68Ga-Pentixafor PET/CT for In Vivo Imaging of CXCR4 Receptors in Glioma Demonstrating a Potential for Response Assessment to Radiochemotherapy: Preliminary Results

被引:2
|
作者
Waheed, Abdul [1 ]
Singh, Baljinder [1 ,6 ]
Watts, Ankit [1 ]
Kaur, Harneet [1 ]
Singh, Harmandeep [1 ]
Dhingra, Kirti [1 ]
Ahuja, Chirag [2 ]
Madan, Renu [3 ]
Singh, Apinderpreet [4 ]
Radotra, Bishan D. [5 ]
机构
[1] Postgrad Inst Med Educ & Res, Dept Nucl Med, Chandigarh, India
[2] Postgrad Inst Med Educ & Res, Dept Radiodiag & Imaging, Chandigarh, India
[3] Postgrad Inst Med Educ & Res, Dept Radiotherapy, Chandigarh, India
[4] Postgrad Inst Med Educ & Res, Dept Neurosurg, Chandigarh, India
[5] Postgrad Inst Med Educ & Res, Dept Histopathol, Chandigarh, India
[6] Postgrad Inst Med Educ & Res PGIMER, Dept Nucl Med, Sect 12, Chandigarh 160012, India
关键词
Ga-68-pentixafor PET/CT; CXCR receptors; glioblastoma multiforme; MR spectroscopy; radiochemotherapy; EMISSION-TOMOGRAPHY; CHEMOKINE RECEPTOR; RADIATION-THERAPY; RECURRENCE; DIFFERENTIATION;
D O I
10.1097/RLU.0000000000005073
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose : The aim of this study was to evaluate the diagnostic potential of Ga-68-pentixafor PET/CT for in vivo CXCR4 receptors imaging in glioma and its possible role in response assessment to radiochemotherapy (R-CT). Methods : Nineteen (12 men, 7 women) patients with glioblastoma multiforme (GBM) underwent Ga-68-pentixafor PET/CT, contrast-enhanced MR, and MR spectroscopy. Patients were divided in to 2 groups, that is, group I was the presurgical (n = 9) group in which the scanning was done before surgery, and PET findings were correlated with CXCR4 receptors' density. The group II was the postsurgical (n = 10) group in which the scanning was done before and after R-CT and used for treatment response evaluation. The quantitative analysis of Ga-68-pentixafor PET/CT evaluated the mean SUVmax, SUVmean, SUVpeak, and T/B values. MR spectroscopy data evaluated the ratios of tumor metabolites (choline, NAA, creatine). Results : Ga-68-Pentixafor uptake was noted in all (n = 19) the patients. In the group I, the mean SUVmax, SUVmean, SUVpeak, and T/B values were found to be 4.5 +/- 1.6, 0.60 +/- 0.26, 1.95 +/- 0.8, and 6.9 +/- 4.6, respectively. A significant correlation (P < 0.005) was found between SUVmean and choline/NAA ratio. Immunohistochemistry performed in 7/9 showed CXCR4 receptors' positivity (intensity 3(+); stained cells >50.0%). In the group II, the mean SUVmax at baseline was 4.6 +/- 2.1 and did not differ (4.4 +/- 1.6) significantly from the value noted at post-R-CT follow-up PET/CT imaging. At 6 months' clinical follow-up, 4 patients showed stable disease. SUVmax and T/B ratios at follow-up imaging were lower (3.70 +/- 0.90, 2.64 +/- 1.35) than the corresponding values (4.40 +/- 2.8; 2.91 +/- 0.93) noted at baseline. Six (6/10) patients showed disease progression, and the mean SUVmax, and T/B ratio in these patients were significantly (P < 0.05) higher than the corresponding values at baseline and also higher than that noted in the stable patients. Conclusions : Ga-68-Pentixafor PET/CT can be used for in vivo mapping of CXCR4 receptors in GBM. The technique after validation in a large cohort of patients may have added diagnostic value for the early detection of GBM recurrence and for treatment response evaluation.
