Review of sub-synchronous interaction in wind integrated power systems: classification, challenges, and mitigation techniques

被引:13
|
作者
Verma, Neevatika [1 ]
Kumar, Narendra [1 ]
Gupta, Saket [1 ,5 ]
Malik, Hasmat [2 ,4 ]
Garcia Marquez, Fausto Pedro [3 ]
机构
[1] Delhi Technol Univ, Dept Elect Engn, Delhi 110042, India
[2] UTM, Fac Elect Engn, Dept Elect Power Engn, Johor Baharu 81310, Malaysia
[3] Univ Castilla La Mancha, Ingenium Res Grp, Ciudad Real 13071, Spain
[4] Graphic Era Deemed Be Univ, Dept Elect Engn, Dehra Dun 248002, India
[5] Bharati Vidyapeeths Coll Engn, Instrumentat & Control Engn Dept, New Delhi 110056, India
关键词
Damping controller; Doubly fed induction generator (DFIG); Series compensations; Sub-synchronous interactions (SSI); Sub-synchronous resonance (SSR); FED INDUCTION GENERATOR; SUBSYNCHRONOUS CONTROL INTERACTION; FEEDBACK LINEARIZATION; TORSIONAL INTERACTION; SERIES COMPENSATION; TRANSFER CAPABILITY; RESONANCE ANALYSIS; CONTROLLER-DESIGN; DAMPING CONTROL; SSR MITIGATION;
D O I
10.1186/s41601-023-00291-0
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Emerging sub-synchronous interactions (SSI) in wind-integrated power systems have added intense attention after numerous incidents in the US and China due to the involvement of series compensated transmission lines and power electronics devices. SSI phenomenon occurs when two power system elements exchange energy below the synchronous frequency. SSI phenomenon related to wind power plants is one of the most significant challenges to maintaining stability, while SSI phenomenon in practical wind farms, which has been observed recently, has not yet been described on the source of conventional SSI literature. This paper first explains the traditional development of SSI and its classification as given by the IEEE, and then it proposes a classification of SSI according to the current research status, reviews several mitigation techniques and challenges, and discusses analysis techniques for SSI. The paper also describes the effect of the active damping controllers, control scheme parameters, degree of series compensation, and various techniques used in wind power plants (WPPs). In particular, a supplementary damping controller with converter controllers in Doubly Fed Induction Generator based WPPs is briefly pronounced. This paper provides a realistic viewpoint and a potential outlook for the readers to properly deal with SSI and its mitigation techniques, which can help power engineers for the planning, economical operation, and future expansion of sustainable development.
引用
收藏
页数:26
相关论文
共 50 条
  • [11] Frequency Drift of Sub-Synchronous Oscillation in Wind Turbine Generator Integrated Power System
    Wang, Yang
    Du, Wenjuan
    Wang, Haifeng
    [J]. Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2020, 35 (01): : 146 - 157
  • [12] H∞ current damping control of DFIG based wind farm for sub-synchronous control interaction mitigation
    Wang, Yun
    Wu, Qiuwei
    Yang, Rong
    Tao, Guoqing
    Liu, Zhaoxi
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 98 : 509 - 519
  • [13] Sub-Synchronous Interaction Damping Control for DFIG Wind Turbines
    Leon, Andres E.
    Solsona, Jorge A.
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2015, 30 (01) : 419 - 428
  • [14] Susceptibility of Wind Turbines to Sub-synchronous Control and Torsional Interaction
    Badrzadeh, Babak
    Saylors, Steve
    [J]. 2012 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2012,
  • [15] Review and prospect of research on sub-synchronous oscillation mechanism for power system with wind power participation
    Xue, Ancheng
    Fu, Xiaoyu
    Qiao, Dengke
    Wang, Yongjie
    Wang, Jiawei
    [J]. Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2020, 40 (09): : 118 - 128
  • [16] Passive control strategy to mitigate sub-synchronous control interaction of DFIG-based integrated power systems
    Li, Shenghu
    Ye, Jianqiao
    Chen, Dong
    [J]. Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2023, 51 (11): : 77 - 85
  • [17] Sub-synchronous oscillation in wind farm integrated power system considering static var compensator
    Huang, Biyue
    Chen, Yahao
    Sun, Haishun
    Mao, Yujie
    Han, Yingsheng
    Wang, Dongze
    [J]. Qinghua Daxue Xuebao/Journal of Tsinghua University, 2021, 61 (05): : 446 - 456
  • [18] Interaction of sub-synchronous oscillation between wind turbine clusters in wind farm
    Xu, Yanhui
    Teng, Xianhao
    [J]. Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2020, 40 (09): : 156 - 162
  • [19] Sub-synchronous resonance mitigation via distributed power flow controller
    Khazaie, Javad
    Mokhtari, Maghsood
    Badkubi, Salman
    Khalilian, Mansour
    Nazarpour, Daryoush
    [J]. INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2013, 23 (06): : 751 - 766
  • [20] Sub-synchronous resonance in series compensated wind farm: A review
    Virulkar, V. B.
    Gotmare, G. V.