An Ultrafine No-Core Fiber-Based Sensor for Simultaneous Liquid Level and Temperature Measurement

被引:6
|
作者
Song, Dianchang [1 ]
Liu, Wei [1 ]
Yin, Zhiyuan [1 ]
Wang, Qi [1 ]
Yan, Xin [1 ]
Zhang, Xuenan [1 ]
Wang, Fang [1 ]
Suzuki, Takenobu [2 ]
Ohishi, Yasutake [2 ]
Qin, Yu [3 ]
Shen, Yichun [3 ]
Zhang, Zelin [3 ]
Cheng, Tonglei [1 ]
机构
[1] Northeastern Univ, Coll Informat Sci & Engn, State Key Lab Synthet Automat Proc Ind, Shenyang 110819, Peoples R China
[2] Toyota Technol Inst, Res Ctr Adv Photon Technol, Nagoya 4688511, Japan
[3] Zhongtian Technol Adv Mat Co Ltd, Nantong 226009, Peoples R China
基金
中国博士后科学基金; 日本学术振兴会;
关键词
Dual-parameter measurement; liquid-level monitoring; multimode interference (MMI); no-core fiber (NCF); SINGLE-MODE FIBER; MACH-ZEHNDER INTERFEROMETER; INTERFERENCE; LASER; TAPER;
D O I
10.1109/JSEN.2023.3282607
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this article, a section of ultrafine no-core fiber (UNCF) is fused between two sections of single-mode fiber (SMF) to form a multimode interference (MMI)-based sensor, which enables dual-parameter measurement of liquid level and temperature. The effect of UNCF diameter on the liquid-level sensing performance is analyzed theoretically and experimentally, and the results show that the sensitivity can be improved by reducing the UNCF diameter. When the UNCF diameter is reduced to 30 mu m, the sensitivity of the sensor is 1008.2 pm/mm for water with a refractive index (RI) of 1.333 in the liquid-level range of 0-30 mm. Its temperature sensitivity is -221.02 pm/degrees C over a detection range of 5 degrees C-60 degrees C. Attractively, the sensor shows almost no response to pressure variation. When applied to the liquid-level measurement of a water cooler, the sensitivity is 1898 pm/mm. The sensor has the advantages of high sensitivity, good repeatability and stability, and satisfactory anti-interference ability. It has great potential for applications in the health management of lasers, chips, transformers, and other instruments.
引用
收藏
页码:15628 / 15636
页数:9
相关论文
共 50 条
  • [31] Optical Fiber Sensor for Simultaneous Measurement of Temperature, Humidity, and Strain Based on Hollow Core Fiber
    Chen Ming
    Chang Jianhua
    Xu Yao
    Jin Aobo
    Hu Ziyi
    ACTA OPTICA SINICA, 2023, 43 (23)
  • [32] High-sensitivity refractive index sensor based on ultrafine conical no-core optical fiber
    Qi, Yuxuan
    Liu, Hailong
    Chen, Ying
    Lv, Jiacheng
    Liu, Yubo
    Zhao, Yanjie
    Ni, Jiasheng
    OPTICAL FIBER TECHNOLOGY, 2025, 91
  • [33] Optical Fiber-Based Level Sensor for High Temperature Applications
    Becker, Kyle F.
    Anderson, Mark H.
    IEEE SENSORS JOURNAL, 2020, 20 (16) : 9187 - 9195
  • [34] Simultaneous Measurement of Temperature and Pressure Based on Ring-Shaped Sensing Structure With Polymer Coated No-Core Fiber
    Zhao, Jian
    Zhao, Yong
    Lv, Ri-Qing
    Li, Xue-Gang
    Zhu, Cheng-Liang
    Zhao, Qiang
    IEEE SENSORS JOURNAL, 2021, 21 (20) : 22783 - 22791
  • [35] Optical fiber hydrogen sensor based on a no-core fiber structure
    Zhang, Xuhui
    Liu, Yun
    Liu, Qiang
    Yuan, Huizhen
    Lu, Mengdi
    Chu, Shuwen
    Peng, Wei
    ELEVENTH INTERNATIONAL CONFERENCE ON INFORMATION OPTICS AND PHOTONICS (CIOP 2019), 2019, 11209
  • [36] In-line reflected fiber sensor for simultaneous measurement of temperature and liquid level based on tapered few-mode fiber
    Li, Yichun
    Song, Zhuo
    Pan, Jiao
    Lu, Hanglin
    Hu, Junhui
    OPTICS EXPRESS, 2022, 30 (05) : 7870 - 7882
  • [37] Hybrid sensor based on microstructured hollow core fiber for simultaneous measurement of strain and temperature
    Ferreira, M. S.
    Bierlich, J.
    Kobelke, J.
    Pinto, J. L.
    Schuster, K.
    Wondraczek, K.
    PHOTONIC INSTRUMENTATION ENGINEERING VI, 2019, 10925
  • [38] No-Core Hollow Fiber-Based SPR Sensor for Ultra-Wide Range of Refractive Index Detection
    Meng, Ge
    Luan, Nannan
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2024, 36 (13) : 861 - 864
  • [39] A broadband SPR sensor based on a no-core fiber coated with gold-silver for refractive index and temperature measurement
    Yin, Zhiyong
    Li, Kaifeng
    Jing, Xili
    Ullah, Sajid
    Zhang, Zhibing
    INFRARED PHYSICS & TECHNOLOGY, 2023, 132
  • [40] Thin fiber-based Mach-Zehnder interferometric sensor for measurement of liquid level, refractive index, temperature, and axial strain
    Liu, Wei
    Wu, Xuqiang
    Zhang, Gang
    Li, Shili
    Zuo, Cheng
    Zhang, Wujun
    Yu, Benli
    APPLIED OPTICS, 2020, 59 (06) : 1786 - 1792