摘要
The insulation performance improvement of transformer oil under dc voltage is of great significance in reducing the fault of the converter transformer. The nano-modified transformer oil has excellent electrical properties, but the research on corona discharge characteristics under dc voltage is insufficient. This article studied the corona discharge characteristics of SiO2 and TiO2 nanofluids (NFs, transformer oil with SiO2 and TiO2 nanoparticles addition, respectively) and pure oil by combining experiments with simulation. A series of dc corona discharge tests were carried out under the needle-plate electrode, and the pulse current was used to characterize the corona discharge level. The electron mobility was obtained through the surface potential decay method, and positive and negative ions' mobility was measured using the polarity reversal method. Then, the effects of the mobility of electrons, negative, and positive ions on the distribution of space charge and electric field in transformer oil were analyzed, respectively. The mechanism of nanoparticles regulating carrier mobility to improve the insulation performance of transformer oil was revealed. The result is of great theoretical significance and practical value for promoting and applying in advanced insulating liquids in power transformers.
引用
收藏
页码:3593 / 3600
页数:8
相关论文
共 50 条
  • [31] Effect of DC Voltage Ramp Rate on Breakdown in Ferrofluid Based on Transformer Oil
    Bartko, P.
    Rajnak, M.
    Cimbala, R.
    Kolcunova, I
    Paulovicova, K.
    Timko, M.
    Kopcansky, P.
    Kurimsky, J.
    ACTA PHYSICA POLONICA A, 2020, 137 (05) : 970 - 972
  • [32] Breakdown Characteristics of Typical Model in Transformer Oil under AC and DC mixed Voltage
    Guan Lan
    Li Bo
    Cheng Huanchao
    Li Jinzhong
    Li Guangfan
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 403 - 406
  • [33] Simulation research on the force and motion of solid particles in transformer oil under DC voltage
    Meng, Xuan
    Guo, Ruochen
    Hou, Jiachen
    Wang, Haotian
    Li, Junhao
    ENERGY REPORTS, 2022, 8 : 967 - 972
  • [34] An experimental study on electrohydrodynamically induced silicon oil vapor flow under DC corona discharge
    Ohyama, R
    Fukumoto, M
    2004 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2004, : 126 - 129
  • [35] Simulational study on streamer discharge in transformer oil under positive nanosecond pulse voltage
    Li Yuan
    Mu Hai-Bao
    Deng Jun-Bo
    Zhang Guan-Jun
    Wang Shu-Hong
    ACTA PHYSICA SINICA, 2013, 62 (12)
  • [36] Study on dielectric surface discharge in transformer oil under high voltage nanosecond pulse
    Wang, J
    Zhou, YX
    Yan, P
    Huang, WL
    Li, GJ
    Zhang, SC
    Sun, GS
    JOURNAL OF ELECTROSTATICS, 2005, 63 (6-10) : 665 - 671
  • [37] Characteristics of corona discharge in an Icicle/Iced-plate electrode system under negative DC voltage
    Farzaneh, M.
    Zhang, J.
    Yu, D.
    Sun, C.
    Sima, W.
    Shu, L.
    ICPASM 2005: PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 2006, : 48 - +
  • [38] The Correlation between Audible Noise and Corona Discharge on an Overhead Line Conductor under Positive DC Voltage
    Zhang, Xu
    Emersic, Christopher
    Lian, Chengxing
    Cotton, Ian
    2021 96TH IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP 2021) / 16TH IEEE NANOTECHNOLOGY MATERIALS AND DEVICES CONFERENCE (IEEE NMDC 2021), 2021, : 586 - 589
  • [39] Research on the Factors Influencing the UV Detection of Corona Discharge Under Combined AC-DC Voltage
    Huang, Jiahao
    Zhang, Bo
    Xie, Guiquan
    Wang, Chentao
    Zhou, Xiangsheng
    Shi, Yanhui
    Yuan, Hai
    Wang, Qingjun
    Kuang, Jianrong
    Zhu, Yunfeng
    Tang, Li
    Zhao, Hanghang
    2022 4TH INTERNATIONAL CONFERENCE ON SMART POWER & INTERNET ENERGY SYSTEMS, SPIES, 2022, : 43 - 48
  • [40] Streamer Discharge Propagation and Branching Characteristics in Transformer Oil under AC Voltage: Partial Discharge and Light Emission
    Li, Yuan
    Wen, Jia Ye
    Liang, Yu
    Wu, Jiang
    Qin, Shaorui
    Zhang, Guan-Jun
    2017 IEEE 19TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL), 2017,