Lung iodine mapping images of acute postpartum dyspnea without pulmonary thromboembolism using dual-energy CT

被引:0
|
作者
Okada, Munemasa [1 ,6 ]
Nomura, Takafumi [2 ]
Kunihiro, Yoshie [3 ]
Takegami, Kazuki [4 ]
Uehara, Takuya [4 ]
Tokurei, Shogo [5 ]
机构
[1] Natl Hosp Org, Kanmon Med Ctr, Shimonoseki, Japan
[2] Ube Kohsan Cent Hosp, Dept Radiol, Ube, Japan
[3] Yamaguchi Univ, Sch Med, Dept Radiol, Ube, Japan
[4] Yamaguchi Univ, Dept Radiol, Ube, Japan
[5] Junshin Gakuen Univ, Fac Hlth Sci, Dept Radiol Sci, Fukuoka, Japan
[6] Dept Radiol, Kanmon Med Ctr, Natl HospitalOrganizat, Chofu-Sotoura1-1, Shimonoseki 7528510, Japan
关键词
Postpartum dyspnea; dual-energy computed tomography; lung iodine mapping; pulmonary vasoconstriction; pulmonary thromboembolism; AMNIOTIC-FLUID EMBOLISM; ANGIOGRAPHY; PERFUSION; OCCLUSION; PATIENT; CELLS;
D O I
10.1177/02841851231174460
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Postpartum dyspnea is commonly observed, but its cause is often unknown. Purpose To investigate postpartum dyspnea, we compared lung iodine mapping (LIM) using dual-energy computed tomography (DECT) between postpartum women and women suspected of having pulmonary thromboembolism (PTE). Material and Methods In this retrospective study, 109 women of reproductive age (50 postpartum women, 59 women unrelated to pregnancy) underwent DECT between March 2009 and August 2020. Among the postpartum women, 23 patients were excluded due to late-onset dyspnea (n=20: >48 h after delivery) or the presence of PTE (n=3). A total of 86 patients were divided into three groups (27 postpartum women [postpartum group], 19 women with PTE [PTE group], and 40 women without PTE [non-PTE group]). Quantitation was applied to a decreased LIM value (LIM5; defined as <5 HU) and the relative value of LIM5 to whole LIM volume (%LIM5). LIM defects were classified into five patterns (0 = none, 1 = wedge-shaped, 2 = reticular/liner, 3 = diffuse granular/patchy, 4 = massive defects) based on a consensus between two readers. Results There were significant differences in the LIM5 and %LIM5 values among the three groups. The LIM5 and %LIM5 were largest in the PTE group, and postpartum women showed intermediate values between the non-PTE and PTE groups. Wedge-shaped defects were prominent in the PTE group, and diffuse granular/patchy defect was a typical feature in the postpartum group. Conclusion Postpartum women with dyspnea showed granular/patchy defects on DECT with a median quantitative value between the PTE and non-PTE groups.
引用
收藏
页码:2401 / 2408
页数:8
相关论文
共 50 条
  • [41] Pulmonary Blood Vessels Extraction from Dual-Energy CT Images using a Synchrotron Radiation Micro-CT
    Saito, K.
    Ohnishi, S.
    Fuketa, S.
    Kawata, Y.
    Niki, N.
    Umetani, K.
    Sakai, H.
    Nakano, Y.
    Okamoto, T.
    Itoh, H.
    MEDICAL IMAGING 2019: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2019, 10953
  • [42] Iodine material density images in dual-energy CT: quantification of contrast uptake and washout in HCC
    Pfeiffer, Daniela
    Parakh, Anushri
    Patino, Manuel
    Kambadakone, Avinash
    Rummeny, Ernst J.
    Sahani, Dushyant V.
    ABDOMINAL RADIOLOGY, 2018, 43 (12) : 3317 - 3323
  • [43] Iodine material density images in dual-energy CT: quantification of contrast uptake and washout in HCC
    Daniela Pfeiffer
    Anushri Parakh
    Manuel Patino
    Avinash Kambadakone
    Ernst J. Rummeny
    Dushyant V. Sahani
    Abdominal Radiology, 2018, 43 : 3317 - 3323
  • [44] Dual-energy CT performance in acute pulmonary embolism: a meta-analysis
    Monti, Caterina B.
    Zanardo, Moreno
    Cozzi, Andrea
    Schiaffino, Simone
    Spagnolo, Pietro
    Secchi, Francesco
    De Cecco, Carlo N.
    Sardanelli, Francesco
    EUROPEAN RADIOLOGY, 2021, 31 (08) : 6248 - 6258
  • [45] Different Perfusion Pattern Between Acute and Chronic Pulmonary Thromboembolism: Evaluation With Two-Phase Dual-Energy Perfusion CT
    Hong, Yoo Jin
    Kim, Ja Young
    Choe, Kyu Ok
    Hur, Jin
    Lee, Hye-Jeong
    Choi, Byoung Wook
    Kim, Young Jin
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (04) : 812 - 817
  • [46] Dual-energy CT performance in acute pulmonary embolism: a meta-analysis
    Caterina B. Monti
    Moreno Zanardo
    Andrea Cozzi
    Simone Schiaffino
    Pietro Spagnolo
    Francesco Secchi
    Carlo N. De Cecco
    Francesco Sardanelli
    European Radiology, 2021, 31 : 6248 - 6258
  • [47] Imaging Depiction of Hypoxic Pulmonary Vasoconstriction Using Dual-Energy CT
    Hunter, Joshua G.
    Prajapati, Priyanka
    Bera, Kaustav
    Gupta, Aekta
    Gupta, Amit
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (03)
  • [48] Dual-Energy CT Iodine Mapping and 40-keV Monoenergetic Applications in the Diagnosis of Acute Bowel Ischemia: A Necessary Clarification
    Mazzei, Maria Antonietta
    Gentili, Francesco
    Volterrani, Luca
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (03) : W93 - W94
  • [49] Advanced virtual monoenergetic images: improving the contrast of dual-energy CT pulmonary angiography
    Meier, A.
    Wurnig, M.
    Desbiolles, L.
    Leschka, S.
    Frauenfelder, T.
    Alkadhi, H.
    CLINICAL RADIOLOGY, 2015, 70 (11) : 1244 - 1251
  • [50] Dual-energy dynamic CT of lung adenocarcinoma: correlation of iodine uptake with tumor gene expression
    Yanagawa, Masahiro
    Morii, Eiichi
    Hata, Akinori
    Fujiwara, Maki
    Gyobu, Tomoko
    Ueda, Ken
    Honda, Osamu
    Tomiyama, Noriyuki
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (08) : 1407 - 1413