Feasibility of implementing a megavoltage ionization chamber calibration service at the secondary standards level

被引:0
|
作者
Walter, Autumn E. [1 ,2 ]
DeWerd, Larry A. [1 ]
机构
[1] Univ Wisconsin, Sch Med & Publ Hlth, Dept Med Phys, Madison, WI 53705 USA
[2] 1111 Highland Ave B1002, Madison, WI 53705 USA
关键词
Calibrations; Megavoltage; Ionization chambers; Radiation therapy; Radiation physics; K(Q) FACTORS; PHOTON BEAMS;
D O I
10.1016/j.radphyschem.2022.110699
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The purpose of this work was to investigate the feasibility of implementing a megavoltage calibration service for ionization chambers at the secondary standards level. Three reference-class ionization chambers were taken to the National Research Council (NRC) Canada for their primary megavoltage calibration service. Quadratic fits were applied to this data and used to determine calibration coefficients specific to the University of Wisconsin Medical Radiation Research Center (UWMRRC) beam qualities. The primary data and UWMRRC data were used to cross calibrate the three chambers. The resulting calibration coefficients were compared to the NRC values and agreement within 1% was observed. The uncertainty budgets developed for this secondary calibration service were found to be at the same level as those provided for a60Co calibration service at the secondary level. These results indicate that this type of service is feasible at the secondary standards level with the same level of un-certainty as the current standard of practice.
引用
收藏
页数:7
相关论文
共 10 条
  • [2] CALIBRATION OF IONIZATION CHAMBER IN MEGAVOLTAGE X-RAY FIELD OF MEDICAL LINEAR ACCELERATOR
    Hong-Lam Pham
    Thanh-Phi-Hung Hoang
    Jin Sunjun
    Duy-Linh Bui
    Tuan-Khai Nguyen
    Van-Loat Bui
    Tuan-Anh Le
    Huu-Quyet Nguyen
    Duc-Khue Pham
    Viet-Cuong Phan
    Tien-Dung Phan
    Quang-Trung Pham
    Hoai-Nam Tran
    Ngoc-Thiem Le
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2024, 39 (03): : 220 - 225
  • [3] Study on Pulsed X Ray Secondary Standard Ionization Chamber and Calibration Technology
    Gao F.
    Xu Y.
    Liu Y.
    Chen D.
    Ni N.
    Wang F.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2019, 53 (11): : 2257 - 2266
  • [4] Calibration and consistency of results of an ionization-chamber secondary standard measuring system for activity
    Schrader, H
    APPLIED RADIATION AND ISOTOPES, 2000, 52 (03) : 325 - 334
  • [5] Response and Monte Carlo evaluation of a reference ionization chamber for radioprotection level at calibration laboratories
    Neves, Lucio P.
    Vivolo, Vitor
    Perini, Ana P.
    Caldas, Linda V. E.
    RADIATION PHYSICS AND CHEMISTRY, 2015, 112 : 158 - 162
  • [6] Development of a secondary standard ionization chamber for environmental level ambient dose equivalent measurement
    Xu, Yang
    Gao, Fei
    Ni, Ning
    Wang, Feifei
    Liu, Yuntao
    Lin, Min
    APPLIED RADIATION AND ISOTOPES, 2022, 180
  • [7] Calibration of the LNMRI Secondary Standard Ionization Chamber for 131I capsules used in nuclear medicine
    Chaves, Taina Olivieri
    Iwahara, Akira
    Tauhata, Luiz
    Rezende, Eduarda Alexandre
    Correia, Amanda Ribeiro
    de Oliveira, Estela Maria
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2012, 293 (01) : 211 - 216
  • [8] Calibration of the LNMRI Secondary Standard Ionization Chamber for 131I capsules used in nuclear medicine
    Tainá Olivieri Chaves
    Akira Iwahara
    Luiz Tauhata
    Eduarda Alexandre Rezende
    Amanda Ribeiro Correia
    Estela Maria de Oliveira
    Journal of Radioanalytical and Nuclear Chemistry, 2012, 293 : 211 - 216
  • [9] Quantifying health facility service readiness for small and sick newborn care: comparing standards-based and WHO level-2 + scoring for 64 hospitals implementing with NEST360 in Kenya, Malawi, Nigeria, and Tanzania
    Rebecca E. Penzias
    Christine Bohne
    Edith Gicheha
    Elizabeth M. Molyneux
    David Gathara
    Samuel K. Ngwala
    Evelyn Zimba
    Ekran Rashid
    Opeyemi Odedere
    Olabisi Dosunmu
    Robert Tillya
    Josephine Shabani
    James H. Cross
    Christian Ochieng
    Harriet H. Webster
    Msandeni Chiume
    Queen Dube
    John Wainaina
    Irabi Kassim
    Grace Irimu
    Steve Adudans
    Femi James
    Olukemi Tongo
    Veronica Chinyere Ezeaka
    Nahya Salim
    Honorati Masanja
    Maria Oden
    Rebecca Richards-Kortum
    Tedbabe Hailegabriel
    Gagan Gupta
    Simon Cousens
    Joy E. Lawn
    Eric O. Ohuma
    BMC Pediatrics, 23
  • [10] Quantifying health facility service readiness for small and sick newborn care: comparing standards-based and WHO level-2+scoring for 64 hospitals implementing with NEST360 in Kenya, Malawi, Nigeria, and Tanzania
    Penzias, Rebecca E.
    Bohne, Christine
    Gicheha, Edith
    Molyneux, Elizabeth M.
    Gathara, David
    Ngwala, Samuel K.
    Zimba, Evelyn
    Rashid, Ekran
    Odedere, Opeyemi
    Dosunmu, Olabisi
    Tillya, Robert
    Shabani, Josephine
    Cross, James H.
    Ochieng, Christian
    Webster, Harriet H.
    Chiume, Msandeni
    Dube, Queen
    Wainaina, John
    Kassim, Irabi
    Irimu, Grace
    Adudans, Steve
    James, Femi
    Tongo, Olukemi
    Ezeaka, Veronica Chinyere
    Salim, Nahya
    Masanja, Honorati
    Oden, Maria
    Richards-Kortum, Rebecca
    Hailegabriel, Tedbabe
    Gupta, Gagan
    Cousens, Simon
    Lawn, Joy E.
    Ohuma, Eric O.
    Mchoma, Christina
    Bilitinyu, Joseph
    Chalamanda, Pius
    Dzinkambani, Mirriam
    Mhango, Ruth
    Stevens, Fanny
    Mulungu, Joseph
    Makhumula, Blessings
    Banda, Loveness
    Banda, Charles
    Chumbi, Brian
    Banda, Chifundo
    Chimombo, Evelyn
    Nyasulu, Nicodemus
    Ndau, Innocent
    Kumwembe, Pilirani
    Kerubo, Edna
    BMC PEDIATRICS, 2024, 23 (SUPPL 2)