The effect of periprosthetic bone loss on the failure risk of tibial total knee arthroplasty

被引:5
|
作者
Soltanihafshejani, Navid [1 ,3 ]
Bitter, Thom [1 ]
Verdonschot, Nico [1 ,2 ]
Janssen, Dennis [1 ]
机构
[1] Radboud Univ Nijmegen, Inst Hlth Sci, Med Ctr, Orthopaed Res Lab, Nijmegen, Netherlands
[2] Univ Twente, Fac Engn Technol, Lab Biomech Engn, Enschede, Netherlands
[3] Radboud Univ Nijmegen, Radboud Inst Hlth Sci, Med Ctr, Orthopaed Res Lab, 620 Geert Grootepl Zuid 30, NL-6525 GA Nijmegen, Netherlands
关键词
bone mineral density; bone resorption; finite element analysis; medial tibial collapse; total knee arthroplasty; TRABECULAR BONE; PROXIMAL TIBIA; CORTICAL BONE; DENSITY; DAMAGE; REPLACEMENTS; OSTEOARTHRITIS; BEHAVIOR; FRACTURE;
D O I
10.1002/jor.25642
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The effect of long-term periprosthetic bone loss on the process of aseptic loosening of tibial total knee arthroplasty (TKA) is subject to debate. Contradicting studies can be found in literature, reporting either bone resorption or bone formation before failure of the tibial tray. The aim of the current study was to investigate the effects of bone resorption on failure of tibial TKA, by simulating clinical postoperative bone density changes in finite element analysis (FEA) models and FEA models were created of two tibiae representing cases with good and poor initial bone quality which were subjected to a walking configuration and subsequently to a traumatic stumbling load. Bone failure was simulated using a crushable foam model incorporating progressive yielding. Repetitive loading under a level walking load did not result in failure of the periprosthetic bone in neither the good nor poor bone quality tibia at the baseline bone densities. When applying a stumble load, a collapse of the tibial reconstruction was noticed in the poor bone quality model. Incorporating postoperative bone loss led to a significant increase of the failure risk, particularly for the poor bone quality model in which subsidence of the tibial component was substantial. Our results suggest bone loss can lead to an increased risk of a collapse of the tibial component, particularly in case of poor bone quality at the time of surgery. The study also examined the probability of medial or lateral subsidence of the implant and aimed to improve clinical implications. The FEA model simulated plastic deformation of the bone and implant subsidence, with further validation required via mechanical experiments.
引用
收藏
页码:90 / 99
页数:10
相关论文
共 50 条
  • [21] Risk factors for periprosthetic joint infection in total knee arthroplasty
    Lee, Qunn Jid
    Mak, Wai Ping
    Wong, Yiu Chung
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (03) : 282 - 286
  • [22] Revision Total Knee Arthroplasty Causes of failure, bone loss management and outcomes
    Viscopoleanu, George
    Sendrea, Bogdan
    Haritinian, Emil
    REVISTA DE CHIMIE, 2018, 69 (08): : 2225 - 2227
  • [23] Use of structural allograft in revision total knee arthroplasty in knees with severe tibial bone loss
    Engh, Gerard A.
    Ammeen, Deborah J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (12): : 2640 - 2647
  • [24] Do bisphosphonates reduce early micromotion and periprosthetic bone loss in total knee arthroplasty? A review of the evidence
    Calvisi, V.
    Lupparelli, S.
    Padua, R.
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2006, 7 (04) : 201 - 206
  • [25] BONE-GRAFT FOR TIBIAL DEFECTS IN TOTAL KNEE ARTHROPLASTY
    DORR, LD
    RANAWAT, CS
    SCULCO, TA
    MCKASKILL, B
    ORISEK, BS
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1986, (205) : 153 - 165
  • [26] MECHANISMS OF FAILURE OF THE FEMORAL AND TIBIAL COMPONENTS IN TOTAL KNEE ARTHROPLASTY
    WINDSOR, RE
    SCUDERI, GR
    MORAN, MC
    INSALL, JN
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1989, (248) : 15 - 20
  • [27] Approach of tibial bone defects in primary total knee arthroplasty
    Georgeanu, V.
    Predescu, V.
    Atasiei, T.
    Cristea, S.
    2010 ADVANCED TECHNOLOGIES FOR ENHANCING QUALITY OF LIFE (AT-EQUAL), 2010, : 69 - 74
  • [28] Detection of Small Periprosthetic Bone Defects after Total Knee Arthroplasty
    Minoda, Yukihide
    Yoshida, Taku
    Sugimoto, Kazutaka
    Baba, Shinogo
    Ikebuchi, Mitssuhiko
    Nakamura, Hiroaki
    JOURNAL OF ARTHROPLASTY, 2014, 29 (12): : 2280 - 2284
  • [29] Bilateral periprosthetic tibial stress fracture after total knee arthroplasty: A case report
    Ozdemir, Guzelali
    Azboy, Ibrahim
    Yilmaz, Baris
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2016, 24 : 175 - 178
  • [30] Periprosthetic tibial fractures after cementless low contact stress total knee arthroplasty
    Thompson, NW
    McAlinden, MG
    Breslin, E
    Crone, MD
    Kernohan, WG
    Beverland, DE
    JOURNAL OF ARTHROPLASTY, 2001, 16 (08): : 984 - 990