Highly Sensitive, Flow Cytometry-Based Measurement of Intestinal Permeability in Models of Experimental Colitis

被引:1
|
作者
Tsai, Kevin [1 ,2 ]
Ma, Caixia [2 ]
Han, Xiao [2 ]
Allaire, Joannie [2 ]
Lunken, Genelle R. [2 ]
Crowley, Shauna M. [2 ]
Yu, Hongbing [2 ]
Jacobson, Kevan [1 ,2 ]
Xia, Lijun [3 ]
Priatel, John J. [1 ,4 ]
Vallance, Bruce A. [1 ,2 ]
机构
[1] British Columbia Childrens Hosp, Res Inst, Ambulatory Care Bldg,Room K4-188, 4480 Oak St, Vancouver, BC V6H 3V4, Canada
[2] Univ British Columbia, Dept Pediat, Vancouver, BC, Canada
[3] Oklahoma Med Res Fdn, Cardiovasc Biol Res Program, Oklahoma City, OK USA
[4] Univ British Columbia, Dept Pathol & Lab Med, Vancouver, BC, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
Cytometric Bead Assay; Intestinal Permeability Assay; ELISA; Leaky Gut; Inflammatory Bowel Disease; 3-DERIVED O-GLYCANS; MUCUS BARRIER; HEALTH;
D O I
10.1016/j.jcmgh.2022.10.004
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND & AIMS: Increased intestinal permeability is seen in a variety of inflammatory conditions such as enteric infections and inflammatory bowel disease. Because barrier function can provide a key biomarker of disease severity, it often is assayed in animal models. A common methodology involves gavaging mice with fluorescein isothiocyanate-conjugated dextran (FITC-D), followed by cardiac puncture to assay plasma fluorescence on a spectrophotometer. Although the FITC-D method is relatively simple, its sensitivity is limited and enables only a single measurement because the test requires killing the subject. Herein, we describe a novel flow cytometry-based method of intestinal permeability measurement based on detection of orally gavaged ovalbumin (OVA) that leaks out of the gut. Our approach uses minute blood volumes collected from the tail vein, permitting repeated testing of the same subject at multiple time points. By comparing this assay against the gold standard FITC-D method, we show the expanded utility of our OVA assay in measuring intestinal permeability. METHODS: We directly compared our OVA assay against the FITC-D assay by co-administering both probes orally to the same animals and subsequently using their respective methodologies to measure intestinal permeability by detecting probe levels in the plasma. Permeability was assessed in mice genetically deficient in intestinal mucus production or glycosylation. In addition, wild-type mice undergoing dextran sodium sulfate-induced colitis or infected by the enteric bacterial pathogen Citrobacter rodentium also were tested. RESULTS: The OVA assay showed very high efficacy in all animal models of intestinal barrier dysfunction tested. Besides identifying intestinal barrier dysfunction in mice with impaired mucin glycosylation, the assay also allowed for repeated tracking of intestinal permeability within the same animal over time, providing data that cannot be easily acquired with other currently applied methods. CONCLUSIONS: The OVA assay is a highly sensitive and effective method of measuring intestinal permeability in mouse models of barrier dysfunction and experimental colitis.
引用
收藏
页码:425 / 438
页数:14
相关论文
共 50 条
  • [1] Flow Cytometry-based Measurement of Reactive Oxygen Species in Cyanobacteria
    Mondal, Soumila
    Singh, Shailendra P.
    BIO-PROTOCOL, 2022, 12 (10):
  • [2] An automated analysis of highly complex flow cytometry-based proteomic data
    Stuchly, Jan
    Kanderova, Veronika
    Fiser, Karel
    Cerna, Daniela
    Holm, Anders
    Wu, Weiwei
    Hrusak, Ondrej
    Lund-Johansen, Fridtjof
    Kalina, Tomas
    CYTOMETRY PART A, 2012, 81A (02) : 120 - 129
  • [3] Improvements in Flow Cytometry-Based Cytotoxicity Assay
    Wu, Xiaolong
    Zhang, Ying
    Li, Yutao
    Schmidt-Wolf, Ingo G. H.
    CYTOMETRY PART A, 2021, 99 (07) : 680 - 688
  • [4] A flow cytometry-based screen for synthetic riboswitches
    Lynch, Sean A.
    Gallivan, Justin P.
    NUCLEIC ACIDS RESEARCH, 2009, 37 (01) : 184 - 192
  • [5] A flow cytometry-based diagnosis of eosinophilic esophagitis
    Wen, Ting
    Kuhl, Jonathan
    Putnam, Philip
    Mukkada, Vincent
    Farrell, Michael
    Kaul, Ajay
    Cole, Conrad
    Rothenberg, Marc E.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2017, 140 (06) : 1736 - +
  • [6] A Flow Cytometry-Based Assay for the Measurement of Total Complement Activity in the Serum and Clinical Practice
    Ding, Xuewei
    Li, Shijun
    Liu, Hui
    DISEASE MARKERS, 2022, 2022
  • [7] A Flow Cytometry-Based Assay for Procoagulant Platelet Polyphosphate
    Labberton, Linda
    Long, Andy T.
    Gendler, Sandra J.
    Snozek, Christine L.
    Stavrou, Evi X.
    Nickel, Katrin F.
    Maas, Coen
    Blankenberg, Stefan
    Hernandez, James S.
    Renne, Thomas
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2018, 94 (02) : 369 - 373
  • [8] Validation of the Flow Cytometry-Based In Vitro Micronucleus Assay
    Zhou, C.
    Ou, H.
    Tu, H.
    Xu, L.
    Chang, Y.
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2015, 56 : S73 - S73
  • [9] A novel flow cytometry-based platelet aggregation assay
    De Cuyper, Iris M.
    Meinders, Marjolein
    van de Vijver, Edith
    de Korte, Dirk
    Porcelijn, Leendert
    de Haas, Masja
    Eble, Johannes A.
    Seeger, Karl
    Rutella, Sergio
    Pagliara, Daria
    Kuijpers, Taco W.
    Verhoeven, Arthur J.
    van den Berg, Timo K.
    Gutierrez, Laura
    BLOOD, 2013, 121 (10) : E70 - E80
  • [10] Detecting endotoxin with a flow cytometry-based magnetic aptasensor
    Zuo, Ming-Yan
    Chen, Li-Juan
    Jiang, Hao
    Tan, Lin
    Luo, Zhao-Feng
    Wang, Yan-Mei
    ANALYTICAL BIOCHEMISTRY, 2014, 466 : 38 - 43