A Method for Evaluating Robustness of Limited Sampling Strategies-Exemplified by Serum Iohexol Clearance for Determination of Measured Glomerular Filtration Rate

被引:3
|
作者
Hovd, Markus [1 ]
Robertsen, Ida [1 ]
Woillard, Jean-Baptiste [2 ]
Asberg, Anders [1 ,3 ]
机构
[1] Univ Oslo, Dept Pharm, Sect Pharmacol & Pharmaceut Biosci, POB 1068, N-0316 Oslo, Norway
[2] Univ Limoges, CHU Limoges, Inserm, U 1248,Pharmacol & Toxicol, F-87000 Limoges, France
[3] Oslo Univ Hosp, Dept Transplantat Med, POB 4950, N-0424 Oslo, Norway
关键词
limited sampling strategies; population pharmacokinetic modelling; semi-parametric simulation; robustness; therapeutic drug monitoring; area under the curve; AUC; glomerular filtration rate; GFR; PLASMA-CLEARANCE; PACKAGE;
D O I
10.3390/pharmaceutics15041073
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
In combination with Bayesian estimates based on a population pharmacokinetic model, limited sampling strategies (LSS) may reduce the number of samples required for individual pharmacokinetic parameter estimations. Such strategies reduce the burden when assessing the area under the concentration versus time curves (AUC) in therapeutic drug monitoring. However, it is not uncommon for the actual sample time to deviate from the optimal one. In this work, we evaluate the robustness of parameter estimations to such deviations in an LSS. A previously developed 4-point LSS for estimation of serum iohexol clearance (i.e., dose/AUC) was used to exemplify the effect of sample time deviations. Two parallel strategies were used: (a) shifting the exact sampling time by an empirical amount of time for each of the four individual sample points, and (b) introducing a random error across all sample points. The investigated iohexol LSS appeared robust to deviations from optimal sample times, both across individual and multiple sample points. The proportion of individuals with a relative error greater than 15% (P15) was 5.3% in the reference run with optimally timed sampling, which increased to a maximum of 8.3% following the introduction of random error in sample time across all four time points. We propose to apply the present method for the validation of LSS developed for clinical use.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Dosage of iohexol in serum and urine by HPLC-UV for direct measurement of glomerular filtration rate: matrix effect, stability and development of the method
    El Assri, S.
    Sebbar, E.
    Bentata, Y.
    Choukri, M.
    CLINICA CHIMICA ACTA, 2022, 530 : S40 - S40
  • [42] Evaluating chronic kidney disease in rural South Africa: comparing estimated glomerular filtration rate using point-of-care creatinine to iohexol measured GFR
    Currin, Sean
    Gondwe, Mwawi
    Mayindi, Nokthula
    Chipungu, Shingirai
    Khoza, Bongekile
    Khambule, Lungile
    Snyman, Tracy
    Tollman, Stephen
    Fabian, June
    George, Jaya
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (08) : 1409 - 1420
  • [43] Determination of the production rate and non-renal clearance of cystatin C and estimation of the glomerular filtration rate from the serum concentration of cystatin C in humans
    Sjöström, P
    Tidman, M
    Jones, I
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2005, 65 (02): : 111 - 124
  • [44] OPTIMUM TIME OF BLOOD-SAMPLING FOR DETERMINATION OF GLOMERULAR-FILTRATION RATE BY SINGLE-INJECTION [EDTA-CR-51] PLASMA CLEARANCE
    BROCHNERMORTENSEN, J
    RODBRO, P
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1976, 36 (08): : 795 - 800
  • [45] Determination of iohexol and its application to glomerular filtration rate estimation: validation of a new UPLC-MS/MS method with ICP-MS comparable performances
    Djerada, Z.
    Canot, B.
    Gozalo, C.
    Marty, H.
    Lamiable, D.
    Rieu, P.
    Millart, H.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2012, 26 : 121 - 121
  • [46] Comparison of methods for determination of glomerular filtration rate: Tc-99m-DTPA renography, predicted creatinine clearance method and plasma sample method
    Kazuo Itoh
    Annals of Nuclear Medicine, 2003, 17 : 561 - 565
  • [47] Comparison of methods for determination of glomerular filtration rate: Tc-99m-DTPA renography, predicted creatinine clearance method and plasma sample method
    Itoh, K
    ANNALS OF NUCLEAR MEDICINE, 2003, 17 (07) : 561 - 565
  • [48] DETERMINATION OF GLOMERULAR-FILTRATION RATE (GFR) ON 2 CONSECUTIVE DAYS USING INSULIN IN A SINGLE-SAMPLE PLASMA-CLEARANCE METHOD
    SCHUMANN, L
    WUSTENBERG, PW
    HORTIAN, B
    KUHNLE, HF
    CLINICAL NEPHROLOGY, 1993, 39 (02) : 65 - 69
  • [49] USE OF A SINGLE INJECTION SOLUTE-CLEARANCE METHOD FOR DETERMINATION OF GLOMERULAR-FILTRATION RATE AND EFFECTIVE RENAL PLASMA-FLOW IN CHICKENS
    RADIN, MJ
    HOEPF, TM
    SWAYNE, DE
    LABORATORY ANIMAL SCIENCE, 1993, 43 (06): : 594 - 596
  • [50] A SINGLE PLASMA SAMPLE METHOD FOR ESTIMATION OF THE GLOMERULAR-FILTRATION RATE IN INFANTS AND CHILDREN USING IOHEXOL, .2. ESTABLISHMENT OF THE OPTIMAL PLASMA SAMPLING TIME AND A COMPARISON WITH THE 99TCM-DTPA METHOD
    STAKE, G
    MONN, E
    ROOTWELT, K
    MONCLAIR, T
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1991, 51 (04): : 343 - 348