Assessment of Optimal Suture Knot-Tying Force Range for Pancreaticogastrostomy Anastomosis in Pancreaticoduodenectomy

被引:0
|
作者
Poonguzhali, S. [1 ]
Dinesh, S. [1 ]
Devakumar, M. Satish [2 ]
Jeswanth, S. [2 ]
机构
[1] Anna Univ, Chennai 600025, India
[2] Stanley Med Coll, Chennai 600001, India
关键词
Suture tension; Whipple's procedure; Anastomosis; Pancreatic leak; Postoperative care; Postoperative pancreatic fistula; POSTOPERATIVE PANCREATIC FISTULA; SIMULATION; ETIOLOGY; WHIPPLE; DUCT;
D O I
10.1007/s12262-023-03956-0
中图分类号
R61 [外科手术学];
学科分类号
摘要
One of the parameters related to the result of Whipple's procedure or Pancreaticoduodenectomy (PD) is the suture knot-tying force during pancreaticogastrostomy anastomosis. We hypothesize that an imbalanced suture force during surgical anastomosis can result in postoperative problems such as postoperative pancreatic fistula (POPF). The consequences are potentially fatal, discouraging the surgeon from conducting such complex surgery. The purpose of this study was to find the best suture knot-tying force for pancreaticogastrostomy anastomosis in PD and to determine the best force range for suture knot-tying to prevent pancreatic leaks. In 36 patients, the designed suture force measurement device (SFD) was clinically evaluated. The patients were monitored postoperatively for any complications, and the suture knot-tying force data were used for analysis. The optimal force range and surgical success had a significant positive connection (P < 0.01). The best suture knot-tying force to avoid pancreatic leak following PD was (3.39 SD0.71) for the soft pancreas, (4.38 SD0.71) for the firm pancreas, and (7.70 SD0.62) for the hard pancreas. Suture knot strength is a significant factor in determining the surgical outcome. A suture knot tied at the optimal force range speeds up healing and avoids other postoperative problems. Suture knots performed beyond the optimal range, on the other hand, were observed with POPF. The study to prevent pancreatic leakage after PD revealed the best suture force range for pancreaticogastrostomy anastomosis. The trial was approved by the Institutional Ethics Committee of Government Stanley Medical College. The Institutional Ethics Committee is reregistered with the Central Drugs Standards Control Organization, ethics committee division with register number ECR/131/Inst/TN/2013/RR19.
引用
收藏
页码:748 / 755
页数:8
相关论文
共 45 条
  • [41] Arthroscopic Rotator Cuff Repair Using Modified Mason-Allen Medial Row Stitch Knotless Versus Knot-Tying Suture Bridge Technique
    Rhee, Yong Girl
    Cho, Nam Su
    Parke, Chong Suck
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2012, 40 (11): : 2440 - 2447
  • [42] Repair Integrity and Functional Outcomes Between Knot-Tying and Knotless Suture-Bridge Arthroscopic Rotator Cuff Repair: A Prospective Randomized Clinical Trial
    Sahin, Koray
    Senturk, Fatih
    Ersin, Mehmet
    Arzu, Ufuk
    Chodza, Mechmet
    Ersen, Ali
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (04)
  • [43] Assessment of time to completion, number of errors, and knot-holding capacity of square knots and Aberdeen knots tied by veterinary students and student perceptions of knot security and knot-tying difficulty
    Upchurch, David A.
    Wang, Yuheng
    Chen, Sheng
    Roccabianca, Sara
    Roush, James K.
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2020, 256 (02): : 230 - 238
  • [44] Arthroscopic rotator cuff repair using modified Mason-Allen medial row stitch: knotless versus knot-tying suture bridge technique (vol 40, pg 2240, 2012)
    Rhee, Y. G.
    Cho, N. S.
    Parke, C. S.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2013, 41 (08): : NP41 - NP41
  • [45] The reliability, sensitivity, and specificity of Global Evaluative Assessment of Robotic Skills (GEARS) and binary scoring metrics of robotic suturing and knot tying skills in a Vesico Urethral Anastomosis (VUA) task
    Gallagher, A.
    De Groote, R.
    Puliatti, S.
    Mazzone, E.
    Amato, M.
    Rosiello, G.
    Paludo, A.
    Mottrie, A.
    EUROPEAN UROLOGY, 2021, 79 : S1366 - S1366