摘要
In combination with Bayesian estimates based on a population pharmacokinetic model, limited sampling strategies (LSS) may reduce the number of samples required for individual pharmacokinetic parameter estimations. Such strategies reduce the burden when assessing the area under the concentration versus time curves (AUC) in therapeutic drug monitoring. However, it is not uncommon for the actual sample time to deviate from the optimal one. In this work, we evaluate the robustness of parameter estimations to such deviations in an LSS. A previously developed 4-point LSS for estimation of serum iohexol clearance (i.e., dose/AUC) was used to exemplify the effect of sample time deviations. Two parallel strategies were used: (a) shifting the exact sampling time by an empirical amount of time for each of the four individual sample points, and (b) introducing a random error across all sample points. The investigated iohexol LSS appeared robust to deviations from optimal sample times, both across individual and multiple sample points. The proportion of individuals with a relative error greater than 15% (P15) was 5.3% in the reference run with optimally timed sampling, which increased to a maximum of 8.3% following the introduction of random error in sample time across all four time points. We propose to apply the present method for the validation of LSS developed for clinical use.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] DETERMINATION OF GLOMERULAR-FILTRATION RATE USING IOHEXOL CLEARANCE AND CAPILLARY SAMPLING
    KRUTZEN, E
    BACK, SE
    NILSSONEHLE, P
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1990, 50 (03): : 279 - 283
  • [2] DETERMINATION OF GLOMERULAR-FILTRATION RATE BY IOHEXOL CLEARANCE
    NILSSONEHLE, P
    ANNALES DE BIOLOGIE CLINIQUE, 1993, 51 (3-5) : 322 - 322
  • [3] Applicability of estimating glomerular filtration rate equations in pediatric patients: comparison with a measured glomerular filtration rate by iohexol clearance
    Deng, Fang
    Finer, Gal
    Haymond, Shannon
    Brooks, Ellen
    Langman, Craig B.
    TRANSLATIONAL RESEARCH, 2015, 165 (03) : 437 - 445
  • [4] DETERMINATION OF LOW GLOMERULAR-FILTRATION RATE USING IOHEXOL CLEARANCE
    FRENNBY, B
    STERNER, G
    ALMEN, T
    HAGSTAM, KE
    JACOBSSON, L
    INVESTIGATIVE RADIOLOGY, 1994, 29 : S234 - S235
  • [5] Iohexol Clearance for Determination of Glomerular Filtration Rate in Cynomolgus Monkeys (Macaca fascicularis)
    Zhang, Changqing
    Ding, Shanshan
    Fang, Yupeng
    Zhang, Li
    Hu, Weimin
    Lu, Jinlian
    Jing, Tao
    Tao, Yi
    Zhang, Xin
    JOURNAL OF THE AMERICAN ASSOCIATION FOR LABORATORY ANIMAL SCIENCE, 2017, 56 (03): : 330 - 333
  • [6] Glomerular filtration rate measured by iohexol clearance: A comparison of venous samples and capillary blood spots
    Salvador, Cathrin Lytomt
    Tondel, Camilla
    Morkrid, Lars
    Bjerre, Anna
    Brun, Atle
    Bolann, Bjorn
    Brackman, Damien
    Bergan, Stein
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2015, 75 (08): : 710 - 716
  • [7] Iohexol Clearance for Determination of Glomerular Filtration Rate in Rats Induced to Acute Renal Failure
    Passos, Michelle T.
    Nishida, Sonia K.
    Camara, Niels O. S.
    Shimizu, Maria Heloisa
    Mastroianni-Kirsztajn, Gianna
    PLOS ONE, 2015, 10 (04):
  • [8] Glomerular filtration rate determination in diabetic patients using iohexol clearance - comparison of single and multiple plasma sampling methods
    Chowdhury, TA
    Dyer, PH
    Bartlett, WA
    Legge, ES
    Durbin, SM
    Barnett, AH
    Bain, SC
    CLINICA CHIMICA ACTA, 1998, 277 (02) : 153 - 158
  • [9] Simplified Method to Measure Glomerular Filtration Rate by Iohexol Plasma Clearance in Conscious Rats
    Carrara, Fabiola
    Azzollini, Nadia
    Nattino, Giovanni
    Corna, Daniela
    Villa, Sebastian
    Cerullo, Domenico
    Zoja, Carlamaria
    Abrante, Beatriz
    Luis-Lima, Sergio
    Porrini, Esteban
    Cannata, Antonio
    Ferrari, Silvia
    Fois, Matteo
    Stucchi, Nadia
    Gaspari, Flavio
    NEPHRON, 2016, 133 (01) : 62 - 70
  • [10] PLASMA AND RENAL CLEARANCE OF IOHEXOL - A STUDY ON THE REPRODUCIBILITY OF A METHOD FOR THE GLOMERULAR-FILTRATION RATE
    ARVIDSSON, A
    HEDMAN, A
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1990, 50 (07): : 757 - 761