Hemodynamic Wall Shear Stress Measurements Using Ultrasound Feature Tracking Algorithm

被引:0
|
作者
Park, Dong Chan [1 ]
Park, Dae Woo [1 ]
Chang, Jun Geun [1 ]
机构
[1] Natl Canc Ctr, Res Inst & Hosp, Diagnost & Therapeut Technol Branch, 323 Ilsan Ro, Goyang Si 10408, Gyeonggi Do, South Korea
关键词
Ultrasound; Wall shear stress; Wall shear rate; Blood flow; Ultrasound feature tracking; PARTICLE IMAGE VELOCIMETRY; SPECKLE TRACKING; IN-VITRO; FLOW; QUANTIFICATION;
D O I
10.1007/s42835-023-01489-w
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Accurate wall shear rate (WSR) measurements are important for the early diagnosis of cardiovascular disease progression and acute events, such as atherosclerotic plaque rupture and aneurysm rupture. The Kanade-Lucas-Tomasi (KLT) feature tracking is an ultrasound imaging technique and competitive candidate for WSR measurements. In this study, we hypothesized that the accuracy of WSR measurements can be improved using KLT feature tracking. Thereby, we aimed to evaluate the accuracy of KLT feature tracking for flow velocities and WSR measurements by comparing the results with those from the conventional two-dimensional ultrasound speckle tracking (2D-UST) technique. An in-vitro flow experiment was performed using a flow phantom, and blood flow velocity profiles were generated using KLT feature tracking and the 2D-UST algorithm. A quantitative error analysis was performed for the flow velocities and WSRs measured using both methods based on the analytical values. The WSRs measured using KLT feature tracking demonstrated significantly higher agreement with the analytical values than those measured using 2D-UST. The measured WSRs using KLT feature tracking were found to match the analytical values with absolute errors of 0.9% and 14.4% at the top and bottom luminal walls, respectively. By contrast, the estimated WSRs using the 2D-UST algorithm were found to be in poor agreement with the analytical values, with absolute errors of 80.7% and 67.1% at the top and bottom luminal walls, respectively. Therefore, our results demonstrate the feasibility of KLT feature tracking for clinical application of in-vivo wall shear stress measurements.
引用
收藏
页码:3111 / 3116
页数:6
相关论文
共 50 条
  • [31] Wall pressure and shear stress measurements beneath an impinging jet
    Tu, CV
    Wood, DH
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1996, 13 (04) : 364 - 373
  • [32] WALL SHEAR STRESS MEASUREMENTS ON A HIGHLY LOADED COMPRESSOR CASCADE
    Zander, Vincent
    Dobriloff, Christoph
    Lumpe, Mathias
    Nitsche, Wolfgang
    PROCEEDINGS OF THE ASME TURBO EXPO 2011, VOL 7, PTS A-C, 2012, : 359 - 368
  • [33] WALL SHEAR-STRESS MEASUREMENTS IN CONFINED VORTICAL FLOW
    DESANTIS, MJ
    RAKOWSKY, EL
    PAGE, RH
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1972, 17 (11): : 1110 - 1110
  • [34] Mean wall-shear stress measurements using the micro-pillar shear-stress sensor MPS3
    Grosse, S.
    Schroeder, W.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (01)
  • [35] MEASUREMENTS OF WALL SHEAR STRESS DISTRIBUTION FOR FLOW AROUND A CYLINDER
    DIMOPOUL.HG
    HANRATTY, TJ
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1968, 13 (05): : 818 - &
  • [36] Fluid-structure interaction approach in hemodynamic wall shear stress analysis
    Kanyanta, V.
    Ivankovic, A.
    Karac, A.
    PROCEEDINGS OF THE FIFTH IASTED INTERNATIONAL CONFERENCE ON BIOMECHANICS, 2007, : 93 - +
  • [37] Spatial Resolution Correction for Electrochemical Wall-shear Stress Measurements using Rectangular Sensors
    Fadla, F.
    Chovet, R.
    Cornu, D.
    Lippert, M.
    Aloui, F.
    Keirsbulck, L.
    JOURNAL OF APPLIED FLUID MECHANICS, 2016, 9 (03) : 1309 - 1319
  • [38] Quantification of Hemodynamic Wall Shear Stress in Patients with Bicuspid Aortic Valve Using Phase-Contrast MRI
    Barker, Alex J.
    Lanning, Craig
    Shandas, Robin
    ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (03) : 788 - 800
  • [39] Quantification of Hemodynamic Wall Shear Stress in Patients with Bicuspid Aortic Valve Using Phase-Contrast MRI
    Alex J. Barker
    Craig Lanning
    Robin Shandas
    Annals of Biomedical Engineering, 2010, 38 : 788 - 800
  • [40] Simultaneous Measurements of Vascular Strain and Wall Shear Stress in the Carotid Artery based on Vector Flow Imaging and Vessel Wall Tracking in Duplex Mode
    Xu, Wenlong
    Du, Yigang
    Liu, Yuxi
    An, Xing
    Lu, Zhao Ling
    Liu, Yanbo
    Li, Shuangshuang
    Cong, Longfei
    Zhu, Lei
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,