GaVe: A Webcam-Based Gaze Vending Interface Using One-Point Calibration

被引:4
|
作者
Zeng, Zhe [1 ]
Liu, Sai [1 ]
Cheng, Hao [2 ]
Liu, Hailong [3 ]
Li, Yang [4 ]
Feng, Yu [5 ]
Siebert, Felix Wilhelm [6 ]
机构
[1] Tech Univ Berlin, Berlin, Germany
[2] Univ Twente, Enschede, Netherlands
[3] Nara Inst Sci & Technol, Nara, Japan
[4] Karlsruhe Inst Technol, Karlsruhe, Germany
[5] Leibniz Univ Hannover, Hannover, Germany
[6] Tech Univ Denmark, Lyngby, Denmark
来源
JOURNAL OF EYE MOVEMENT RESEARCH | 2023年 / 16卷 / 01期
关键词
Human-computer interaction; gaze interaction; touchless; gaze; eye movement; eye tracking; usability; dwell time; EYE-MOVEMENTS;
D O I
10.16910/jemr.16.1.2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Gaze input, i.e., information input via eye of users, represents a promising method for con-tact-free interaction in human-machine systems. In this paper, we present the GazeVending interface (GaVe), which lets users control actions on a display with their eyes. The interface works on a regular webcam, available on most of today's laptops, and only requires a short one-point calibration before use. GaVe is designed in a hierarchical structure, presenting broad item cluster to users first and subsequently guiding them through another selection round, which allows the presentation of a large number of items. Cluster/item selection in GaVe is based on the dwell time, i.e., the time duration that users look at a given Clus-ter/item. A user study (N=22) was conducted to test optimal dwell time thresholds and com-fortable human-to-display distances. Users' perception of the system, as well as error rates and task completion time were registered. We found that all participants were able to quickly understand and know how to interact with the interface, and showed good performance, selecting a target item within a group of 12 items in 6.76 seconds on average. We provide design guidelines for GaVe and discuss the potentials of the system.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] One-point codes using places of higher degree
    Matthews, GL
    Michel, TW
    IEEE TRANSACTIONS ON INFORMATION THEORY, 2005, 51 (04) : 1590 - 1593
  • [32] One-point calibration for calibration-free laser-induced breakdown spectroscopy quantitative analysis
    Cavalcanti, G. H.
    Teixeira, D. V.
    Legnaioli, S.
    Lorenzetti, G.
    Pardini, L.
    Palleschi, V.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2013, 87 : 51 - 56
  • [33] Development of a hybrid mental spelling system combining SSVEP-based brain-computer interface and webcam-based eye tracking
    Lim, Jeong-Hwan
    Lee, Jun-Hak
    Hwang, Han-Jeong
    Kim, Dong Hwan
    Im, Chang-Hwan
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2015, 21 : 99 - 104
  • [34] ONE-POINT RECALIBRATION OF HETEROGENEOUS ENZYME IMMUNOASSAYS WITH NON-LINEAR CALIBRATION CURVES
    MEYER, HD
    KELLER, H
    CLINICAL CHEMISTRY, 1988, 34 (01) : 113 - 117
  • [35] Evaluation of One-Point Calibration for Cuffless BP Wearable Sensor Devices: Stiffness Index
    Xu, Hongqiang
    Heydari, Fatemeh
    Rathnayaka, Asanka
    Wu, Fan
    Yuce, Mehmet Rasit
    IEEE SENSORS JOURNAL, 2024, 24 (07) : 11374 - 11385
  • [36] DESIGN, CHARACTERIZATION, AND ONE-POINT IN-VIVO CALIBRATION OF A SUBCUTANEOUSLY IMPLANTED GLUCOSE ELECTRODE
    CSOREGI, E
    QUINN, CP
    SCHMIDTKE, DW
    LINDQUIST, SE
    PISHKO, MV
    YE, L
    KATAKIS, I
    HUBBELL, JA
    HELLER, A
    ANALYTICAL CHEMISTRY, 1994, 66 (19) : 3131 - 3138
  • [37] Development of a Hybrid Mental Speller Combining EEG-Based Brain-Computer Interface and Webcam-Based Eye-Tracking
    Lee, Jun-Hak
    Lim, Jeong-Hwan
    Hwang, Han-Jeong
    Im, Chang-Hwan
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 2240 - 2242
  • [38] A CMOS Temperature Sensor with a Maximum Accuracy of 1.6 °C after One-Point Calibration
    Chen, Chun-Chi
    Liu, Keng-Chih
    Lin, Shih-Hao
    INDUSTRIAL INSTRUMENTATION AND CONTROL SYSTEMS II, PTS 1-3, 2013, 336-338 : 216 - 220
  • [39] Reducing matrix effects on the quantification of Ca, Mg, and Fe in soybean leaf samples using calibration-free LIBS and one-point calibration
    Leva Borduchi, Luis Carlos
    Bastos Pereira Milori, Debora Marcondes
    Meyer, Mauricio Conrado
    Villas-Boas, Paulino Ribeiro
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2022, 198
  • [40] Reset technique based on velocity reference and one-point position
    Gao, Z.-Y. (gaozy@mails.tsinghua.edu.cn), 2013, Editorial Department of Journal of Chinese Inertial Technology (21):