Analysis of the quality of industrialized coffee powder using the techniques of computed microtomography and x-ray fluorescence

被引:4
|
作者
Machado, Alessandra S. [1 ]
Silva, Aline de Sa S. [1 ]
de Araujo, Olga Maria Oliveira [1 ]
Santos, Ramon S. [2 ]
Leitao, Roberta G. [2 ]
dos Anjos, Marcelino J. [2 ]
de Oliveira, Davi F. [1 ]
Lopes, Ricardo T. [1 ]
机构
[1] Univ Fed Rio de Janeiro, Nucl Instrumentat Lab, Rio De Janeiro, Brazil
[2] Univ Estado Rio De Janeiro, Phys Inst, Rio De Janeiro, Brazil
关键词
commercial roasted ground coffee; computed microtomography; impurities; x-ray fluorescence; ETHIOPIAN COFFEE; SPECTROMETRY; DIFFERENTIATION; ADULTERATION; ORIGINS;
D O I
10.1002/xrs.3326
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The culture of coffee is very important in Brazilian scenery. Brazil is the world's largest coffee producer, responsible for 30% of the planet's production, and it is among the 15 largest coffee consuming nations. More and more, consumers look for better quality of coffee, and the presence of determinate composts would prejudice the health of the consumers. Therefore, this study suggests a method to identify and quantify commercially roasted ground coffee impurities/contaminants using computed microtomography (micro-CT) and x-ray fluorescence (XRF) techniques. A set of different commercially roasted ground coffees were investigated. The micro-CT results showed that most of the coffee powder samples analyzed showed some contaminant, and in a specific brand, the amount of contaminants was higher than 9%. The 3D data provided information about the size and shape of these contaminants. The XRF results showed the macro elements P, S, Cl, K, and Ca and the micro elements Mn, Fe, Cu, Zn, Rb, and Sr. The elemental concentrations are in agreement with the values reported in the literature, except for the same specific brand, where the values found were much higher. The combined data of both techniques showed that the amount of impurities/contaminants in the ground coffee results in an increase of the macro and micro nutrients and also modifies the flavor and fragrance of the product, leading to an overall poor quality of the final beverage.
引用
收藏
页码:303 / 311
页数:9
相关论文
共 50 条
  • [21] X-ray fluorescence microtomography: experiment and reconstruction
    Simionovici, A
    Chukalina, M
    Drakopoulos, M
    Snigireva, I
    Snigirev, A
    Schroer, C
    Lengeler, B
    Janssens, K
    Adams, F
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 304 - 310
  • [22] Investigating biomineralization using synchrotron based X-ray computed microtomography
    Armstrong, Ryan
    Ajo-Franklin, Jonathan
    GEOPHYSICAL RESEARCH LETTERS, 2011, 38
  • [23] Analysis of metallic archaeological artifacts by x-ray computed microtomography technique
    Machado, A. S.
    Silva, A. S. S.
    Campos, G. N.
    Gomes, C. S.
    Oliveira, D. F.
    Lopes, R. T.
    APPLIED RADIATION AND ISOTOPES, 2019, 151 : 274 - 279
  • [24] Imaging biofilm in porous media using X-ray computed microtomography
    Davit, Y.
    Iltis, G.
    Debenest, G.
    Veran-Tissoires, S.
    Wildenschild, D.
    Gerino, M.
    Quintard, M.
    JOURNAL OF MICROSCOPY, 2011, 242 (01) : 15 - 25
  • [25] Chemical and Structural Analysis of Rocks Using X-ray Fluorescence and X-ray Diffraction Techniques
    Sabri, Mohammed M.
    ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY, 2020, 8 (01): : 79 - 87
  • [26] Combined imaging system for X-ray fluorescence and transmission X-ray microtomography
    Ohigashi, T
    Watanabe, N
    Yokosuka, H
    Aoki, S
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 1352 - 1355
  • [27] Characterization of carbonate rocks through X-ray microfluorescence and X-ray computed microtomography
    Machado, Alessandra Silveira
    Santos, Ramon Silva
    Rodrigues, Amanda Goulart
    Borghi, Leonardo
    de Oliveira, Davi Ferreira
    dos Anjos, Marcelino Jose
    Lopes, Ricardo Tadeu
    X-RAY SPECTROMETRY, 2019, 48 (05) : 543 - 552
  • [28] X-ray fluorescence microtomography with a Wolter mirror system
    Watanabe, N
    Yamamoto, K
    Takano, H
    Ohigashi, T
    Yokosuka, H
    Aota, T
    Aoki, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 837 - 840
  • [29] X-ray fluorescence microtomography analyzing reference samples
    Pereira, G. R.
    Lopes, R. T.
    Anjos, M. J.
    Rocha, H. S.
    Perez, C. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (01): : 322 - 325
  • [30] On the challenges of greyscale-based quantifications using X-ray computed microtomography
    Zhang, Yulai
    Mostaghimi, Peyman
    Armstrong, Ryan T.
    JOURNAL OF MICROSCOPY, 2019, 275 (02) : 82 - 96