共 50 条
Racial Differences in Detection of Glaucoma Using Retinal Nerve Fiber Layer Thickness and Bruch Membrane Opening Minimum Rim Width
被引:5
|作者:
El-Nimri, Nevin W.
[1
,2
,3
]
Moghimi, Sasan
[1
,2
,3
]
Nishida, Takashi
[1
,2
,3
]
Yarmohammadi, Adeleh
[1
,2
,3
]
Zangwill, Linda M.
[1
,2
,3
]
Hou, Huiyuan
[1
,2
,3
]
Proudfoot, James
[1
,2
,3
]
Walker, Evan
[1
,2
,3
]
Fazio, Massimo A.
[4
]
Girkin, Christopher A.
[4
]
Liebmann, Jeffrey M.
[5
]
Weinreb, Robert N.
[1
,2
,3
]
机构:
[1] Univ Calif San Diego, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Shiley Eye Inst, La Jolla, CA 92093 USA
[3] Univ Calif San Diego, Viterbi Family Dept Ophthalmol, La Jolla, CA 92093 USA
[4] Univ Alabama Birmingham, Dept Ophthalmol & Visual Sci, Heersink Sch Med, Birmingham, AL USA
[5] Columbia Univ Irving Med Ctr, Edward S Harkness Eye Inst, Dept Ophthalmol, Bernard & Shirlee Brown Glaucoma Res Lab, New York, NY USA
关键词:
OPEN-ANGLE GLAUCOMA;
OPTICAL COHERENCE TOMOGRAPHY;
SCANNING LASER OPHTHALMOSCOPY;
OCULAR HYPERTENSION TREATMENT;
NEURORETINAL RIM;
NORMATIVE DATABASE;
DISC TOPOGRAPHY;
PREVALENCE;
WHITE;
RACE;
D O I:
10.1016/j.ajo.2022.10.010
中图分类号:
R77 [眼科学];
学科分类号:
100212 ;
摘要:
PURPOSE: To compare the sensitivities and specificities of the retinal nerve fiber layer thickness (RNFLT) and Bruch membrane opening minimum rim width (BMOMRW) reference database-based criteria for detection of glaucoma in individuals of European descent (ED) and individuals of African descent (AD). DESIGN: Comparative diagnostic analysis by race METHODS: 382 eyes of 255 glaucoma patients (ED = 170, AD = 85) and 94 eyes of 50 healthy individuals (ED = 30, AD = 20) with global and sectoral RNFLT and BMO-MRW measured with Spectralis optical coherence tomography (OCT) were included. Six diagnostic criteria were evaluated: global measurement below the 5th or 1st percentile, =1 of the 6 sector measurements below the 5th or 1st percentile, and superotemporal (ST) and/or inferotemporal (IT) measurement below the 5th or 1st percentile. The sensitivities and specificities of these measurements for detection of glaucoma were compared using bootstrapping methods. RESULTS: ST and/or IT RNFLT below the 5th percentile has the best performance for detection of glaucoma among RNFLT classifications with a sensitivity (95% CI) of 89.5% (86.1, 92.5) and specificity of 87.2% (77.8, 95.1). In AD individuals, sensitivities of ST and IT RNFLT and BMO-MRW measurements below the 5th percentile criteria were lower than in ED individuals (RNFLT: 83.7% vs 92.5%, and BMO-MRW: 72.1% vs 88.5%, respectively), as well as specificities (AD RNFLT: 73.7% and BMO-MRW: 89.5% vs ED RNFLT: 96.4% and BMO-MRW: 98.2%, respectively). CONCLUSIONS: RNFLT and BMO-MRW had consistently lower diagnostic performance in AD individuals compared with ED individuals. BMO-MRW criteria might fail to detect as many as one-third of eyes with glaucoma, specifically in AD individuals. With the current reference database, RNFLT, and especially BMO-MRW, criteria are not adequate for diagnosing glaucoma in AD individuals. (Am J Ophthalmol 2023;246: 223-235. (c) 2022 Elsevier Inc. All rights reserved.)
引用
收藏
页码:223 / 235
页数:13
相关论文