Performance simulation and analysis of a multi-energy complementary energy supply system for a novel BIPVT nearly zero energy building

被引:15
|
作者
Ren, Haibo [1 ]
Quan, Zhenhua [1 ]
Wang, Zhaomeng [1 ]
Wang, Lincheng [1 ]
Jing, Heran [2 ]
Zhao, Yaohua [1 ,2 ]
机构
[1] Beijing Univ Technol, Beijing Key Lab Green Built Environm & Energy Effi, Beijing 100124, Peoples R China
[2] Boyi Energy Technol Dev Co, Zibo 255220, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
Building integrated photovoltaic thermal; Dual heat source heat pump; Dynamic simulation; Energy consumption analysis; Nearly zero energy building; (BIPVT); HEAT; WATER; COLLECTORS;
D O I
10.1016/j.enconman.2023.116879
中图分类号
O414.1 [热力学];
学科分类号
摘要
Building integrated photovoltaic-thermal (BIPVT) technology is an efficient form of solar energy utilization, which realizes self-energy supply and holds good development prospects. In this paper, a novel BIPVT module based on micro heat pipe array and BIPVT near-zero energy building are proposed. A matching multi-energy complementary energy supply system is also proposed for this building. The building and energy supply sys-tem models were built using TRNSYS. The load characteristics of BIPVT buildings were studied by analyzing the heat transfer process of BIPVT components. The energy-saving rate of the building was also calculated using the method of near-zero energy building evaluation index. The accumulated cooling load and heating load of the buildings throughout the year show that those of the BIPVT buildings are 8.6% higher than those of the benchmark building. Comparison of the energy consumption results shows that the annual cumulative energy consumption of the BIPVT building is 32.3% lower compared to the benchmark building's. In addition, 61.2% of the energy required for year-round refrigeration, heating, and electricity can be supplied by this system. The energy consumption index of the BIPVT building is 70.26 kWh / (m2 center dot a). Compared with the benchmark building, the BIPVT building energy saving rate is 76.6% and the building energy efficiency improvement rate is 32.3%.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Research and Application of Multi-energy Complementary Comprehensive Energy Distributed Measurement and Control System
    Wei, Dajun
    Zhang, Yuanpeng
    Li, Junen
    Yuan, Shuai
    Geng, Yujie
    Cheng, Yan
    Yu, Peng
    Wang, Yuejiao
    Teng, Wei
    2020 4TH INTERNATIONAL WORKSHOP ON RENEWABLE ENERGY AND DEVELOPMENT (IWRED 2020), 2020, 510
  • [42] Energy flow process for multi-energy complementary anaerobic fermentation system of agricultural residues
    Yang, Xuemei
    Zhang, Zhiping
    Wang, Yanjin
    Zhang, Huan
    He, Chao
    Zhang, Quanguo
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2019, 40 (04): : 936 - 941
  • [43] Energy flow analysis of the multi-energy energy router
    Li, Shuo
    Li, Zichen
    Li, Pengfei
    Zhang, Yanchi
    Xie, Da
    FOURTH INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION, 2020, 467
  • [44] Comprehensive sustainability assessment and multi-objective optimization of a novel renewable energy driven multi-energy supply system
    Liu, Lintong
    Zhai, Rongrong
    Xu, Yu
    Hu, Yangdi
    Liu, Siyuan
    Yang, Lizhong
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [45] Multi-scenario analysis and collaborative optimization of a novel distributed energy system coupled with hybrid energy storage for a nearly zero-energy community
    Liu, Zhijian
    Guo, Jiacheng
    Li, Ying
    Wu, Di
    Zhang, Shicong
    Yang, Xinyan
    Ge, Hua
    Cai, Zeping
    JOURNAL OF ENERGY STORAGE, 2021, 41
  • [46] Multi-energy synergistic planning of distributed energy supply system: Wind-solar-hydrogen coupling energy supply
    Li, Ling-Ling
    Zhang, Zi-Yu
    Sethanan, Kanchana
    Tseng, Ming-Lang
    Renewable Energy, 2024, 237
  • [47] Energy performance gap of a nearly Zero Energy Building (nZEB) in Denmark: the influence of occupancy modelling
    Carpino, C.
    Loukou, E.
    Heiselberg, P.
    Arcuri, N.
    BUILDING RESEARCH AND INFORMATION, 2020, 48 (08): : 899 - 921
  • [48] Energy performance gap of a nearly Zero Energy Building (nZEB) in Denmark: The influence of occupancy modelling
    Carpino, C.
    Loukou, E.
    Heiselberg, P.
    Arcuri, N.
    JOURNAL OF PLANNING LITERATURE, 2022, 37 (01) : 200 - 201
  • [49] An Effective Methodology for the Optimal Sizing of the Renewable Energy Sources and Energy Storage System in a Nearly Zero Energy Building
    Tsioumas, Evangelos
    Papagiannis, Dimitrios
    Koseoglou, Markos
    Jabbour, Nikolaos
    Mademlis, Christos
    2020 8TH INTERNATIONAL CONFERENCE ON SMART GRID AND CLEAN ENERGY TECHNOLOGIES (ICSGCE 2020), 2020, : 46 - 51
  • [50] Nearly Zero Energy Building (nZEB) in Latvia
    Kamenders, Agris
    Rusenieks, Rihards
    Vanaga, Ruta
    Rochas, Claudio
    Blumberga, Andra
    9TH INTERNATIONAL CONFERENCE ENVIRONMENTAL ENGINEERING (9TH ICEE) - SELECTED PAPERS, 2014,