Optoelectronics and thermoelectric performances in CuX (X = F, Cl, Br, and I)

被引:0
|
作者
Ghellab, Torkia [1 ,2 ]
Charifi, Zoulikha [1 ,2 ]
Baaziz, Hakim [1 ,2 ]
Latelli, Nadjia [2 ,3 ]
机构
[1] Univ Msila, Fac Sci, Dept Phys, Msila 28000, Algeria
[2] Univ Msila, Lab Phys & Chem Mat, Msila, Algeria
[3] Univ Msila, Fac Sci, Dept Chem, Msila 28000, Algeria
关键词
semiconductors; thermoelectric properties; anisotropy; enhancing ZT; ELECTRONIC-STRUCTURE; BAND-STRUCTURE; OPTICAL-PROPERTIES; ELASTIC PROPERTIES; CUCL; CUBR; POLYMORPHISM; STABILITY; CRYSTALS; HALIDES;
D O I
10.1515/zna-2023-0237
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The current study focused on examining the structural, mechanical, and optoelectronic properties of CuF, CuCl, CuBr, and CuI by the utilisation of the FP-LAPW method. The calculations reveal that GGA is a better fit than LDA for evaluating structural characteristics, including lattice parameters and bulk modulus. The examination of the band structure reveals that CuF exhibits metallic behaviour, whilst the compounds CuCl, CuBr, and CuI exhibit semiconducting properties, characterised by direct fundamental gaps (Gamma -> Gamma) of 0.516, 0.425, and 1.049 eV, respectively. The peak absorption values for CuCl, CuBr, and CuI are located at 10.68 eV, 9.53 eV, and 7.68 eV, respectively. All materials have ultraviolet absorption peaks. Therefore, the compounds demonstrate substantial absorption in the low- and mid-ultraviolet wavelengths. The four compounds exhibit anisotropic properties, possess ductility, and demonstrate mechanical stability. These entities possess the ability to endure a wide range of temperatures. The thermoelectric performance of the three semiconductors, CuCl, CuBr, and CuI, was investigated. At 300 K, the k( L )values for CuBr, CuCl, and CuI, are 2.89 W/mK, 3.98 W/mK, and 3.56 W/mK, and the Gruneisen values are as follows: gamma (CuCl) = 2.4087, gamma (CuBr) = 2.4747, and gamma (CuI) = 2.1962. At a temperature of 600 K, the k( T )value is found to be relatively low. The measured values for the k( T )of CuCl, CuBr, and CuI are around 1.7818 W m(-1) K-1, 1.5109 W m(-1) K-1, and 2.8580 W m(-1) K-1, respectively. At a temperature of 300 K, the Seebeck coefficients (S) for CuCl, CuBr, and CuI are measured to be 1192.7964 mu V/K, 1170.5882 mu V/K, and -65.7454 mu V/K, respectively. At a temperature of 800 K, the p-type compound CuBr exhibits a maximum figure of merit (ZT) value of 0.6691, corresponding to a charge carrier concentration of 31.7926 x 10(20) cm(3). The CuCl and CuI compounds exhibit the maximum ZT values of 0.52043 and 0.5609, respectively. In order to achieve the desired results, it is necessary to decrease the charge carrier concentration in CuCl to n = 0.514 x 10(22) cm(-3) and increase the charge carrier concentration in CuI to n = 9.686 x 10(22) cm(-3); alternatively, the chemical potentials should be decreased by 0.2563 Ryd and 0.3974 Ryd, respectively.
引用
收藏
页码:261 / 282
页数:22
相关论文
共 50 条
  • [21] Coordination polyhedra CrXn (X = F, Cl, Br, I) in crystals
    Serezhkin, VN
    Serezhkina, LB
    Gorbunova, YE
    Buslaev, YA
    RUSSIAN JOURNAL OF INORGANIC CHEMISTRY, 2000, 45 (05) : 741 - 747
  • [22] Coordination polyhedra VXn (X = F, Cl, Br, I) in crystals
    Serezhkina, LB
    Serezhkin, VN
    Buslaev, YA
    ZHURNAL NEORGANICHESKOI KHIMII, 2000, 45 (02): : 288 - 295
  • [23] Electric multipole moments of XeCuX (X = F, Cl, Br, I)
    Maroulis, George
    Chambaud, Gilberte
    CHEMICAL PHYSICS LETTERS, 2018, 693 : 194 - 197
  • [24] Thermoelectric Property Analysis of CsSnX3 Materials (X = I, Br, Cl)
    Yu, Lantao
    Kassem, Wassim
    Bude, Romain
    Divay, Laurent
    Amrit, Jay
    Volz, Sebastian
    2015 21ST INTERNATIONAL WORKSHOP ON THERMAL INVESTIGATIONS OF ICS AND SYSTEMS (THERMINIC), 2015,
  • [25] IONIC-CONDUCTION IN LIX-BASED AND CUX-BASED GLASSES (X = CL, BR, I)
    KADONO, K
    MITANI, K
    YAMASHITA, M
    TANAKA, H
    KAWAMOTO, Y
    OHNO, K
    KANNO, R
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 1992, 140 (1-3) : 103 - 106
  • [26] COMPARATIVE STUDY OF HYDROXYHALIDES CD(OH)X (X=F, CL, BR, I)
    WALTERLE.L
    GROULT, MD
    COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES SERIE C, 1970, 271 (20): : 1245 - &
  • [27] The accuracy of density functionals for electric field gradients. Test calculations for ScX, CuX and GaX (X=F, Cl, Br, I, H and Li)
    Bast, R
    Schwerdtfeger, P
    JOURNAL OF CHEMICAL PHYSICS, 2003, 119 (12): : 5988 - 5994
  • [28] DFT study of structural, electronic, thermoelectric and elastic properties of KPdX3 (X = F, Cl, Br, and I) perovskites
    Shafiullah, Muhammad
    Haq, Saeed Ul
    Muhammad, Raz
    Faizan, Muhammad
    Laref, Amel
    Derafa, Wassila
    Sohail, Amir
    Khesro, Amir
    Samad, Abdus
    PHYSICA SCRIPTA, 2023, 98 (06)
  • [29] Selective vibrational excitations in the OX (X = F, Cl, Br, I) molecules
    Léonard, C
    Le Quéré, F
    Rosmus, P
    Puzzarini, C
    Castells, MPD
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2000, 2 (06) : 1117 - 1122
  • [30] Coordination polyhedra CdXn (X = F, Cl, Br, or I) in crystal structures
    Serezhkin, VN
    Serezhkina, LB
    Bakhmet'eva, LM
    ZHURNAL NEORGANICHESKOI KHIMII, 2000, 45 (03): : 489 - 498