Ratiometric fluorescence aptasensor for the detection of patulin in apple juice based on the octahedral UiO-66-TCPP metal-organic framework and aptamer systems

被引:8
|
作者
Yan, Xiaohai [1 ,2 ]
Yuan, Yahong [1 ,2 ,3 ]
Yue, Tianli [1 ,2 ,3 ]
机构
[1] Northwest A&F Univ, Coll Food Sci & Engn, Yangling 712100, Peoples R China
[2] Minist Agr, Lab Qual & Safety Risk Assessment Agroprod Yanglin, Yangling 712100, Peoples R China
[3] Northwest Univ, Coll Food Sci & Technol, Xian 710067, Peoples R China
关键词
Ratiometric fluorescence aptasensor; Metal-organic framework; Tetrakis(4-carboxyphenyl)porphyrin; Detection; Patulin; Apple juice; CONSTRUCTION; TOXICITY;
D O I
10.1016/j.foodchem.2023.137211
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Patulin (PAT) is a potentially harmful mycotoxin to human health and is known to contaminate apple juice. In this work, we developed a ratiometric fluorescence aptasensor using tetrakis(4-carboxyphenyl)porphyrin (H2TCPP)-treated octahedral UiO-66-NH2 (defined as UiO-66-TCPP) to detect PAT. This 2-aminoterephthalic acid and H2TCPP functionalized metal-organic framework showed multiple adsorption effects (hydrogen bonding and & pi;-& pi; stacking) on the aptamer (Apt) and served as a quenching material. When the target PAT bound specifically to the Apt, the fluorescence of the 6-carboxyfluorescein-labeled Apt would recover, and the fluorescence of the H2TCPP ligand remained unchanged. This ratiometric fluorescence property improved the accuracy of PAT detection. Moreover, the introduction of the H2TCPP ligand enhanced the quenching efficiency of UiO-66-NH2, thus improving the sensitivity of the fluorescent aptasensor (UiO-66-TCPP vs. UiO-66-NH2: 0.0162 ng/mL vs. 1.8 ng/mL). In addition, we used UiO-66-TCPP to detect PAT in apple juice samples. This work provides a good paradigm for the construction of ratiometric fluorescence aptasensors with high sensitivity and accuracy.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Functionalized Metal-Organic Framework UiO-66-NH-BQB for Selective Detection of Hydrogen Sulfide and Cysteine
    Yu, Huazheng
    Liu, Chuanyao
    Li, Yanhong
    Huang, Aisheng
    ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (45) : 41972 - 41978
  • [22] Simultaneous and sensitive electrochemical detection of dihydroxybenzene isomers with UiO-66 metal-organic framework/mesoporous carbon
    Deng, Min
    Lin, Shourui
    Bo, Xiangjie
    Guo, Liping
    TALANTA, 2017, 174 : 527 - 538
  • [23] Screening of specific aptamers against chlorpromazine and construction of novel ratiometric fluorescent aptasensor based on metal-organic framework
    Song, Mingqian
    Li, Changxin
    Wu, Shijia
    Duan, Nuo
    TALANTA, 2023, 252
  • [24] Reusable fluorescence nanoprobe based on DNA-functionalized metal-organic framework for ratiometric detection of mercury (II) ions
    Li, Shenghua
    Pi, Jianhui
    Huang, Yingjie
    Li, Yong
    Tan, Hongliang
    MICROCHIMICA ACTA, 2024, 191 (11)
  • [25] Ratiometric fluorescence detection of tetracycline antibiotic based on a polynuclear lanthanide metal–organic framework
    Li, Runxian
    Wang, Wenjing
    El-Sayed, El-Sayed M.
    Su, Kongzhao
    He, Pingli
    Yuan, Daqiang
    Wang, Wenjing (wjwang@fjirsm.ac.cn), 1600, Elsevier B.V. (330):
  • [26] Novel perylene probe-encapsulated metal-organic framework nanocomposites for ratiometric fluorescence detection of ATP
    Zhou, Xiaomeng
    Li, Juanmin
    Tan, Li-Li
    Li, Qiang
    Shang, Li
    JOURNAL OF MATERIALS CHEMISTRY B, 2020, 8 (16) : 3661 - 3666
  • [27] Dual-Ligand Lanthanide Metal-Organic Framework for Sensitive Ratiometric Fluorescence Detection of Hypochlorous Acid
    Sun, Yi-Qing
    Cheng, Yue
    Yin, Xue-Bo
    ANALYTICAL CHEMISTRY, 2021, 93 (07) : 3559 - 3566
  • [28] A dual emission metal-organic framework for rapid ratiometric fluorescence detection of CO32-in seawater
    Wei, Yu
    Xia, Yan
    RSC ADVANCES, 2020, 10 (42) : 24764 - 24771
  • [29] Ratiometric fluorescence detection of trace water in an organic solvent based on bimetallic lanthanide metal-organic frameworks
    Li, Beibei
    Wang, Wenjing
    Hong, Zixiao
    El-Sayed, El-Sayed M.
    Yuan, Daqiang
    CHEMICAL COMMUNICATIONS, 2019, 55 (48) : 6926 - 6929
  • [30] Towards metal-organic framework based field effect chemical sensors: UiO-66-NH2 for nerve agent detection
    Stassen, I.
    Bueken, B.
    Reinsch, H.
    Oudenhoven, J. F. M.
    Wouters, D.
    Hajek, J.
    Van Speybroeck, V.
    Stock, N.
    Vereecken, P. M.
    Van Schaijk, R.
    De Vos, D.
    Ameloot, R.
    CHEMICAL SCIENCE, 2016, 7 (09) : 5827 - 5832