    Antonio Madrid, Juan
    Angeles Rol, Maria
    Bonmati-Carrion, Maria Angeles
    PLOS ONE, 2021, 16 (07):
  • [24] Non-visual effects of indoor light environment on humans: A review
    Xiao, Hui
    Cai, Huiling
    Li, Xuefeng
    PHYSIOLOGY & BEHAVIOR, 2021, 228
  • [25] Beyond Blue: The Non-Visual Effects of Light and Colour in Architecture
    Sadar, John Stanislav
    ARCHITECTURAL THEORY REVIEW, 2014, 19 (02) : 174 - 192
  • [26] Ambulant recording of light for vision and non-visual biological effects
    Hubalek, S.
    Zoschg, D.
    Schierz, C.
    LIGHTING RESEARCH & TECHNOLOGY, 2006, 38 (04) : 314 - 324
  • [27] APPLICATION STUDIES ON NON-VISUAL EFFECTS OF LIGHT WITH TRADITIONAL AND SOLID STATE LIGHT SOURCES
    Wojtysiak, A.
    Lang, D.
    PROCEEDINGS OF THE CIE CENTENARY CONFERENCE TOWARDS A NEW CENTURY OF LIGHT, 2013, : 91 - 94
  • [29] Proposal for the standard evaluation procedure for non-visual action of light
    Kozakov R.
    Schoepp H.
    Journal of Light and Visual Environment, 2011, 35 (03): : 274 - 277
  • [30] NON-VISUAL LIGHT RESPONSIVENESS IN PIGEON - DEVELOPMENTAL AND COMPARATIVE CONSIDERATIONS
    HEATON, MB
    HARTH, MS
    JOURNAL OF EXPERIMENTAL ZOOLOGY, 1974, 188 (03): : 251 - 263