Long-Term Assessment of Thin-Strut BioMime Coronary Stent System in Real-World Population at Single-Center: A Retrospective Observational Study

被引:0
|
作者
Palleda, Girish Meennahalli [1 ]
Gupta, Mohit [1 ]
Bansal, Ankit [1 ]
Batra, Vishal [1 ]
Tyagi, Sanjay [1 ]
Kunal, Shekhar [1 ]
机构
[1] Gobind Ballabh Pant Hosp, Dept Cardiol, New Delhi, India
关键词
Biodegradable polymers; BioMime stent; Coronary ar-tery disease; Long-term; Major adverse cardiovascular events; Percu-taneous coronary intervention; Stent thrombosis; Thinner-strut; SIROLIMUS-ELUTING STENT; BARE-METAL STENTS; BIODEGRADABLE-POLYMER; CLINICAL-OUTCOMES; 2ND-GENERATION; METAANALYSIS; TRIALS; EFFICACY; SAFETY;
D O I
10.14740/cr1515
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The short-term clinical outcomes of first-generation thicker-strut durable polymer-based drug-eluting stents (DES) have been widely examined. However, there is a scarcity on qualitative research on the long-term usage of DES that evaluated the thinner strut biodegradable stents for coronary artery disease. Hence, we sought to investigate the long-term safety and performance of thinner strut bio-degradable polymer-based BioMime sirolimus-eluting coronary stent system in real-world patients with symptomatic ischemic heart disease.Methods: This was a retrospective, observational, single-center, post-marketing clinical follow-up study. The primary endpoints were the incidence of major adverse cardiac events (MACEs), defined as a composite of cardiac death, myocardial infarction (MI) attributed to target vessel revascularization (TVR), and target lesion revascu-larization (TLR) at 1-, 2-, 3-and 4-year follow-ups. The secondary endpoints were cardiac death, MI, TLR, TVR, device and procedural success rates, and stent thrombosis (ST).Results: In all, 1,188 consecutive patients were enrolled, and 1,333 (1,257 de novo and 76 in-stent restenotic lesions) out of 1,565 lesions were treated with the study device. The mean age of patients was 53.26 +/- 10.31 years and 86.2% were male. The quantitative coronary angio-graphic derived mean lesion length and diameter were 29.62 +/- 9.62 mm and 3.01 +/- 0.29 mm, respectively. The average length and diameter of the study device implanted were 30.89 +/- 6.31 mm and 3.17 +/- 0.25 mm, respectively. The cumulative incidence of MACE at 1, 2, 3, and 4 years was 0.61%, 1.47%, 2.08%, and 3.40%, respectively, and cumulative deaths due to cardiac causes were 0.61%, 1.13%, 1.22%, and 1.83%, respectively. There were no cases of TLR or TVR at 1-year follow-up. The cumulative rate of TLR at 2, 3, and 4 years was 0.35%, 0.87%, and 1.57%, respectively, while that of TVR was 0.61%, 1.47%, and 2.35%, respectively. Three (0.3%) incidences of probable ST occurred during the 6-month follow-up; no new cases were reported further. In sub-group analysis, MACEs were comparable across the long-and short-length stent groups through 4-year follow-up.Conclusions: This long-term study demonstrates the safety and per-formance of the ultra-thin BioMime sirolimus-eluting stent with satis-factory clinical outcomes in patients with symptomatic ischemic heart disease in real-world scenario.
引用
收藏
页码:360 / 369
页数:10
相关论文
共 50 条
  • [31] Long-term mortality rates in pediatric hydrocephalus—a retrospective single-center study
    Matthias Gmeiner
    Helga Wagner
    Christoph Zacherl
    Petra Polanski
    Christian Auer
    Willem J.R. van Ouwerkerk
    Kurt Holl
    Child's Nervous System, 2017, 33 : 101 - 109
  • [32] Long-Term Outcomes of Laparoscopic Sleeve Gastrectomy—a Single-Center, Retrospective Study
    Piotr K. Kowalewski
    Robert Olszewski
    Maciej S. Walędziak
    Michał R. Janik
    Andrzej Kwiatkowski
    Natalia Gałązka-Świderek
    Krzysztof Cichoń
    Jakub Brągoszewski
    Krzysztof Paśnik
    Obesity Surgery, 2018, 28 : 130 - 134
  • [33] Myoclonic absence seizures: a single-center long-term longitudinal retrospective study
    Galati, G.
    Ghobert, L.
    Lo Barco, T.
    Detoraki, M.
    Fiorini, E.
    Fontana, E.
    Darra, F.
    Bernardina, B. Dalla
    Cantalupo, G.
    EPILEPSIA, 2022, 63 : 251 - 251
  • [34] Long-Term Hepatitis B Surface Antigen Profile and Seroclearance Following Antiviral Treatment: A Single-Center, Real-World Cohort Study
    Huang, Chih-Wen
    Yang, Chen-Ta
    Su, Pei-Yuan
    Chen, Yang-Yuan
    Huang, Siou-Ping
    Yen, Hsu-Heng
    BIOMEDICINES, 2023, 11 (11)
  • [35] LONG-TERM EFFICACY AND SAFETY OF RISANKIZUMAB: A RETROSPECTIVE, MULTICENTER, REAL-WORLD STUDY
    Kim, Han-Na
    Woo, Bin
    Kim, Young Chan
    Kim, Dai-Hyun
    Son, Sang Wook
    Baek, Yoo Sang
    ACTA DERMATO-VENEREOLOGICA, 2024, 104
  • [36] Efficacy and safety of telitacicept in patients with lupus nephritis: a single-center, real-world retrospective study
    Huang, Xiaolu
    Lin, Fuan
    Chen, Hongpu
    CLINICAL AND EXPERIMENTAL NEPHROLOGY, 2024, 28 (09) : 902 - 909
  • [37] Real-world experience with apremilast for the treatment of psoriasis: Retrospective single-center study in the Canary Islands
    Lukoviek, V.
    Arteaga-Henriquez, M.
    Ramirez-Conchas, J.
    Markthaler, M.
    Pestana-Eliche, M.
    Garcia-Bustinduy, M.
    Guimera-Martin-Neda, F.
    Perez-Robayna, N.
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2019, 81 (04) : AB115 - AB115
  • [38] Effectiveness and safety of vedolizumab for ulcerative colitis: a single-center retrospective real-world study in China
    Huang, Kaituo
    Liu, Jing
    Xia, Wenhao
    Tian, Chuwen
    Yao, Lingya
    Cao, Qian
    Chen, Haotian
    FRONTIERS IN PHARMACOLOGY, 2023, 14
  • [39] Real-world effectiveness and safety of bimekizumab in Japanese patients with psoriasis: A single-center retrospective study
    Hagino, Teppei
    Saeki, Hidehisa
    Fujimoto, Eita
    Kanda, Naoko
    JOURNAL OF DERMATOLOGY, 2024, 51 (05): : 649 - 658
  • [40] Everolimus Eluting Stent in the Real-World Setting-A Single-Center Two-Year Study
    Hyde, Lauren
    Liang, Michael
    Puri, Aniket
    Devlin, Gerry
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 105 (9A): : 13B - 13B