引用
收藏
页码:e141 / e148
页数:8
相关论文
共 50 条
  • [31] Advances in PET Imaging of the CXCR4 Receptor: [68Ga]Ga-PentixaFor
    Lindenberg, Liza
    Ahlman, Mark
    Lin, Frank
    Mena, Esther
    Choyke, Peter
    SEMINARS IN NUCLEAR MEDICINE, 2024, 54 (01) : 163 - 170
  • [32] 68Ga-Pentixafor PET/CT demonstrating higher CXCR4 density in small cell lung carcinoma than in non-small cell variant
    Ankit Watts
    Baljinder Singh
    Rajender Basher
    Harmandeep Singh
    Amanjit Bal
    Rakesh Kapoor
    Sunil K. Arora
    Hans J. Wester
    B. R. Mittal
    D. Behera
    European Journal of Nuclear Medicine and Molecular Imaging, 2017, 44 : 909 - 910
  • [33] 68Ga-Pentixafor PET/CT demonstrating higher CXCR4 density in small cell lung carcinoma than in non-small cell variant
    Watts, Ankit
    Singh, Baljinder
    Basher, Rajender
    Singh, Harmandeep
    Bal, Amanjit
    Kapoor, Rakesh
    Arora, Sunil K.
    Wester, Hans J.
    Mittal, B. R.
    Behera, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 (05) : 909 - 910
  • [34] [68 Ga]Ga-CXCR4 PET/CT imaging in high-grade glioma for assessment of CXCR4 receptor expression
    Roustaei, Hessamoddin
    Vosoughi, Habibeh
    Askari, Emran
    Kalantari, Bagher Aziz
    Norouzbeigi, Nasim
    Anvari, Kazem
    Beheshti, Mohsen
    Aryana, Kamran
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 180
  • [35] Imaging Inflammation in Atherosclerosis with CXCR4-directed 68Ga-Pentixafor PET/CT - Correlation with 18F-FDG PET/CT
    Kircher, Malte
    Li, Xiang
    Kemmer, Luisa
    Schirbel, Andreas
    Buck, Andreas
    Wester, Hans
    Hacker, Marcus
    Lapa, Constantin
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [36] Imaging Inflammation in Atherosclerosis with CXCR4-Directed 68Ga-Pentixafor PET/CT: Correlation with 18F-FDG PET/CT
    Kircher, Malte
    Tran-Gia, Johannes
    Kemmer, Luisa
    Zhang, Xiaoli
    Schirbel, Andreas
    Werner, Rudolf A.
    Buck, Andreas K.
    Wester, Hans-Juergen
    Hacker, Marcus
    Lapa, Constantin
    Li, Xiang
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61 (05) : 751 - 756
  • [37] In vivo imaging and quantification of CXCR4 expression in lung cancer subtypes using 68Ga-Pentixafor PET/CT and Flow cytometry analysis: A single center and First Asian Experience
    Watts, Ankit
    Singh, Baljinder
    Dhanota, Ninjit
    Vohra, Mehak
    Kumar, Rajender
    Singh, Harmandeep
    Bal, Amanjit
    Kapoor, Rakesh
    Arora, Sunil
    Wester, Hans
    Radotra, Bishan
    Mittal, Bhagwant
    Behera, Digambar
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [38] 68Ga-pentixafor PET: clinical molecular imaging of chemokine receptor CXCR4 expression in multiple myeloma [68Ga-Pentixafor-PET: Klinische molekulare Bildgebung der Chemokinrezeptor-CXCR4-Expression beim multiplen Myelom]
    Avanesov M.
    Karul M.
    Derlin T.
    Der Radiologe, 2015, 55 (10): : 829 - 831
  • [39] Preclinical evaluation of 68Ga-pentixafor for PET imaging of CXCR4 expression in lymphoproliferative diseases and solid tumors: a comparison to 18F-FDG PET imaging
    Pan, Qingqing
    Luo, Yaping
    Yao, Shaobo
    Li, Fang
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [40] [68Ga]-Pentixafor PET/CT for CXCR4-Mediated Imaging of Vestibular Schwannomas
    Breun, Maria
    Monoranu, Camelia M.
    Kessler, Almuth F.
    Matthies, Cordula
    Loehr, Mario
    Hagemann, Carsten
    Schirbel, Andreas
    Rowe, Steven P.
    Pomper, Martin G.
    Buck, Andreas K.
    Wester, Hans-Juergen
    Emestus, Ralf-Ingo
    Lapa, Constantin
    FRONTIERS IN ONCOLOGY, 2019, 9