Highly Sensitive, Flow Cytometry-Based Measurement of Intestinal Permeability in Models of Experimental Colitis

被引:1
|
作者
Tsai, Kevin [1 ,2 ]
Ma, Caixia [2 ]
Han, Xiao [2 ]
Allaire, Joannie [2 ]
Lunken, Genelle R. [2 ]
Crowley, Shauna M. [2 ]
Yu, Hongbing [2 ]
Jacobson, Kevan [1 ,2 ]
Xia, Lijun [3 ]
Priatel, John J. [1 ,4 ]
Vallance, Bruce A. [1 ,2 ]
机构
[1] British Columbia Childrens Hosp, Res Inst, Ambulatory Care Bldg,Room K4-188, 4480 Oak St, Vancouver, BC V6H 3V4, Canada
[2] Univ British Columbia, Dept Pediat, Vancouver, BC, Canada
[3] Oklahoma Med Res Fdn, Cardiovasc Biol Res Program, Oklahoma City, OK USA
[4] Univ British Columbia, Dept Pathol & Lab Med, Vancouver, BC, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
Cytometric Bead Assay; Intestinal Permeability Assay; ELISA; Leaky Gut; Inflammatory Bowel Disease; 3-DERIVED O-GLYCANS; MUCUS BARRIER; HEALTH;
D O I
10.1016/j.jcmgh.2022.10.004
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND & AIMS: Increased intestinal permeability is seen in a variety of inflammatory conditions such as enteric infections and inflammatory bowel disease. Because barrier function can provide a key biomarker of disease severity, it often is assayed in animal models. A common methodology involves gavaging mice with fluorescein isothiocyanate-conjugated dextran (FITC-D), followed by cardiac puncture to assay plasma fluorescence on a spectrophotometer. Although the FITC-D method is relatively simple, its sensitivity is limited and enables only a single measurement because the test requires killing the subject. Herein, we describe a novel flow cytometry-based method of intestinal permeability measurement based on detection of orally gavaged ovalbumin (OVA) that leaks out of the gut. Our approach uses minute blood volumes collected from the tail vein, permitting repeated testing of the same subject at multiple time points. By comparing this assay against the gold standard FITC-D method, we show the expanded utility of our OVA assay in measuring intestinal permeability. METHODS: We directly compared our OVA assay against the FITC-D assay by co-administering both probes orally to the same animals and subsequently using their respective methodologies to measure intestinal permeability by detecting probe levels in the plasma. Permeability was assessed in mice genetically deficient in intestinal mucus production or glycosylation. In addition, wild-type mice undergoing dextran sodium sulfate-induced colitis or infected by the enteric bacterial pathogen Citrobacter rodentium also were tested. RESULTS: The OVA assay showed very high efficacy in all animal models of intestinal barrier dysfunction tested. Besides identifying intestinal barrier dysfunction in mice with impaired mucin glycosylation, the assay also allowed for repeated tracking of intestinal permeability within the same animal over time, providing data that cannot be easily acquired with other currently applied methods. CONCLUSIONS: The OVA assay is a highly sensitive and effective method of measuring intestinal permeability in mouse models of barrier dysfunction and experimental colitis.
引用
收藏
页码:425 / 438
页数:14
相关论文
共 50 条
  • [31] Flow Cytometry-based Purification of S. cerevisiae Zygotes
    Rinonos, Serendipity Zapanta
    Saks, Jeremy
    Toska, Jonida
    Ni, Chun-Lun
    Tartakoff, Alan M.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2012, (67):
  • [32] FLOW CYTOMETRY-BASED PROFILING OF IMMUNE CELLS IN ASTHMATIC SPUTUM
    Fricker, Michael
    Erriah, Melanie
    Brooks, Collin
    Simpson, Jodie
    Gibson, Peter G.
    RESPIROLOGY, 2017, 22 : 103 - 103
  • [33] Flow Cytometry-Based Characterization of Mast Cells in Human Atherosclerosis
    Kritikou, Eva
    Depuydt, Marie A. C.
    de Vries, Margreet R.
    Mulder, Kevin E.
    Govaert, Arthur M.
    Smit, Marrit D.
    van Duijn, Janine
    Foks, Amanda C.
    Wezel, Anouk
    Smeets, Harm J.
    Sluetter, Bram
    Quax, Paul H. A.
    Kuiper, Johan
    Bot, Ilze
    CELLS, 2019, 8 (04)
  • [34] Flow cytometry-based profiling of immune cells in asthmatic sputum
    Fricker, Michael
    Erriah, Melanie
    Brooks, Collin
    Simpson, Jodie
    Gibson, Peter
    EUROPEAN RESPIRATORY JOURNAL, 2017, 50
  • [35] In vitro flow cytometry-based screening platform for cellulase engineering
    Georgette Körfer
    Christian Pitzler
    Ljubica Vojcic
    Ronny Martinez
    Ulrich Schwaneberg
    Scientific Reports, 6
  • [36] Semicarbazide is not genotoxic in the flow cytometry-based micronucleus assay in vivo
    Abramsson-Zetterberg, L
    Svensson, K
    TOXICOLOGY LETTERS, 2005, 155 (02) : 211 - 217
  • [37] Tips and tricks for flow cytometry-based analysis and counting of microparticles
    Poncelet, Philippe
    Robert, Stephane
    Bailly, Nicolas
    Garnache-Ottou, Francine
    Bouriche, Tank
    Devalet, Berangere
    Segatchian, Jerard H.
    Saas, Philippe
    Mullier, Francois
    TRANSFUSION AND APHERESIS SCIENCE, 2015, 53 (02) : 110 - 126
  • [38] A Flow Cytometry-Based Screening System for Directed Evolution of Proteases
    Tu, Ran
    Martinez, Ronny
    Prodanovic, Radivoje
    Klein, Mathias
    Schwaneberg, Ulrich
    JOURNAL OF BIOMOLECULAR SCREENING, 2011, 16 (03) : 285 - 294
  • [39] Flow Cytometry-Based Method To Detect Persisters in Candida albicans
    Chang, Wenqiang
    Zhang, Ming
    Li, Ying
    Lou, Hongxiang
    ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2015, 59 (08) : 5044 - 5048
  • [40] Flow Cytometry-based Assay for the Monitoring of NK Cell Functions
    Tognarelli, Sara
    Jacobs, Benedikt
    Staiger, Nina
    Ullrich, Evelyn
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2016, (116):