Electrochemical Sensing Performances of Screen-Printed Graphene-Carbon-Paste Electrodes on Digital Microfluidic Chips

被引:1
|
作者
Ugsornrat, Kessararat [1 ]
Saenkhamai, Anan [1 ]
Chantaraklud, Apichaya [1 ]
Pasakon, Patiya [2 ]
Karuwan, Chanpen [2 ]
Sriprachuabwong, Chakrit [2 ]
Atthi, Nithi [3 ]
Wisitsoraat, Anurat [2 ]
Tuantranont, Adisorn [2 ]
机构
[1] King Mongkuts Univ Technol North Bangkok, Dept Ind Phys & Med Instrumentat, Bangkok 10800, Thailand
[2] Natl Sci & Technol Dev Agcy, Graphene & Printed Elect Res Div, Pathum Thani 12120, Thailand
[3] Natl Sci & Technol Dev Agcy NSTDA, Natl Elect & Comp Technol Ctr NECTEC, Thai Microelect Ctr TMEC, Chacheongsao 24000, Thailand
关键词
Digital microfluidic; electrochemical sensing; screen-printed graphene electrodes (SPGEs); ELECTROWETTING-BASED ACTUATION; ON-A-CHIP; LIQUID DROPLETS; SENSOR; LAB;
D O I
10.1109/JSEN.2023.3327827
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this research, screen-printed graphene electrodes (SPGEs) were fabricated on a single-plate electrowetting-on-dielectric (EWOD) digital microfluidic chip. The chip contained T-junction EWOD structures for merging buffer reagent and analyzed droplets and the electrochemical sensor based on SPGEs at the end of T-junction. The EWOD structures consisted of silver EWOD electrodes, a polydimethylsiloxane dielectric layer, and Teflon1AF hydrophobic layers. The electrochemical sensor comprised a working SPGE, a counter SPGE, and a screen-printed silver/silver chloride reference electrode. Both EWOD and electrochemical electrodes were fabricated by a screen-printing technique. The digital microfluidic chip with the SPGE sensor was applied to mix and analyze three biochemical reagents, including potassium hexacyanoferrate ( K-4 Fe(CN)(6)) , nicotinamide adenine dinucleotide (NADH), and hydrogen peroxide ( H2O2) . The electrochemical measurements were conducted using cyclic voltammetry over the concentration ranges of 10-500 mu M , 10-500 mu M , and 1000-7500 mu M for K-4 Fe(CN)(6), NADH, and H2O2 , respectively. The results showed that the detection performances, including sensitivity and detection limit of SPGE sensor on the EWOD chip, were considerably better than those of screen-printed carbon paste electrodes (SCPEs).
引用
下载
收藏
页码:28613 / 28625
页数:13
相关论文
共 50 条
  • [11] Screen-printed graphene-based electrochemical sensors for a microfluidic device
    Karuwan, C.
    Wisitsoraat, A.
    Chaisuwan, P.
    Nacapricha, D.
    Tuantranont, A.
    ANALYTICAL METHODS, 2017, 9 (24) : 3689 - 3695
  • [12] Glucose sensing on screen-printed electrochemical electrodes based on porous graphene aerogel @prussian blue
    Tao Hu
    Di Wang
    Jian Xu
    Ke Chen
    Xiao Li
    Hong Yi
    Zhonghua Ni
    Biomedical Microdevices, 2022, 24
  • [13] Glucose sensing on screen-printed electrochemical electrodes based on porous graphene aerogel @prussian blue
    Hu, Tao
    Wang, Di
    Xu, Jian
    Chen, Ke
    Li, Xiao
    Yi, Hong
    Ni, Zhonghua
    BIOMEDICAL MICRODEVICES, 2022, 24 (01)
  • [14] Facile Fabrication of Screen-Printed Carbon Electrodes for Electrochemical Sensors
    Sarmphim, P.
    Teeparuksapun, K.
    Wunsri, S.
    Sorngodchagorn, S.
    Duangsiri, W.
    Tapparak, P.
    Sirisathitkul, C.
    INTERNATIONAL JOURNAL OF NANOELECTRONICS AND MATERIALS, 2021, 14 (01): : 1 - 10
  • [15] Electrochemical Characterization of Ordered Mesoporous Carbon Screen-Printed Electrodes
    Martin-Yerga, Daniel
    Costa Rama, Estefania
    Costa-Garcia, Agustin
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2016, 163 (05) : B176 - B179
  • [16] Electrochemical Behavior of Screen-Printed Carbon Electrodes as Transducers in Biosensors
    Dorledo de Faria, Ricardo Adriano
    Douaud, Alexandre
    Soares, Renata Braga
    Dias Heneine, Luiz Guilherme
    Matencio, Tulio
    Cunha Lins, Vanessa de Freitas
    Messaddeq, Younes
    CORROSION, 2020, 76 (06) : 553 - 561
  • [17] Multiphysics Modeling of the Electrochemical Response of Screen-Printed Electrodes for Sensing Applications
    Bonaldo, Stefano
    Franchin, Lara
    Rosati, Giulio
    Merkoci, Arben
    Paccagnella, Alessandro
    IEEE SENSORS JOURNAL, 2024, 24 (15) : 23960 - 23967
  • [18] Screen-printed microfluidic device for electrochemical immunoassay
    Dong, Hua
    Li, Chang-Ming
    Zhang, Yi-Fan
    Cao, Xiao-Dong
    Gan, Ye
    LAB ON A CHIP, 2007, 7 (12) : 1752 - 1758
  • [19] A disposable screen printed graphene-carbon paste electrode and its application in electrochemical sensing
    Karuwan, Chanpen
    Wisitsoraat, Anurat
    Phokharatkul, Ditsayut
    Sriprachuabwong, Chakrit
    Lomas, Tanom
    Nacapricha, Duangjai
    Tuantranont, Adisorn
    RSC ADVANCES, 2013, 3 (48): : 25792 - 25799