Power Level Control of Nuclear Power Plants During Load Following Operation Using Fractional Order Controller Based on a Modified Algorithm

被引:3
|
作者
Boghdady, Tarek A. [1 ]
Mahmoud, Mostafa [1 ]
Zahab, Essam Aboul [1 ]
Tag-Eldin, Elsayed [2 ]
Sayed, Mahmoud [1 ]
机构
[1] Cairo Univ, Fac Engn, Dept Elect Power Engn, Giza 12613, Egypt
[2] Future Univ Egypt, Fac Engn & Technol, New Cairo 11835, Egypt
关键词
Fractional order controller; manta ray foraging optimization; nuclear power plant; power level control; renewable energy resources; RAY FORAGING OPTIMIZATION; PID CONTROLLER; CORE POWER;
D O I
10.1109/ACCESS.2023.3336595
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Nuclear power can play an important role to achieve a secure clean energy transition. Output power control is considered an important issue with respect to nuclear power plants (NPPs) especially during load following operation mode. In this study, a scheduled fractional order proportional integral derivative (FOPID) controller is designed in order to track the desired reference power for a nuclear reactor in a NPP. Also, a modified manta ray foraging optimization (MMRFO) algorithm is proposed to tune the five parameters of the FOPID controller. The performance of the proposed algorithm is compared with several optimization techniques using 23 benchmark functions. The comparison shows that MMRFO has the best performance. The simulation of the FOPID controller tuned by the proposed MMRFO algorithm is performed using MATLAB/Simulink and its performance is compared with classic PID controller tuned by the MMRFO algorithm. Two different dynamic simulations during load following operation of a nuclear reactor are carried out. The first case study covers the short time operation of a nuclear reactor and the second case covers the long time operation. The simulation results show an acceptable performance with high degree of accuracy for the proposed FOPID controller tuned by the modified algorithm with very low overshoot, very low steady state error and proper control signal. Also, the stability of the proposed controller is also tested using Lyapunov stability criterion which indicates the stable operation for the proposed controller in the two cases. In addition, a sensitivity analysis has been accomplished which indicates the robustness of the controller.
引用
收藏
页码:134382 / 134403
页数:22
相关论文
共 50 条
  • [41] DC voltage control of active power filter based on fractional-order PIλ controller
    Wang, X. (xhwang@scut.edu.cn), 2013, Automation of Electric Power Systems Press (37):
  • [42] Avoidance of partial load operation at coal-fired power plants by storing nuclear power through power to gas
    Bailera, Manuel
    Lisbona, Pilar
    Romeo, Luis M.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2019, 44 (47) : 26063 - 26075
  • [43] Modelling and coordinated control for load following of nuclear power plant
    Xia, Hao
    Guo, Xiaoliang
    2022 41ST CHINESE CONTROL CONFERENCE (CCC), 2022, : 3527 - 3532
  • [44] Fractional order PID controller design for LFC in electric power systems using imperialist competitive algorithm
    Taher, Seyed Abbas
    Fini, Masoud Hajiakbari
    Aliabadi, Saber Falahati
    AIN SHAMS ENGINEERING JOURNAL, 2014, 5 (01) : 121 - 135
  • [45] Design of an ORBP-based fractional order controller for load frequency control in a multi-area power system with integration of RES
    Dinesh, T.
    Manjula, M.
    PRZEGLAD ELEKTROTECHNICZNY, 2024, 100 (09): : 100 - 105
  • [46] Adaptive neurofuzzy controller to regulate UTSG water level in nuclear power plants
    Munasinghe, SR
    Kim, MS
    Lee, JJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 421 - 429
  • [47] Radiating power tracking based on fractional order sliding mode controller
    Gou, Xuan
    Yin, Chun
    Chen, Kai
    Wang, Zengzeng
    Wang, Peng
    Wang, Houjun
    MEASUREMENT & CONTROL, 2022, 55 (7-8): : 674 - 683
  • [48] Peak-load and shock-load during the operation of public power plants
    Fleischer, W
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1936, 80 : 1243 - 1246
  • [49] Load frequency control problem in interconnected power systems using robust fractional PIλD controller
    Delassi, Abdelmoumene
    Arif, Salem
    Mokrani, Lakhdar
    AIN SHAMS ENGINEERING JOURNAL, 2018, 9 (01) : 77 - 88
  • [50] Load following approach for a VVER nuclear power plant using generic model control
    Rady, Khaled
    El-Metwally, Mahmoud Mohamed
    Abouelsoud, Ahmed
    Farrag, Mahmoud
    Kotb, Said
    INTERNATIONAL JOURNAL OF AUTOMATION AND CONTROL, 2022, 16 (3-4) : 489 - 502